Dab tsi yog Hluav Taws Xob Substation

Voltage Transformation thiab Fais Fais Distribution
Substations theem voltage nce lossis nqis kom ntseeg tau tias muaj hluav taws xob sib kis tau ntev thiab muaj kev nyab xeeb rau cov neeg siv kawg, txo qis zog poob thoob plaws hauv lub network.
Kev Tiv Thaiv thiab Tswj Cov Khoom Siv Hluav Taws Xob
Los ntawm kev tiv thaiv relays, Circuit Court breakers, thiab tswj systems, substations ntes faults, cais cov seem txawv txav, thiab tiv thaiv cov khoom tseem ceeb kom muaj kev ruaj ntseg thiab ua hauj lwm kev ruaj ntseg.
Saib xyuas, Automation, thiab System Integration (SCADA)
Cov chaw ua haujlwm niaj hnub no tau nruab nrog kev saib xyuas thiab kev sib txuas lus uas ua kom muaj sijhawm tiag - cov ntaub ntawv tau txais, kev tswj chaw taws teeb, thiab kev sib koom ua ke nrog SCADA platforms, txhim kho kev ua haujlwm tau zoo thiab kev cia siab ntawm daim phiaj.
Peb Substation Transformer Hom
- Peb muab cov kev daws teeb meem substation tiav - los ntawm lub tswv yim mus rau commissioning - kom tau raws li qhov kev thov loj hlob rau kev txhim khu kev qha, muaj kev nyab xeeb, thiab kev faib hluav taws xob zoo.
- Txawm hais tias rau cov khoom siv hluav taws xob, cov neeg siv kev lag luam, cov chaw tsim hluav taws xob txuas ntxiv mus, lossis cov kev sib txuas ua ke, peb xa cov tshuab ua haujlwm uas ua raws li IEC, IEEE, ANSI, CSA thiab cov qauv siv hluav taws xob hauv cheeb tsam.
- Txhua hom substation tuaj yeem ua raws li qhov yuav tsum tau muaj qhov ntsuas hluav taws xob, muaj peev xwm, thiab teeb tsa kom ua tau raws li cov qauv hauv zos thiab qhov project.
- Unit Substation
Hloov pauv - Compact substation
Hloov pauv - Containerized Substation
Hloov pauv - Tsheb -mounted mobile
Substation Transformer
Unit Substation Transformer
Chav tsev substation transformer yog ib qho ua ntej- sib dhos, compact fais fab faib chav tsev uas nqis los nruab nrab- hluav taws xob hluav taws xob hluav taws xob kom nyab xeeb, siv tau hluav taws xob. Nws nyob ze -coupled design integrates transformer with the first and secondary switchgear near the load, minimizing cabling and bus lengths, txo hwj chim poob, txhim kho voltage tswj, thiab pab txhawb kev pab cuam.
- Mus txog 10 MVA 34.5 kV
- Rated zog mus txog 10 MVA
- Rated rwb thaiv tsev theem mus txog 161 kV
- Kev kub ceev: 55 °, 65 °, 55/65 °, 45 °
Custom Features
- Electrostatic shielding los txo kev cuam tshuam.
- High-qib tiv thaiv corrosion (C5-M, marine/industrial) thiab seismic-resistant design.
- Kev cai bushing txoj haujlwm thiab xaim (sab saum toj / sab nkag, qhib tshwj xeeb).
- Ceev-nruab tsim nrog kiv cua qhib, nqa cov ntsiab lus, thiab ceev hauv av terminals.
- Tsawg- suab nrov tsim raws li cov neeg siv khoom xav tau.
- Tshwj xeeb impedance, kam rau ua, thiab K-factor designs rau txhim kho harmonic thiab nonlinear load tuav.
- Txhawb kua- puv, qhuav- hom, thiab tshwj xeeb transformer tsim rau cov ntawv thov tshwj xeeb

