SCOTECH muaj rectifier transformer mus txog 100 MVA 132 kV
Peb cov kev tsim hluav taws xob rectifier tuaj yeem tsim kho nrog cov phiaj xwm tshwj xeeb hluav taws xob thiab cua txias teeb tsa los txhawb kev xav tau kev lag luam thiab kev ua haujlwm tas mus li.
Raws li kev paub dhau los ntawm cov chaw tsim khoom siv hluav taws xob hloov pauv, SCOTECH muab cov kev daws teeb meem tshwj xeeb rau cov khoom siv hluav taws xob thiab cov khoom siv hluav taws xob.

Rectifier Transformer Project References
Peb cov phiaj xwm rectifier transformer nthuav dav ntau yam kev ntsuas hluav taws xob, qib voltage, thiab kev teeb tsa.
Thov tshawb xyuas qhov kev tshawb fawb txog qhov project hauv qab no kom pom seb peb tsim thiab xa cov rectifier li cas
transformers raws li kev ua haujlwm tshwj xeeb.
Rectifier Transformer Specifications
SCOTECH muab lub zog hluav taws xob hloov hluav taws xob hloov hluav taws xob nrog cov hluav taws xob hloov tau yooj yim, cua txias, thiab saib xyuas
configurations kom tau raws li cov qauv thoob ntiaj teb thiab cov kev xav tau ntawm qhov project.
|
|
Parameter |
Specification |
|
Cov qauv |
IEC, ANSI/IEEE, NEMA, CSA, thiab lwm yam. |
|
|
Rated zog |
Mus txog 100 MVA |
|
|
High Voltage |
Mus txog 132 kV |
|
|
Ntau zaus |
50 / 60 Hz |
|
|
Parallel Kev Ua Haujlwm |
Kev npaj muaj |
|
|
Radiators |
Galvanized los yog stainless hlau |
|
|
Kev txuag dej |
Nitrogen inert-gas system los yog conservator |
|
|
Kev ntsuas kub |
Thermal keyboards, thermocouples, lossis platinum RTDs |
Multi-Pulse & Phase-Shifting Rectifier Transformers
SCOTECH rectifier transformers yog tsim los txhawb ntau lub tshuab pulse rectifier los ntawm 6 mus rau 36 pulses.
Flexible winding thiab theem-shifting configurations muaj kom tau raws li qhov sib txawv
rectifier system yuav tsum tau thiab qhov project tej yam kev mob.
6–36 Pulse Rectifier Systems
SCOTECH tuaj yeem muab 6-pulse, 12-pulse, 18-pulse, 24-pulse, thiab 36-pulse rectifier transformer configurations rau txawv industrial rectification systems.
Flexible Phase-Shifting Configurations
Rau 12-pulse thiab siab dua-mem tes rectifier tshuab, SCOTECH muaj Delta / Wye thiab txuas ntxiv-delta sib txuas rau kev coj lossis lag luam theem hloov.
Auto-Wound Phase-Shifting Designs
Rau cov ntawv thov uas tsis xav tau kev hloov pauv hluav taws xob lossis hluav taws xob cais tawm, SCOTECH tuaj yeem muab kev hloov pauv hloov pauv hloov pauv hloov pauv hloov pauv, suav nrog cov qauv sib txawv thiab cov qauv sib txawv.
Customized Rectifier Configurations
Theem-shifting kev npaj, winding configurations, thiab lwm yam transformer tsis tau engineered raws li lub rectifier topology, hluav taws xob yuav tsum tau, thiab qhov project specifications.
|
Rectifier Transformer Structure |
||
|
|
