SCOTECH muaj VPI qhuav hom transformer mus txog 20 MVA 35 kV
Txhua lub tshuab hluav taws xob tuaj yeem raug teeb tsa nyob ib puag ncig ntawm txoj haujlwm hluav taws xob, kev teeb tsa kev teeb tsa, kev xav tau cua txias, kev tiv thaiv thaiv, thiab kev saib xyuas kev xav tau. Qhov no tso cai rau cov neeg yuav khoom los ntawm VPI transformer uas haum rau lawv cov kev ua haujlwm tau teev tseg thiab cov kev xav tau ntawm qhov project es tsis yog cia siab rau tus qauv teeb tsa.
VPI Transformer Project Kev Paub thoob ntiaj teb
Xauj peb cov kev xaiv ntawm VPI transformer tej yaam num, txhua tus nrog cov ntaub ntawv ntxaws kev tshawb fawb, tso cai rau cov neeg yuav khoom
intuitively nkag siab txog peb cov kev paub dhau los ntawm kev tuav ntau yam kev qhia tshwj xeeb thiab cov kev xav tau ntawm qhov project.
VPI Qhuav Hom Transformer Specifications
|
|
Parameter |
Specification |
|
Rated zog |
100 kVA-20 MVA |
|
|
Rated rwb thaiv tsev Level |
Mus txog 35 kV |
|
|
Rated Zaus |
50 / 60 Hz |
|
|
Rwb thaiv tsev Class |
A, E, B, F, H |
|
|
Cov qauv siv tau |
IEC, ANSI/IEEE, NEMA, CSA, GB, thiab lwm yam. |
|
|
Txias |
Ntuj cua txias; yuam kom txias ntawm kev thov |
|
|
Winding Temperature nce |
80℃/ 115℃/ 150 degree |
|
|
Kev teeb tsa |
Sab hauv; sab nraum zoov ntawm kev thov |
|
|
Kev Tiv Thaiv Kev Tiv Thaiv |
NEMA Hom 1, 12, 3R, 4, 4X; adaptable IP ntsuam xyuas |
|
|
Sab nraum zoov Enclosure |
Txog IP44 raws li kev thov |
|
|
Winding kev twb kev txuas |
Dyn 11, Dyn1, Ddo, Dyn5, lossis customized |
Transformer Configurations & Muaj Accessories
SCOTECH muaj cov khoom siv hloov pauv tau yooj yim thiab kev teeb tsa kev xaiv kom phim qhov sib txawv
hluav taws xob, kev saib xyuas, kev tiv thaiv, thiab kev teeb tsa kev xav tau.
Lub log
Cov log tuaj yeem muab los ua kom yooj yim hloov pauv qhov chaw, txav mus los, thiab teeb tsa qhov xav tau.
Electrostatic Shield
Ib qho hluav taws xob tiv thaiv hluav taws xob muaj rau cov ntawv thov uas xav tau kev tswj hwm kev sib txuas ntxiv thiab cov suab nrov hluav taws xob.
Tam sim no Transformer
Tam sim no transformers muaj rau cov ntawv thov uas yuav tsum tau ntsuas tam sim no, saib xyuas, lossis kev tiv thaiv kev ua haujlwm.
Winding Temperature Indicator
Winding qhov ntsuas kub tuaj yeem ua ke rau kev ntsuas kub thiab tswj kev ua haujlwm.
OLTC
On-load kais hloov pauv tuaj yeem muab rau cov haujlwm uas yuav tsum tau muaj kev tswj hwm hluav taws xob raws li kev ua haujlwm, raws li kev tsim cov khoom siv hluav taws xob.
Marshalling Box
Lub thawv marshalling tuaj yeem muab los muab kev sib txuas hauv nruab nrab rau kev saib xyuas, tswj, thiab kev tiv thaiv circuits.
Vacuum Pressure Impregnation rau Reliable Winding Insulation
VPI, lossis Vacuum Pressure Impregnation, yog txheej txheem rwb thaiv tsev uas hloov pauv windings raug kho.
nyob rau hauv kev tswj lub tshuab nqus tsev thiab siab ua ntej kho. Kev kho lub tshuab nqus tsev tshem tawm cov cua nkag thiab
noo noo los ntawm rwb thaiv tsev qauv, thaum resin impregnation nyob rau hauv voids
thiab bonds lub rwb thaiv tsev system thaum kho.
Kev kho lub tshuab nqus tsev
Lub winding yog muab tso rau hauv kev tswj lub tshuab nqus tsev kom tshem tawm cov cua nkag thiab ya raws los ntawm cov qauv rwb thaiv tsev, npaj cov winding rau resin impregnation.
Siab Impregnation
Insulating resin yog qhia nyob rau hauv kev tswj lub siab, tso cai rau nws nkag mus rau ntawm conductors thiab mus rau hauv lub winding rwb thaiv tsev qauv kom zoo ib yam impregnation.
Kho
Tom qab impregnation, lub winding yog kho raws li kev tswj xyuas kom stabilize lub rwb thaiv tsev system thiab muab cov neeg kho tshuab thiab hluav taws xob kev ncaj ncees.
Consolidated Insulation Structure
Cov txheej txheem VPI ua tiav tsim ib qho kev sib koom ua ke winding rwb thaiv tsev nrog txo cov voids sab hauv thiab txhim kho kev sib txuas ntawm cov khoom siv winding thiab rwb thaiv tsev, txhawb kev ua haujlwm ruaj khov nyob rau hauv hluav taws xob thiab thermal stresses.
VPI Dry Type Transformers rau ntau hom hluav taws xob siv
VPI qhuav hom transformers yog siv thoob plaws hauv kev lag luam, kev lag luam, kev tsim kho vaj tse, thiab kev siv hluav taws xob ntsig txog hluav taws xob
qhov twg txhim khu kev qha fais fab thiab roj-dawb transformer tsim yuav tsum tau.

