Cam khwb cia ua kom qhuav Transformer

Scoteech muaj cam khwb cia Resin qhuav hom hloov pauv mus txog 20 MVA 35 kV

Kev Muag Khoom
  • Kev qhia txog ib yam
  • Ntawv
Nrhiav tau
Cam khwb cia qhuav Toucharrantformer
Txog li 20 MVA 35 kV
Scotech Cam khwb cia coil Qhuav hloov cov hloov pauv kev nyab xeeb thiab kev ntseeg tau, muab theem siab, muab cov ntaub ntawv muaj kev nyab xeeb, muab cov ntaub ntawv muaj kev nyab xeeb, muab cov chaw muaj kev nyab xeeb, muab cov chaw zov me nyuam siab, cov chaw zov me nyuam, thiab tshav dav hlau.
Rub daim ntawv qhia
productcate-1-1
Cov txiaj ntsig
  • Yooj yim
    Kev muab cia
  • Dawb
    Kho
  • Siab
    Ua tau zoo
  • Tus kheej
    Chaw kho mov
Nta
productcate-1-1

Kev qhia tshwj xeeb

Cov qauv tau tsim los ua IEC, Ansi / Ieee, NEMA, CSA, BS, thiab lwm yam
• Rated Hwj Chim Los Ntawm 50 KVA txog 20 MVA
• Rated High Voltage Txog 35 kV
• Kev ntaus nqi ntau 50 lossis 60 HZ
• Raws li kev sib txuas hnub qub
• Txuj Ci Tapping Hem: ± 2.5%, ± 5%
• MV Windings encapsulated nyob rau hauv cam khwb cia resin
• a, e, b, f, h rwb thaiv tsev yog txhua yam muaj.
• Muab: IP 2x, IP 3x, IP 4X
• ib txwm o (k) nan, o (k) naf ntawm kev thov
• Kev tiv thaiv thermal:
Ib qhov system txias: 6 PTC sensors (lossis 3 pt100) + thermal relay
AF Khaub Ncaws System: 6 PT100 Sensors (lossis 9 PTC) + Thermal Relay
• Lub log, hloov pauv tam sim no, OLTC, MARSALLING BOX thiab lwm yam khoom siv muaj
Phau ntawv

 

 

 

 

650 kva cam khwb cia coil transformers-11 / 0.34 kv|Tebchaws Asmeskas emirates 2025
650 kva cam khwb cia coil transformers-11 / 0.34 kv|Tebchaws Asmeskas emirate...
Tus me nyuam Lub teb chaws: United Arab emirates 2025
Peev Xwm: 650kva
Voltage: 11000 / 340V
Nta: Nrog Kob IP20
30 KVA Hom Qhuav Transformer-11 / 0.22 kv|Tebchaws Asmeskas emirates 2025
30 KVA Hom Qhuav Transformer-11 / 0.22 kv|Tebchaws Asmeskas emirates 2025
Tus me nyuam Lub teb chaws: United Arab emirates 2025
Peev Xwm: 30Kva
Voltage: 11 / 0.22kV
Nta: Kas IP20
3 MVA Qhuav Hom Transformers-13.8/0.48 kV|Jamaica 2025
3 MVA Qhuav Hom Transformers-13.8/0.48 kV|Jamaica 2025
Lub teb chaws: Jamaica 2025
Muaj peev xwm: 2400/3000kVA
Qhov hluav taws xob: 13.8 / 0.48kV
Feature: nrog cua txias
2500 kVA Qhuav Transformer-10/0.4 kV|Georgia 2025
2500 kVA Qhuav Transformer-10/0.4 kV|Georgia 2025
Lub teb chaws: Georgia 2024
Peev xwm: 2500kVA
Lub hwj chim: 10/0.4kV
Feature: nrog kub tswj
2100 kVA Qhuav Hom Distribution Transformer-13.8/0.46 kV|South Africa 2024
2100 kVA Qhuav Hom Distribution Transformer-13.8/0.46 kV|South Africa 2024
Lub Tebchaws: South Africa 2024
Peev xwm: 2100kVA
Qhov hluav taws xob: 13.8 / 0.46 kVA
Feature: Nrog CT (5000/1)
1500 KVA Nruab Nrab Voltage Qhuav Hom Transformers-15/0.55 KV|South Africa 2025
1500 KVA Nruab Nrab Voltage Qhuav Hom Transformers-15/0.55 KV|South Africa 2025
Lub teb chaws: South Africa 2025
Muaj peev xwm: 1500kVA
Lub hwj chim: 15/0.55 kV
Feature: nrog cov kiv cua txias
1.25 MVA Cast Resin Hom Transformer-0.415/3.3*6.6 kV|Malaysia 2025
1.25 MVA Cast Resin Hom Transformer-0.415/3.3*6.6 kV|Malaysia 2025
Lub teb chaws: Malaysia 2025
Muaj peev xwm: 1000/1250 kVA
Lub hwj chim: 0.415-3.3 / 6.6 kV +2 * 10% kV
Feature: nrog enclosure thiab log
800 KVA Tsawg Voltage Qhuav Hom Transformer-6.6/0.55 KV|South Africa 2025
800 KVA Tsawg Voltage Qhuav Hom Transformer-6.6/0.55 KV|South Africa 2025
Lub teb chaws: South Africa 2025
Muaj peev xwm: 800 kVA
Qhov hluav taws xob: 6.6 / 0.55 kV
Feature: 100K winding kub nce
630 kVA Cast Resin Dry Type Transformer-66.6/0.55 kV|South Africa 2024
630 kVA Cast Resin Dry Type Transformer-66.6/0.55 kV|South Africa 2024
Lub teb chaws: South Africa 2024
Peev xwm: 630kVA
Qhov hluav taws xob: 66.6 / 0.55kV
Feature: nrog kiv cua
630 kVA Cast Coil Transformer-6.6/0.55 kV|South Africa 2025
630 kVA Cast Coil Transformer-6.6/0.55 kV|South Africa 2025
Lub teb chaws: South Africa 2025
Peev xwm: 630 kVA
Qhov hluav taws xob: 6.6 / 0.55 kV
Feature: nrog kub maub los thiab kiv cua
630 kVA 3 Theem Qhuav Hom Transformer-6.6/0.55 kV|South Africa 2025
630 kVA 3 Theem Qhuav Hom Transformer-6.6/0.55 kV|South Africa 2025
Lub teb chaws: South Africa 2024
Peev xwm: 630kVA
Lub Zog: 6.6 / 0.55kV
Feature: rwb thaiv tsev theem H
630 kVA Peb Theem Qhuav Hom Transformer-10/0.4 kV|Georgia 2025
630 kVA Peb Theem Qhuav Hom Transformer-10/0.4 kV|Georgia 2025
Lub teb chaws: Georgia 2024
Peev xwm: 630 kVA
Lub hwj chim: 10/0.4kV
Feature: nrog kub tswj
Daim Ntawv Qhia Cov Khoom Zoo Zoo

Peb nyob zoo {-}}}}} paub yog ib qho ntawm cov ua lead cam coil qhuav hom transformer cov chaw tsim khoom thiab cov muag khoom hauv Suav teb. Yog tias koj yuav mus yuav tus nqi - Qhov xim kas nruab co hlua, txais tos kom tau txais cov ntaub ntawv ntxiv los ntawm peb lub hoobkas.