Tus neeg saib xyuas Muab qhov chaw rau transformer roj expansion thiab contraction thaum lub sij hawm kub hloov. Oil Level Indicator Tso cai rau pom kev saib xyuas ntawm cov roj transformer qib. Gas Relay Muab kev tiv thaiv los ntawm kev txheeb xyuas cov roj tsub zuj zuj thiab cov roj txav tsis zoo nyob rau hauv lub transformer. Npauj Npaim Valve & Conservator Connection Pipe Siv rau roj ntws tswj thiab kev sib txuas ntawm lub ntsiab tank thiab conservator system. HV Terminal Muab cov kev sib txuas high-voltage rau transformer. LV Bushing Muab qhov kev sib txuas qis-voltage rau lub rectifier-sab circuit. Zero Phase Terminal Muab qhov teev zero-theem kev sib txuas raws li kev teeb tsa transformer. CT Terminal Box Muab kev sib txuas thiab kev nkag mus rau tam sim no transformer circuits. |
OLTC Enables on-load voltage tswj qhov twg yuav tsum tau los ntawm daim ntawv thov. PRV Muab lub siab nyem los tiv thaiv lub transformer tank tiv thaiv ntau sab hauv siab. PT100 rau Winding Kub Muab qhov ntsuas kub tsis tu ncua winding ntsuas rau kev ua haujlwm saib xyuas thiab kev tiv thaiv. Roj Hmab Valve Tso cai tswj kev ntws ntawm cov roj transformer thaum tu lossis kev pabcuam. Sealing Gasket Muab kev sib khi ntawm flange thiab cov ntsiab lus txuas los pab tiv thaiv cov roj to. Threaded Fasteners Cov txiv ntseej thiab bolts ruaj ntseg cov khoom siv kho tshuab thiab cov khoom sib txuas. |
|
Rectifier Transformer Drawing |
|
|
Cov kev kos duab rectifier transformer rau ib chav tsev 3635 kVA suav nrog cov qauv tsim thiab cov ntaub ntawv seem rau kev tshuaj xyuas cov khoom sib txuas, kev sib txuas, thiab kev teeb tsa ua ntej tsim khoom. Rau transformers nrog rau lwm yam peev xwm los yog ib qhov project configurations, thov hu rau SCOTECH rau tus coj technical drawings thiab dimensional ntaub ntawv.
|
|
Daim ntawv thov ntawm Rectifier Transformer
Electrochemical Electrolysis
Tsim los muab cov khoom muaj peev xwm AC zog rau cov tshuab rectifier siv hauv cov txheej txheem electrochemical thiab electrolysis.
Traction Power Systems
Siv nyob rau hauv traction substations thiab railway fais fab system yuav tsum tau txhim khu kev qha rectification thiab tas mus li ua hauj lwm.
DC Fais Fab Kis
Tsim nyog rau lub zog muaj peev xwm hloov pauv lub zog uas AC lub zog hloov mus rau DC rau kev sib kis thiab lwm yam kev siv.
Kev hloov pauv zaus
Siv nyob rau hauv tshwj xeeb fais fab kev hloov dua siab tshiab systems yuav tsum tau tswj voltage thiab zaus transformation.
Muaj Rectifier Power Supply
Tsim los rau cov txheej txheem kev lag luam uas yuav tsum tau ua kom tas mus li, muaj zog DC tam sim no los ntawm cov tshuab rectifier siab.
Metallurgy & Heavy Industry
Haum rau kev thov cov txheej txheem metallurgical thiab hnyav kev lag luam nrog cov khoom siv hluav taws xob siab thiab kev ua haujlwm tsis tu ncua.
Q: Dab tsi yog rectifier transformer?
A: Lub rectifier transformer yog ib qho transformer tshwj xeeb tsim los muab AC lub zog rau cov tshuab rectifier uas hloov AC rau DC. Tsis zoo li tus qauv fais fab transformers, nws yog engineered los lis nonlinear loads, siab tam sim no theem, harmonics, thiab tshwj xeeb hluav taws xob yuav tsum tau ntawm rectification systems.
Q: Yuav ua li cas lub rectifier transformer ua haujlwm?