Tsev High-Rise
VPI qhuav hom transformers tuaj yeem siv rau kev tsim hluav taws xob faib hluav taws xob hauv kev tsim kho siab, kev lag luam yees, thiab cov tsev loj nyob hauv qhov chaw nyob sab hauv tsev thiab qhov kev xav txog kev nyab xeeb hluav taws yog qhov tseem ceeb.

Airports & Tsheb thauj mus los
Haum rau lub tshav dav hlau terminals, rail chaw, metro systems, thiab lwm yam kev thauj mus los infrastructure yuav tsum tau siv hluav taws xob faib rau lub tsev tseem ceeb thiab chaw loads.

Chaw nres tsheb fais fab
Siv nyob rau hauv pab fais fab thiab faib tshuab nyob rau hauv lub hwj chim tsim chaw, nrog transformer specifications configured raws li cov nroj tsuag hluav taws xob system thiab kev khiav hauj lwm yuav tsum tau.

Chaw Ua Lag Luam
Tsim nyog rau cov khw muag khoom, chaw ua haujlwm, tsev so, thiab lwm lub tsev lag luam uas xav tau cov khoom siv hluav taws xob muaj txiaj ntsig zoo hauv thaj chaw nyob.

Cov Khoom Siv Muaj
Siv rau hauv cov chaw tsim khoom, cov chaw tsim khoom, cov chaw ua haujlwm, thiab lwm yam kev teeb tsa kev lag luam uas cov transformers tuaj yeem raug cuam tshuam rau qhov sib txawv load profiles thiab xav tau kev ua haujlwm.

