Peb Theem Ncej Mounted Transformer

Scotech muaj peb theem PEXS Mounted Transformer txog 1000 KVA 34.5 kV

Kev Muag Khoom
  • Kev qhia txog ib yam
  • Ntawv
Nrhiav tau
Peb Theem Ncej Mounted Transformer
Txog li 1000 kva 34.5 kV
Lub peb-theem ncej-mounted transformers tsim tawm los ntawm Scotech tau tsim nrog cov khoom siv ruaj khov thiab huab cua-resistant cov ntaub ntawv los xyuas kom meej lub sijhawm ntev thiab ua tau zoo hauv ntau yam kev mob. Nruab nrog cov thev naus laus zis thev naus laus zis, lub transformer muaj kev tiv thaiv hluav taws xob thiab lub zog loj. Nws yog qhov haum rau cov pob hluav taws nyob deb nroog, cov tsev nyob deb, teeb pom kev zoo, thiab muaj peev xwm siv tau rau lub zog-txuag kev hloov pauv ntawm cov tsheb ciav hlau thiab cov nroog fais fab loj.
Rub daim ntawv qhia
productcate-1-1
Cov txiaj ntsig
  • Muaj zog
    kev faib
  • Dawb
    kho
  • Muaj peev xwm
    daim ntawv thov
  • Kev Ntsuas Lub Tsheb
    kev faib
Nta
productcate-1-1

Kev qhia tshwj xeeb

  • Cov qauv tau tsim raws li IEC, Ansi / Ieee, NEMA, CSA, thiab lwm yam
  • Rated zog los ntawm10KVA txog 1000 KVA
  • Rated rwb thaiv tsev qib mus txog 34,5 kV
  • Cov zaus ntsuas 50 lossis 60 Hz
  • Thermal Rwb Thaiv Tsev KawmF
  • E4, C4, F1, F1 nyuam qhuav muaj ntawv pov thawj tshiab rau IEC {3}}: 2018
  • Kuj mus rau cov huab cua siab>95%
  • Ib txwm txias (a) lossis cua yuam (af) ntawm kev thov
  • Nyob sab hauv tsev lossis sab nraum zoov ntawm kev thov (nrog rau ntawm IP44)
  • On-load Kov Changer (OLTC) raws li kev thov tshwj xeeb
  • Lub impedance ntau yog0.5% ~ 10%
  • Cov pab pawg ntawm kev koom nrog yog Dyn11 lossis yyn 0
Phau ntawv

 

 

 

 

75 kVA 3 Phase Ncej Transformer-13.8/0.22 kV|Guyane xyoo 2024
75 kVA 3 Phase Ncej Transformer-13.8/0.22 kV|Guyane xyoo 2024
Lub teb chaws: Guyana 2024
Peev xwm: 50kVA
Lub Zog: 13.8 / 0.22kV
Feature: nrog OCTC
25 kVA Ncej Mounted Peb Theem Transformer-5.5/0.4 kV|Fabkis 2024
25 kVA Ncej Mounted Peb Theem Transformer-5.5/0.4 kV|Fabkis 2024
Lub teb chaws: Fabkis 2024
Peev xwm: 25kVA
Qhov hluav taws xob: 5.5 / 0.4kV
Feature: nrog roj qib ntsuas
112.5 KVA Ncej Mounted 3 Theem Transformers-13.8/0.208 KV|Canada 2025
112.5 KVA Ncej Mounted 3 Theem Transformers-13.8/0.208 KV|Canada 2025
Lub teb chaws: Canada 2025
Muaj peev xwm: 112.5 kVA
Qhov hluav taws xob: 13.8D-0.12 / 0.208kV
Feature: nrog roj qib ntsuas
Daim Ntawv Qhia Cov Khoom Zoo Zoo

Scotech peb theem PEXS ncej sib pauv xa cov kev ua haujlwm siab thiab ua haujlwm tau zoo, muab kev nyab xeeb ntawm kev nyab xeeb thiab kev ntseeg tau ...