A: Lub rectifier transformer converts lub zog AC nkag mus rau qhov voltage thiab tam sim no theem uas yuav tsum tau los ntawm lub rectifier. Lub downstream rectifier ces converts AC tso zis rau DC zog. Raws li kev tsim qauv, lub transformer kuj tseem tuaj yeem muab kev hloov pauv theem thiab kev sib cais hluav taws xob los txhawb kev kho ntau yam mem tes.
Q: Qhov txawv ntawm 12-pulse thiab 24-pulse rectifier transformer yog dab tsi?
A: Ib qho 12-pulse rectifier transformer feem ntau siv theem-hloov theem nrab windings los muab ob lub 6-pulse rectifier txuas hniav, thaum lub zog 24-pulse siv cov theem hloov pauv ntxiv kom ua tiav cov txheej txheem siab dua.
Q: SCOTECH puas tuaj yeem muab cov hluav taws xob siab thiab nruab nrab-voltage rectifier transformers?
A: Yog. SCOTECH muab cov khoom siv hluav taws xob hloov hluav taws xob rau cov chav kawm sib txawv thiab cov kev xav tau ntawm qhov project. Cov qauv tsim tuaj yeem tsim kho nrog cov ntsuas hluav taws xob siab txog li 132 kV, nrog rau qib voltage, rwb thaiv tsev, thiab winding configuration txiav txim siab raws li daim ntawv thov thiab cov qauv siv.
Q: Koj puas tuaj yeem tsim kev cai rectifier transformers?
A: Yog. Raws li ib tug rectifier transformer chaw tsim tshuaj paus thiab tsum, SCOTECH muab project-tsim qauv tsim raws li nyob rau hauv lub zog, voltage, mem tes configuration, theem hloov, impedance, cua txias, kev tiv thaiv, installation tej yam kev mob, thiab siv cov qauv. Engineering kos duab thiab cov ntaub ntawv xeem tuaj yeem muab rau kev tshuaj xyuas qhov project.
Q: Koj puas muab cov duab kos duab rectifier transformer thiab engineering drawings?
A: Yog. SCOTECH tuaj yeem muab cov duab kos duab sib txawv thiab cov duab kos duab engineering rau kev tshuaj xyuas, suav nrog kev teeb tsa dav dav thiab kos duab kos duab, kev sib txuas, thiab lwm yam ntaub ntawv tshwj xeeb raws li qhov xav tau.
Q: Kuv tuaj yeem yuav qhov kev cai rectifier transformer qhov twg?
A: SCOTECH yog lub chaw tsim khoom siv hluav taws xob hloov hluav taws xob thiab cov chaw muag khoom muab cov phiaj xwm tshwj xeeb tsim rau kev lag luam thiab kev siv hluav taws xob. Cov neeg siv khoom tuaj yeem xa lawv cov kev ntsuas hluav taws xob uas xav tau, qhov hluav taws xob, kev teeb tsa mem tes, qhov yuav tsum tau hloov mus rau theem, thiab kev teeb tsa rau kev ntsuas kev ntsuas thiab hais lus.
Q: Cov neeg muas zaub puas tuaj yeem pom FAT rau rectifier transformers?
A: Yog. Factory Acceptance Testing (FAT) tuaj yeem npaj nrog cov neeg siv khoom lossis cov neeg thib peb ua pov thawj raws li qhov yuav tsum tau ua. SCOTECH kuj tseem tuaj yeem muab cov ntawv xeem ua tiav raws li IEC cov cai, suav nrog FAT cov yeeb yaj kiab thiab cov ntaub ntawv xeem raws li kev thov.
Rectifier Transformer Manufacturing Txheej txheem
SCOTECH nruj me ntsis saib xyuas cov txheej txheem ntau lawm ntawm rectifier transformers thiab siv cov kev soj ntsuam zoo ntawm
txhua theem, nrog rau cov tub ntxhais thiab winding los ua ke, tank fabrication, tivthaiv installation, thiab kev xeem zaum kawg.