Infrastructure Projects
Haum rau pej xeem infrastructure, cov chaw siv hluav taws xob, cov chaw zov me nyuam, thiab lwm cov tshuab hluav taws xob uas xav tau cov ntawv thov tshwj xeeb qhuav hom transformer configurations.
Q: VPI transformer txawv li cas los ntawm cam khwb cia coil transformer?
A: Qhov sib txawv tseem ceeb yog cov tshuab hluav taws xob rwb thaiv tsev. VPI qhuav hom transformer siv lub tshuab nqus tsev siab impregnation rau impregnate lub rwb thaiv tsev winding nrog resin, thaum lub cam khwb cia coil transformer siv epoxy resin los encapsulate lub windings.
Q: SCOTECH puas tuaj yeem tsim VPI transformers raws li qhov project specifications?
A: Yog. Kev cai VPI qhuav hom transformers tuaj yeem teeb tsa raws li qhov project-specific hluav taws xob, mechanical, installation, tiv thaiv, enclosure, thiab accessories yuav tsum tau.
Q: Cov duab kos duab puas tuaj yeem muab ua ntej ntau lawm?
A: Kev kos duab kos duab tuaj yeem muab rau qhov project technical review thiab kev sib koom ua ke raws li kev pom zoo ntawm kev hloov pauv. Cov duab kos tuaj yeem suav nrog kev teeb tsa dav dav, qhov ntev, qhov chaw davhlau ya nyob twg, kev teeb tsa hauv tsev, khoom siv, thiab lwm yam cuam tshuam.
Q: SCOTECH puas tuaj yeem muab kev txhawb nqa thaum lub sijhawm tshwj xeeb?
A: Yog. Peb pab pawg kws tshaj lij tuaj yeem tshuaj xyuas cov khoom siv hluav taws xob, cov khoom siv hluav taws xob, cov khoom siv hauv tsev, cov khoom siv, thiab cov txheej txheem kev teeb tsa thaum lub sij hawm hais lus thiab engineering theem los pab kom paub meej tias qhov tsim nyog tsim ua ntej ntau lawm.
Q: Puas tuaj yeem VPI transformers tsim rau qhov chaw teeb tsa tsawg?
A: Yog. Muaj qhov chaw nruab yog ib qho tseem ceeb rau kev txiav txim siab thaum lub sij hawm transformer engineering. Cov neeg yuav khoom tuaj yeem muab qhov ntev ntawm chav tsev, kev txwv kev nkag mus, kev nkag mus rau cable, thiab cov ntaub ntawv nyob ib puag ncig, yog li cov khoom siv hluav taws xob hloov pauv tuaj yeem ntsuas raws li.
Q: Puas yog VPI transformer xav tau qhov cua tshwj xeeb?
A: VPI transformers yog hom hloov pauv qhuav thiab tsis tas yuav muaj roj ntim. Txawm li cas los xij, cov cua kub txaus thiab qhov cua yuav tsum tau txiav txim siab raws li qhov ntsuas qhov ntsuas hluav taws xob, qhov poob, qhov kub thiab txias, qhov chaw kaw, thiab ib puag ncig kev teeb tsa.
Nrhiav rau Cast Coil Dry Type Transformers?
SCOTECH kuj tseem tsim cov cam khwb cia coil qhuav hom transformers raws li lwm txoj kev qhuav-hom transformer tov rau tej yaam num uas yuav tsum tau cam khwb cia resin rwb thaiv tsev. Cam khwb cia coil transformers feature epoxy resin-encapsulated windings thiab tuaj yeem teeb tsa rau ntau lub peev xwm, qhov hluav taws xob, cua txias, kaw, thiab kev tiv thaiv.
Yog tias koj qhov project xav tau kev tsim kho rwb thaiv tsev sib txawv lossis kev tiv thaiv ib puag ncig, tshawb xyuas peb cov Cast Coil Dry Type Transformer kev daws teeb meem los sib piv cov teeb tsa muaj thiab nrhiav kev xaiv uas zoo tshaj plaws rau koj daim ntawv thov.
VPI Dry Type Transformer Manufacturing Process
Los ntawm cov txheej txheem tseem ceeb thiab winding rau VPI rwb thaiv tsev kho, sib dhos, thiab kev tshuaj xyuas zaum kawg, peb tswj txhua tus
manufacturing theem raws li kev pom zoo transformer tsim thiab qhov project yuav tsum.

Core Processing
Cov tub ntxhais transformer yog tsim los ntawm high-permeability, grain-oriented txias-kuav los tiag silicon steel (CRGO) los pab txhawb kev sib nqus ua tau zoo thiab tswj cov tub ntxhais poob. Cov tub ntxhais tau txais kev txhawb nqa tag nrho, qhov tsis muaj qhov kev tsim kho nrog kev siv banding, muab cov tub ntxhais sib dhos ua tau zoo thiab muaj tseeb yam tsis muaj qhov drilled hauv cov laminations.

HV & LV Winding
Lub HV winding siv cov qauv txuas txuas ntxiv rau kev ua kom muaj cua sov kom zoo thiab muaj peev xwm ua kom muaj peev xwm tshaj, thaum LV winding txais cov ntawv ci winding rau kev faib khoom kub ntau dua, txhim kho winding stability, thiab txhim khu kev tiv thaiv luv luv.

