1000 kVA Vpi Transformer-11/0.55 kV|South Africa 2024

1000 kVA Vpi Transformer-11/0.55 kV|South Africa 2024

Lub teb chaws: South Africa 2024
Peev xwm: 1000kVA
Lub hwj chim: 11/0.55kV
Feature: nrog kub tswj
Xa kev nug

 

 

vpi transformer

VPI Qhuav-Hom Transformer: Qhov kev xaiv tshiab rau eco-tus phooj ywg, muaj txiaj ntsig, thiab muaj kev nyab xeeb xa hluav taws xob!

 

01 General

1.1 Project Background

Qhov no 1000kVAvpi transformer uayog xa tawm mus rau South Africa thaum Lub Xya Hli, 2024. Pawg vector ntawm no transformer yog Dyn11. Dyn11 kev twb kev txuas txoj kev, high voltage zoo, nruab nrab taw tes tsis drift. Thawj qhov hluav taws xob yog 11 kV, qhov nruab nrab qhov hluav taws xob yog 0.55 kV, lub tshuab hloov pauv yog nruab nrog tsis muaj qhov hloov pauv hloov pauv, qhov tapping ntau yog ± 2 * 2.5% ntawm thawj sab, qhov txias yog ONAN / ONAF.

Covqhuav hom transformerNws muaj cov yam ntxwv ntawm cov nplaim hluav taws kub retardant qauv, tsis tshua muaj suab nrov, lub teeb yuag, me me hneev taw, poob qis, kev nyab xeeb, ruaj khov, siab kub tsis kam thiab muaj zog tshaj qhov muaj peev xwm. Nrog nws cov kev ua tau zoo heev tau txais tos los ntawm kev lag luam hauv tsev, cov khoom lag luam raug xa tawm mus rau European Union, North America, Middle East thiab lwm thaj chaw kev lag luam thoob ntiaj teb.

 

1.2 Technical Specification

1000 kVA vpi transformer specification thiab cov ntaub ntawv

Xa rau
South Africa
Xyoo
2024
Qauv
1000kVA-11/0.55kV
Hom
Qhib winding qhuav hom transformer
Txuj
IEC60076
Rated zog
1000kVA ua
Ntau zaus
50 HZ
Theem
3
Hom cua txias
UA/AF
Thawj Voltage
11kv ua
Secondary Voltage
0,55kv :ua
Cov khoom siv winding
Aluminium
Impedance
6%
Coj mus rhaub Changer
NLTC
Tapping Range
± 2 * 2.5% @ thawj sab
Tsis Load Loss
1.8 KW TSI
Ntawm Load Loss
9.1kW ua
Khoom siv
Standard Configuration
Rwb thaiv tsev theem
H
Basic impulse teeb pom kev zoo tiv taus voltage- sab xub ntiag (BIL)
75kv ua
Lub zog zaus tiv taus qhov voltage- sab xub ntiag
35kv ua
Basic impulse teeb pom kev zoo tiv taus voltage-secondary side (BIL)
/
Fais fab zaus tiv taus qhov voltage-secondary side
3kv ua
Winding kub nce @ ntsuas kev pabcuam
100K

 

1.3 Cov duab kos

1000 kVA vpi transformer daim duab kos duab thiab loj.

vpi transformer diagram

 

02 Kev tsim khoom

2.1 Core

Cov tub ntxhais hlau txais kev pom zoo permeability magnetic grain orientation txias dov silicon steel ntawv (CRGO), tag nrho oblique tsis- qhov khi, ua -hauv rub phaj qauv, tsim cov duab kos duab, txiav txim siab cov yam ntxwv ntawm cov ntawv sib nqus siv thiab ntau cov ntsiab lus, suav nrog kev tswj kev vibration, qaij txoj hauj lwm thiab lwm yam kev xav tau thiab lwm yam kev hloov kho kom zoo nkauj, yog li kev hloov pauv tsis zoo, thiab lwm yam. tsis muaj-load tam sim no, me tsis muaj-load poob. Tsawg suab nrov.

vpi transformer CRGO core

 

2.2 Cua txias

vpi transformer electrical coils

Lub high voltage coil txais cov qauv nruam winding, coil tshav kub dissipation yog zoo, yog li ntawd lub overload muaj peev xwm ntawm lub transformer yog muaj zog, thiab lub siab surge voltage yog kev ntseeg siab. Qhov qis-voltage kauj yog ntawv ci, thiab qhov kub ntawm qhov sib faib hauv qhov cua yog qhov sib npaug, uas txhim kho qhov ruaj khov ntawm lub kauj thiab txhim kho qhov luv - Circuit Court tsis kam. Lub kauj siv lub tshuab nqus tsev siab impregnated H-chav hluav taws xob retardant xim, thiab kho tau ntawm qhov kub thiab txias, thiab qhov saum npoo tuaj yeem ua plua plav, noo noo- pov thawj thiab stain- pov thawj.