Laminated Core Manufacturing

Precision Winding

Tank Fabrication & Sealing

Kev Sib Tham zaum kawg
Rectifier Transformer Test & Kev Tswj Xyuas Zoo
SCOTECH rectifier transformers tau ua tiav txhua hnub, hom, thiab kev kuaj tshwj xeeb los xyuas cov hluav taws xob
kev ua tau zoo, rwb thaiv tsev ncaj ncees, txhua yam kev ntseeg siab, thiab kev nyab xeeb ua haujlwm ua ntej xa khoom.
Cov kev xeem niaj hnub
Cov kev ntsuam xyuas niaj hnub tau ua ntawm txhua lub tshuab hluav taws xob txhawm rau txheeb xyuas qhov tseem ceeb ntawm cov hluav taws xob thiab cov tshuab ua haujlwm ua ntej xa khoom.
• Kev ntsuas qhov ntsuas cua
• Voltage ratio thiab theem kev hloov chaw pov thawj
• Kev txheeb xyuas pawg vector
• Impedance voltage thiab load poob ntsuas
• Kev ntsuas luv-circuit impedance
• Tsis muaj-load poob thiab excitation tam sim no ntsuas
• Kev ntsuam xyuas dielectric niaj hnub
• Siv qhov ntsuas hluav taws xob
• Induced voltage test
• Kev kuaj roj to
Hom Kev Xeem
Hom kev ntsuas ntsuas thermal, dielectric, thiab acoustic kev ua tau zoo rau cov qauv tsim tshwj xeeb.
• Kev ntsuas kub nce
• Lightning impulse withstand test
• Hloov impulse tiv thaiv kev sim, yog qhov xav tau
• Kev ntsuas suab
• Tsis muaj-load tam sim no harmonic ntsuas
Kev kuaj tshwj xeeb
Kev ntsuam xyuas ntxiv tuaj yeem npaj rau kev ua haujlwm tshwj xeeb, kev qhia tshwj xeeb, lossis cov neeg siv khoom xav tau.
• Kev ntsuas qhov tso tawm ib nrab
• Zero-sequence impedance ntsuas
• Capacitance thiab tan δ ntsuas
• Kev tshuaj xyuas zaus teb (FRA)
• Winding kub-qhov kub ntsuas ntsuas
• Load rejection test
• Short-circuit withstand test
• Kev xeem seismic
• Dissolved gas analysis (DGA)






Ntau Daim Ntawv Thov Tshwj Xeeb Transformers los ntawm SCOTECH
Tshaj li rectifier transformers, SCOTECH manufactures ntau yam tshwj xeeb daim ntawv thov transformers engineered rau
xav tau kev lag luam thiab kev siv fais fab. Tshawb xyuas peb cov traction transformers, rauv transformers,
grounding transformers, thiab lwm yam kev daws teeb meem tshwj xeeb rau cov kev xav tau sib txawv.

Traction Transformers
Tsim los rau kev tsheb ciav hlau thiab kev thauj mus los fais fab, traction transformers muab kev ntseeg siab hloov hluav taws xob rau kev thov kev siv traction.

Rauv Transformers
Engineered rau high-tam sim no muaj txheej txheem xws li hluav taws xob arc rauv thiab lwm yam metallurgical daim ntaub ntawv yuav tsum tau tshwj xeeb transformer kev ua tau zoo.

Earthing Transformers
Muab qhov nruab nrab nruab nrab rau cov tshuab uas tsis muaj kev sib txuas nruab nrab uas tsim nyog thiab txhawb nqa hauv av thiab kev tiv thaiv cov cai.
Tau txais ib nqe lus ntawm Rectifier Transformer
Thov sau daim foos, thiab ib tus ntawm peb pab neeg yuav hu rau koj hauv 24 teev.

Jiangshan Scotech Hluav Taws Xob Co., Ltd yog ib qho ntawm cov ua lag luam thiab cov chaw muag khoom ntawm rectifier transformer hauv Suav teb. Peb sov siab txais tos koj mus yuav tus nqi hluav taws xob rectifier transformer rau muag ntawm no los ntawm peb lub hoobkas. Yog tias koj muaj lus nug txog kev hais lus lossis cov duab kos, thov koj xa email tuaj rau peb.