Compact Substation Transformer
Lub chaw ua haujlwm me me, tseem hu ua prefabricated substation, yog lub Hoobkas - sib dhos, tag nrho cov khoom siv hluav taws xob xa hluav taws xob uas sib koom ua ke siab -voltage switchgear, transformers, thiab qis- cov khoom siv hluav taws xob rau hauv ib qho qauv compact. Tsim los rau kev hloov pauv hluav taws xob zoo thiab kev faib tawm, nws muaj lub zog hlau thaiv nrog ntau yam kev tiv thaiv, ua rau nws tsim nyog rau ob qho tib si sab hauv tsev thiab sab nraum zoov kev teeb tsa hauv thaj chaw, kev lag luam, thiab kev lag luam.
- Txog 20000 KVA 72 kV
- Transformer muaj peev xwm Tsawg dua lossis sib npaug li 20000 KVA
- Rated voltage: 12 - 72 kV
- Kev tiv thaiv kab mob: IP54
- Qhov siab tshaj plaws: 5000 meters
- Kev saib xyuas keeb kwm yav dhau los ua kom muaj tseeb - lub sijhawm saib xyuas cov ntsiab lus tseem ceeb, suav nrog kev sib cuag ntawm qhov kub thiab txias, rwb thaiv tsev ib nrab tawm, thiab lub teeb arc.
- Ntau cov txheej txheem rwb thaiv tsev tau txais kev pom zoo, xws li cov khoom siv hluav taws xob zoo ib puag ncig, rwb thaiv tsev cua, rwb thaiv tsev, thiab ib nrab- rwb thaiv tsev.

Containerized Substation Transformer
Lub thawv substation transformer yog ib qho ua ntej- sib sau ua ke, cov khoom siv hluav taws xob hloov pauv uas nyob nruab nrab- thiab qis-voltage switchgear, transformers, thiab cov cuab yeej pabcuam hauv lub thawv steel. Tsim los rau kev xa tawm sai, kev thauj mus los yooj yim, thiab kev teeb tsa turnkey, nws muab kev ntseeg siab, huab cua- tiv thaiv hluav taws xob daws teeb meem rau qhov chaw ib ntus, kev teeb tsa sab nraum zoov, cov phiaj xwm kev lag luam, thiab lub luag haujlwm- cov ntawv thov tseem ceeb.
- Mus txog 600000kVA 7550kV
- Rated voltage: 12 - 550 kV
- Qhov siab tshaj plaws luv luv - lub sij hawm tiv taus tam sim no: 63 kA;
- Kev tiv thaiv qib: IP55
Custom Features
- Lub thawv qauv muaj xws li: prefabricated cabin qauv, txheem thawv qauv;
- Modular thawv qhov ntau thiab tsawg (10′–40′ ISO) rau ntau qhov chaw yuav tsum.
- Internal arc-proof tsim kev xaiv rau kev txhim kho kev nyab xeeb.
- Kev tiv thaiv xob laim, teeb pom kev zoo thaum muaj xwm ceev, tswb, thiab khoom siv kev nyab xeeb.
- Hnub ci PV step-up substations nrog integrated inverter / DC Cheebtsam.
- Cov kev xaiv rau daim phiaj automation, saib xyuas tej thaj chaw deb, thiab SCADA kev koom ua ke
- Cast resin, oil-filled, los yog air-insulated transformer xaiv raws li qhov project xav tau.

Tsheb -mounted mobile substation Transformer
Lub tsheb -mounted mobile transformer yog trailer- lossis chassis-mounted mobile substation uas sib txuas nrog lub siab-voltage transformer, MV/LV switchgear, tiv thaiv cov cuab yeej, thiab cov cuab yeej pabcuam rau hauv ib chav. Tsim los rau kev xa tawm sai thiab kev ua haujlwm sab nraum zoov, nws muab cov kev hloov pauv tau yooj yim, txhim khu kev qha hluav taws xob ib ntus kev daws teeb meem rau kev kub ntxhov, kev saib xyuas, thiab tej thaj chaw deb daim ntawv thov.
- Txog 240000kVA 330kV
- Rated voltage: 12 - 330 kV
- Qhov siab tshaj plaws luv luv - lub sij hawm tiv taus tam sim no: 63 kA;
- Kev soj ntsuam ntse & tswj - built-in SCADA / chaw taws teeb saib xyuas cov tshuab rau lub sijhawm tsis muaj sijhawm (voltage, tam sim no, kub) thiab chaw taws teeb tswj.
- Kev tiv thaiv ib puag ncig siab - IP55-rated enclosures, shockproof thiab corrosion-resistant xaiv rau hnyav ib puag ncig (high humidity, sandstorms, coastal area).

