SCOTECH muaj qhov chaw nres tsheb hloov pauv mus txog 10 MVA 34.5 kV
Kev vam meej Unit Substation Transformer Projects thoob ntiaj teb
SCOTECH thawj chav tsev substation transformers tau muab rau kev lag luam, kev lag luam, thiab kev siv hluav taws xob
thoob plaws ntiaj teb, ua tau raws li qhov xav tau ntawm lub zog muaj peev xwm, kev txhim kho yooj yim,
thiab kev ua haujlwm zoo.
|
|
Yam khoom |
Specification |
|
Hom Transformer |
Peb Theem Unit Substation Transformer |
|
|
Cov qauv siv tau |
IEC, ANSI/IEEE, NEMA, CSA, thiab lwm yam. |
|
|
Rated zog |
Mus txog 10 MVA |
|
|
Rated Zaus |
50 Hz / 60 Hz |
|
|
Rated rwb thaiv tsev Level |
Mus txog 161 kV |
|
|
Kub nce |
55℃/ 65℃/ 55 / 65℃/ 45 degree |
Unit Substation Transformer Accessories
|
|
Qeb |
Muaj Accessories |
|
Kev tiv thaiv Accessories |
Siab Relay, Bayonet Fuse, Tam sim no-Limiting Fuse, Tam sim no Transformer (CT), Neutral Grounding Resistor |
|
|
High & Low Voltage Connection Accessories |
High-voltage thiab low-voltage bushings, externally clamped bushings, low-voltage molded epoxy lossis porcelain bushings nrog NEMA spades |
|
|
Saib xyuas & Tswj Accessories |
Winding Temperature Indicator, Marshalling Box, On-Load Kais Changer (OLTC) |
|
|
Surge Protection Accessories |
Lub luj tshib Arrester, Nqus Fault Interrupter (VFI), IFD |
|
|
Txias System Accessories |
Kub-Dip Galvanized Radiators, kiv cua |
|
|
Daim Ntawv Thov Tshwj Xeeb Accessories |
Customized daws teeb meem rau kev sib haum xeeb loading thiab teev K-factor yuav tsum tau |
Vim li cas thiaj xaiv Peb Chav Substation Transformer
PCB-Dawb Roj rau
Txhim khu kev ruaj ntseg
Peb chav tsev substation transformers siv PCB-dawb insulating roj los txo qhov kev pheej hmoo ntawm ib puag ncig. Xaiv tauChav Kawm I Division 2configurations muaj nyob rau hauv qhov chaw muaj kev phom sij.
Txhim khu kev ua tau zoo
nyob rau hauv cov xwm txheej heev
Tsim rau offshore, marine, high-altitude, thiab industrial ib puag ncig, nrog rau kev ua haujlwm muaj peev xwm mus txog14,850 ft FASLthiab kho cov kev daws teeb meem rau cov kev xav tau tshwj xeeb.
High-Efficiency
Transformer Tsim
Ua raws li cov qauv kev ua haujlwm siab, suav nrog DOE cov cai. Kev xaiv amorphous core thev naus laus zis txo qhov tsis muaj kev thauj khoom los ntawm dhau70%, txhim kho kev txuag hluav taws xob thiab kev ua haujlwm ntawm lub neej.
Smart Cooling System rau
Optimized ua haujlwm
Cov cuab yeej ua kom txias txias tau hloov kho kev ua haujlwm raws li kev thauj khoom, txo kev siv hluav taws xob thiab txhim kho kev ua haujlwm ntawm transformer.
Kev tsim kho muaj zog rau
Txhim khu Durability
Heavy-duty transformer tanks tiv taus siab mus txog15 psig, thaum epoxy-resin insulated windings txhim kho luv-circuit tsis kam thiab ua haujlwm kev ntseeg tau.
Flexible Customization rau
Qhov xav tau ntawm qhov project
Muaj nrog customized impedance, low-suab designs (down to20 dBA), marine-qib coatings, thiab txhim kho seismic tiv thaiv kom tau raws li ntau yam kev thov.
Chav tsev Substation Transformer Applications

• Kev tsim cov nroj tsuag
• Cov chaw ua haujlwm
• Cov chaw zov me nyuam
• Cov tsev lag luam

• Solar farms
• Cua fais fab nroj tsuag
• Roj teeb lub zog cia tshuab (BESS)