Precision Rwb thaiv tsev thiab Coil Assembly
Lub HV thiab LV windings tau sib sau ua ke nrog cov txheej txheem rwb thaiv tsev thiab kev txhawb nqa. Hluav taws xob clearances, winding positioning, mechanical fixing, and insulation interfaces are controlled as the transformer design before the coils mus rau VPI kho theem.

VPI rwb thaiv tsev kho mob
Tom qab precision coil sib dhos, cov windings nkag mus rau VPI kho theem raws li cov txheej txheem pom zoo. Nqus, resin impregnation, thiab curing tej yam kev mob yog tswj nyob rau hauv cov kev kho mob los xyuas kom meej kev ua tau zoo ntawm winding rwb thaiv tsev system.

Core, Windings & Component Integration
Tom qab kev kho thiab kho VPI, cov kev kho cua sov tau koom ua ke nrog cov tub ntxhais transformer thiab lwm yam tsim. Kev sib txuas, rwb thaiv tsev, terminals, enclosure Cheebtsam, thiab cov khoom siv tshwj xeeb tau sib sau ua ke raws li kev pom zoo transformer configuration

Enclosure & Accessory Assembly
Cov ntaub thaiv npog thiab cov khoom siv tshwj xeeb tau sib sau ua ke raws li qhov xav tau kev teeb tsa thiab kev tiv thaiv kev teeb tsa. Raws li qhov yuav tsum tau ua, cov kev xaiv muaj xws li lub log, tam sim no transformers, OLTC, electrostatic shields, winding kub ntsuas, marshalling thawv, thiab lwm yam accessories.
VPI Dry Type Transformer Testing & Quality Assurance
Ua ntej shipping tiav lawm transformers, peb ua niaj hnub soj ntsuam thiab kev ntsuam xyuas raws li lub
xaiv cov qauv thiab qhov project specifications los xyuas kom meej tias txhua VPI qhuav-hom transformer
ua tau raws li cov kev cai hluav taws xob, rwb thaiv tsev, thiab qhov ntev.
Kev tshuaj xyuas kev tsim khoom
Cov txheej txheem tsim khoom tseem ceeb raug tshuaj xyuas los txheeb xyuas cov tub ntxhais sib dhos, kev tsim kho winding, kev kho rwb thaiv tsev, kev sib dhos tshuab, thiab kev teeb tsa cov khoom tiv thaiv kev pom zoo tsim thiab tsim khoom.
Kev kuaj hluav taws xob
Nyob ntawm qhov kev qhia tshwj xeeb ntawm lub tshuab hluav taws xob thiab cov qauv siv tau, kev sim muaj xws li winding resistance, lem ratio, tsis muaj load poob thiab tam sim no, load poob thiab impedance, thov voltage, thiab induced voltage tests.
Insulation thiab Performance Verification
Kev ntsuas hluav taws xob ntsig txog thiab kev ua haujlwm tau ua raws li kev tsim qauv thiab kev sim ntsuas cov qauv. Cov kev ntsuam xyuas muaj xws li rwb thaiv tsev tiv thaiv, ib feem ntawm qhov tso tawm, kub nce, thiab lwm yam kev xeem.
Kev soj ntsuam zaum kawg
Ua ntej tso tawm rau cov khoom xa tuaj, qhov ua tiav transformer raug kuaj xyuas rau tag nrho cov khoom sib dhos, qhov ntev, kev sib txuas, cov khoom siv, kev teeb tsa enclosure, cov ntaub ntawv npe, thiab cov kev cai tshwj xeeb.
Tau txais Daim Ntawv Tso Cai ntawm VPI Dry Type Transformer
Thov sau daim foos, thiab ib tus ntawm peb pab neeg yuav hu rau koj hauv 24 teev.

Jiangshan Scotech Electrical Co., Ltd yog ib qho ntawm cov ua lag luam thiab cov neeg muag khoom ntawm vpi qhuav hom transformer hauv Suav teb. Peb sov siab txais tos koj mus yuav tus nqi-npaum vpi qhuav hom transformer muag ntawm no los ntawm peb lub hoobkas. Yog tias koj muaj lus nug txog kev hais lus lossis cov duab kos, thov koj xa email tuaj rau peb.