Kev Pabcuam Peb Muaj

Peb muab cov kev daws teeb meem hluav taws xob hloov hluav taws xob, los ntawm kev sab laj thiab khoom siv rau kev teeb tsa, commissioning, kev cob qhia, thiab tom qab - kev muag khoom. Peb pab pawg kws tshaj lij ua kom muaj kev nyab xeeb, txhim khu kev lag luam thiab kev txhawb nqa lub neej tag nrho rau kev ua haujlwm siab - kev faib hluav taws xob.
Vim Li Cas Xaiv Peb

Tsis paub meej Dab tsi yog txoj cai rau koj?
Peb cov engineers hluav taws xob tuaj yeem coj koj mus rau qhov kev daws teeb meem zoo tshaj plaws rau koj qhov kev xav tau.
Tej yaam num Reference
FAQ
Q: Cov txheej txheem thoob ntiaj teb twg koj cov transformers ua raws?
A: Peb lub tshuab hluav taws xob substation tau tsim, tsim, thiab sim ua raws li ANSI / IEEE C57, NEMA, DOE, IEC, CSA, thiab UL® cov qauv, raws li muaj. Txhua chav ua tau raws li lossis tshaj qhov kev cai tswjfwm thiab kev ua tau zoo rau kev siv hluav taws xob thoob ntiaj teb thiab kev siv hauv kev lag luam.
Q: Lub Hoobkas kev sim ua dab tsi ua ntej xa khoom?
A: Txhua lub tshuab hloov pauv tau dhau los ntawm kev kuaj xyuas lub Hoobkas raws li cov qauv siv tau. Cov kev sim ntsuas tuaj yeem hloov kho raws li qhov yuav tsum tau ua ntawm qhov project, thiab Factory Witness Testing (FAT) muaj nyob rau ntawm -qhov chaw lossis los ntawm kev sib tham video ruaj ntseg.
Q: Koj muab dab tsi tom qab- muag thiab kev txhawb nqa?
A: Peb muab cov ntaub ntawv ua tiav, cov ntaub ntawv kuaj xyuas lub Hoobkas, kev taw qhia kev teeb tsa, thiab kev txhawb nqa engineering txuas ntxiv kom ntseeg tau tias kev ua haujlwm zoo, kev ua haujlwm ruaj khov, thiab kev ua haujlwm ntev - lub sijhawm ua haujlwm thoob plaws lub tshuab hloov pauv lub neej.
Q: Koj puas muab mobile substation transformer daws teeb meem?
A: Yog. Peb muab cov kev daws teeb meem ntawm lub xov tooj ntawm tes thiab ib ntus hloov pauv uas tsim los rau cov lus teb thaum muaj xwm txheej ceev, kev tu ncua, thiab kev xa tawm sai, muab cov khoom siv hluav taws xob ruaj khov thaum tsis muaj chaw nyob ruaj khov.
Q: Lub tshuab hluav taws xob puas tuaj yeem hloov kho nrog cov thev naus laus zis tshiab?
A: Yog. Transformer substations tuaj yeem hloov kho dua tshiab nrog ntau dua - transformers ua tau zoo, kev soj ntsuam qib siab, thiab cov cuab yeej siv hluav taws xob ntse los txhim kho kev ua tau zoo, kev ntseeg siab, thiab kev hloov pauv rau cov kev xav tau ntawm kab sib chaws yav tom ntej.