• Cov chaw mining
• Mineral processing nroj tsuag
• Cov chaw ua haujlwm nyob deb

• Kev faib tawm substations
• Kev tsim kho vaj tse
• Public power systems
Q: Dab tsi yog qhov txawv ntawm ib chav tsev substation thiab ib txwm transformer?
A: Ib qho kev hloov pauv tsis tu ncua tsuas yog ua qhov hloov pauv hloov hluav taws xob, thaum lub tshuab hluav taws xob sib txuas ua ke nrog lub tshuab hluav taws xob nruab nrab thiab cov khoom siv hluav taws xob tsawg, cov cuab yeej tiv thaiv, thiab cov khoom siv. Qhov kev tsim qauv sib xyaw no yooj yim rau kev teeb tsa thiab txhim kho kev ntseeg tau.
Q: Dab tsi yog qhov nruab nrab voltage chav tsev substation transformer?
A: Ib qho nruab nrab voltage unit substation transformer yog tsim los kom tau txais hluav taws xob nruab nrab hluav taws xob thiab xa mus rau cov tshuab hluav taws xob tsawg. Cov chav kawm voltage muaj xws li 4.16 kV, 13.8 kV, 25 kV, thiab 34.5 kV nyob ntawm seb qhov project yuav tsum tau ua.
Q: Chav tsev substation transformers puas tuaj yeem tsim kho rau cov haujlwm tshwj xeeb?
A: Yog. Kev cai tsim chav tsev substation transformers tuaj yeem tsim raws li qhov yuav tsum tau ua, suav nrog kev ntsuas hluav taws xob, lub zog muaj peev xwm, impedance, tsim thaiv, tiv thaiv cov cuab yeej, cua txias, thiab tshwj xeeb ib puag ncig.
Q: Kuv yuav xaiv qhov chaw substation transformer zoo li cas rau kuv qhov project?
A: Kev xaiv nyob ntawm ntau yam, suav nrog lub peev xwm xav tau, theem pib thiab theem nrab voltage, load yam ntxwv, ib puag ncig kev teeb tsa, kev tiv thaiv kev tiv thaiv, thiab cov qauv hluav taws xob siv tau.
Q: Dab tsi yog qhov txawv ntawm qhov chaw nruab nrab ntawm qhov chaw nruab nrab thiab qhov chaw nruab nrab ntawm qhov chaw nres tsheb?
A: Ib qho chaw tseem ceeb ntawm lub chaw nres tsheb feem ntau tau txais lub zog nruab nrab siab dua thiab ua rau nws mus rau theem kev faib hluav taws xob. Ib chav tsev thib ob substation txuas ntxiv faib hluav taws xob ntawm cov hluav taws xob qis rau cov khoom siv kawg thiab cov chaw siv.
Manufacturing Peev xwm rau Unit Substation Transformers
Raws li ib qho kev paub txog chav tsev substation transformer chaw tsim tshuaj paus, SCOTECH muab tag nrho cov tsim thiab engineering peev xwm rau customized unit substation transformer daws teeb meem. Nrog cov chaw tsim khoom siab heev, pab pawg kws tshaj lij engineering, thiab kev tswj hwm nruj, peb txhawb cov neeg siv khoom thoob ntiaj teb nrog txhim khu kev qha nruab nrab voltage faib transformers.
Advanced Production
Cov chaw
Peb cov chaw tsim khoom tau nruab rau kev ua tiav transformer ntau lawm, sib dhos, thiab kev sim, suav nrog:
• Transformer core processing
• Coil winding ntau lawm
• Transformer tank fabrication
• MV/LV system integration
• Kev ntsuas hluav taws xob ua haujlwm
Factory Assembly &
Kev sim
Txhua chav tsev substation transformer yog sib sau ua ke thiab tshuaj xyuas ua ntej xa khoom.
Kev tshuaj xyuas zoo suav nrog:
• Kev ntsuas kev ua haujlwm ntawm Transformer
• Kev tshuaj xyuas kev sib txuas MV/LV
• Kev pov thawj kev tiv thaiv
• Factory lees txais (FAT)
Engineering & Customization
Muaj peev xwm
Peb pab neeg ua haujlwm engineering ua haujlwm nrog cov neeg siv khoom los txhim kho chav tsev substation transformers raws li:
• Cov kev xav tau ntawm chav kawm voltage
• Lub zog muaj peev xwm
• Kev teeb tsa kev teeb tsa
• Kev tiv thaiv kev teeb tsa
• Cov kev cai ib puag ncig
• Cov qauv siv tau
Peb Lub Tsev Substation Transformer Factory
-
Txheej txheem ntau lawm
-
Unit Substation Transformers Test
Unit Substation Transformer Selection Guide
Xaiv txoj cai chav tsev substation transformer yuav tsum tau ua tib zoo xav txog lub hwj chim,
voltage theem, installation ib puag ncig, thiab kev tiv thaiv yuav tsum tau.
Txiav txim siab muaj peev xwm
Lub peev xwm transformer yuav tsum raug xaiv raws li:
• Txuas load
• Cov kev xav tau nthuav dav yav tom ntej
• Load yam ntxwv
• Kev ua haujlwm tsis tu ncua
01
Paub meej tias qhov yuav tsum tau muaj voltage
Cov chav kawm nruab nrab voltage muaj xws li:
• 4.16 kV
• 13.8 kV
• 25 kV
• 34.5 kV
Tsawg voltage outputs:
• 480 V
• 600 V
• Customized voltage theem
02
Xav txog Installation Ib puag ncig
Yam muaj xws li:
• Kev teeb tsa sab hauv lossis sab nraum zoov
• Ambient kub
• Qhov siab
• Cov av noo
• Corrosive ib puag ncig
03
Xaiv Kev Tiv Thaiv Configuration
Cov kev xaiv muaj xws li:
• Fuses
• Circuit Court breakers
• Cov tub ceev xwm ceev ceev
• Saib xyuas cov khoom siv
04
Tau txais Daim Ntawv Tso Cai ntawm Ib Chav Tsev Substation Transformer
Thov sau daim foos, thiab ib tus ntawm peb pab neeg yuav hu rau koj hauv 24 teev.

Jiangshan Scotech Electrical Co., Ltd yog ib qho ntawm cov tuam txhab ua lag luam thiab cov chaw muag khoom ntawm chav tsev substation transformer hauv Suav teb. Peb sov siab txais tos koj mus yuav cov nqi hluav taws xob hluav taws xob hluav taws xob hluav taws xob rau muag ntawm no los ntawm peb lub hoobkas. Yog tias koj muaj lus nug txog kev hais lus lossis cov duab kos, thov koj xa email tuaj rau peb.