 

2.3 Lub Rooj Sib Tham Kawg

Winding qhov chaw: thawj winding thiab theem nrab winding yog ntsia rau ntawm cov tub ntxhais hlau raws li tus qauv tsim.

Winding kev twb kev txuas: Txuas lub winding davhlau ya nyob twg raws li cov hluav taws xob kos duab los xyuas kom meej qhov kev twb kev txuas yog ruaj khov.

Cov ntaub ntawv rwb thaiv tsev: Muab cov ntaub ntawv rwb thaiv tsev (xws li cov ntawv insulating thiab cov roj insulating) raws li cov qauv tsim kom ntseeg tau tias kev ruaj ntseg ntawm cov rwb thaiv tsev. Rwb thaiv tsev kuaj: ib qho kev ntsuas rwb thaiv tsev yog ua los xyuas kom meej tias cov rwb thaiv tsev ua tau raws li cov kev qhia tshwj xeeb.

Cov kiv cua lossis cov cua txias: Nruab lub tshuab hloov pauv cov kiv cua lossis cov cua txias kom ntseeg tau tias cov cua txias tuaj yeem ua kom cov cua sov tau zoo.

Plhaub fixation: Nruab lub plhaub los yog tus neeg saib xyuas ntawm lub transformer nyob rau hauv qhov chaw kom paub meej tias lub plhaub yog kaw nrog lub ntsiab lub cev ntawm lub transformer.

Cable kev twb kev txuas: Txuas lub siab thiab tsis tshua muaj voltage cables ntawm lub transformer kom paub meej tias cov hluav taws xob kev twb kev txuas yog muaj zog thiab ua tau raws li cov qauv kev ruaj ntseg.

Grounding: Ua kev kho av kom ntseeg tau tias cov av ntawm lub tshuab hloov pauv tau zoo.

vpi transformer final assembly

 

 

03 Kev Xeem

Tsis muaj.

Cov khoom kuaj

Chav tsev

Kev txais txiaj ntsig

Ntsuas Tus Nqi

Xaus

1

Kev ntsuas ntawm winding kuj

/

Maximum kuj unbalance tus nqi

Kab tsis kam: Tsawg dua lossis sib npaug li 2%

HV (kab)

LV (kab)

Hla

0.20%

0.98%

2

Kev ntsuas qhov sib piv ntawm qhov voltage thiab xyuas cov theem hloov chaw

/

Kev kam rau siab ntawm qhov sib piv ntawm tus thawj tapping: ± 1/10

Cov cim kev sib txuas: Dyn11

-0.03% ~ 0.09%

Dyn 11

Hla

3

Kev ntsuas luv- Circuit Court Impedance thiab Load Poob

/

kW

kW

t: 120 degree

Z%: ntsuas tus nqi

Pk: ntsuas tus nqi

Pt: ntsuas tus nqi

6.24%

6.28

7.909

Hla

4

Kev ntsuas tsis muaj -load poob thiab tam sim no ntawm 90% thiab 110% ntawm qhov ntsuas hluav taws xob

/

kW

I0 :  muab ntsuas tus nqi

P0: muab ntsuas tus nqi

90% ua

110% Yog

Hla

0.378%

0.462%

1.3734

1.6786

5

Applied Voltage Test

/

HV: 35kV 60s

lwv: 3kv60

Tsis muaj kev sib tsoo ntawm qhov ntsuas hluav taws xob tshwm sim

Hla

6

Induced Voltage Withstand Test

/

Kev siv hluav taws xob (kV): 2 Ur

Induced voltage (kV): 1.1

Duration(s): 40

Zaus (HZ): 150

Tsis muaj kev sib tsoo ntawm qhov ntsuas hluav taws xob tshwm sim

Hla

7

Kev kuaj qhov tso tawm ib nrab

pC ua

Qhov siab tshaj plaws ntawm kev tso tawm ib nrab yuav tsum yog 10 pC

<10

Hla

 

vpi transformer testing
vpi transformer fat

 

 

04 Packing thiab Shipping

1000kva vpi transformer packing

vpi transformer shipping

 

05 Site thiab Summary

Ua tsaug rau koj txaus siab rau vpi transformer! Peb cov khoom tau txais kev lees paub dav dav rau lawv cov kev ua tau zoo, kev ntseeg siab zoo, thiab ntau yam qauv tsim raws li kev xav tau sib txawv. Txawm hais tias yog rau kev lag luam, kev lag luam, lossis kev siv tshwj xeeb, VPI qhuav-hom transformers xa cov txiaj ntsig zoo, nyab xeeb, thiab ntev - kev daws teeb meem ntev. Peb cia siab tias yuav dhau los ua koj tus khub uas ntseeg siab hauv kev tsav tsheb cov kev daws teeb meem ntse thiab lub neej yav tom ntej. Yog xav paub ntxiv lossis cov kev pabcuam customized, thov hu rau peb txhua lub sijhawm!

vpi transformer manufacturers

 

Cim npe nrov: vpi transformer, chaw tsim tshuaj paus, tsum, nqe, nqi

Xa kev nug