50 KVA Hluav Taws Xob Transformer Ntawm Ncej-2.4*7.2/0.12*0.24 KV|Canada 2025
Peev xwm: 50kVA
Qhov hluav taws xob: 2.4 * 7.2-0.12 / 0.24kV
Feature: Dual{0}}voltage transformer nrog IFD
Jiangshan Scotech Electrical Co., Ltd yog ib qho ntawm feem txhim khu kev qha manufacturers thiab lwm tus neeg ntawm 50 kva hluav taws xob transformer rau ncej-2.4*7.2/0.12*0.24 kv|canada 2025 hauv Suav teb. Thov koj xav tias dawb mus yuav cov khoom lag luam raug nqi muag ntawm no thiab tau txais daim duab kos los ntawm peb lub hoobkas. Tiv tauj peb kom paub meej ntxiv.

50 kVA hluav taws xob transformer ntawm ncej - dual-voltage nrog IFD rau kev txhim khu kev qha Canadian nyob deb nroog
01 General
1.1 Cov Ntsiab Lus Mob Rau Cov Neeg Siv Khoom
Canadian tis network feem ntau xav tau 120/240 V cov khoom siv thib ob, thaum ua haujlwm hla ntau lub hauv paus hluav taws xob, tshwj xeeb tshaj yog nyob deb nroog thiab tsawg- thaj chaw ntom ntom. Cov khoom siv hluav taws xob yog li ntawd nyob rau hauv lub siab los xa cov transformers uas tuaj yeem hloov mus rau qhov sib txawv feeder configuration yam tsis muaj qhov nyuaj ntxiv.
Cov teeb meem tseem ceeb suav nrog:
• Kev txwv tsis pub nkag mus rau thaj chaw nyob deb nroog, yuav tsum muaj kev ntseeg siab thiab kev saib xyuas tsawg
• Ua kom pom tseeb ntawm kev ua haujlwm nyab xeeb, tshwj xeeb tshaj yog kev tiv thaiv sab hauv
• Cov khoom muag thiab kev thauj khoom siab los ntawm ib qho -voltage transformer designs
Cov kev daws teeb meem feem ntau tsis muaj qhov hloov pauv uas xav tau los daws cov teeb meem no, ua rau ob lub-voltage ncej-mounted transformer nrog kev tiv thaiv IFD kev ua haujlwm zoo dua thiab muaj kev nyab xeeb dua.
1.2 Cov ntawv thov ib txwm rau Canadian Nyiaj Siv Ua Haujlwm Sib Txuas Sib Txuas
Qhov no 50kVA Ncej-mounted hluav taws xob transformer yog tsim los rau kev faib khoom siv hluav taws xob uas muab 120/240 V kev pabcuam hauv Canada. Nws configuration ua rau nws tshwj xeeb tshaj yog haum rau:
• Cov kab nyiaj siv ua haujlwm nyob hauv nroog
• Cov zej zog nyob thiab cov khoom lag luam teeb
• Kev faib khoom siv hluav taws xob uas yuav tsum tau ua raws CSA C2.2-06
Lub dual -voltage thawj tsim tso cai rau kev xa tawm thoob plaws hauv lub network sib txawv yam tsis muaj kev hloov pauv ntawm cov qauv, txhim kho qhov yooj yim thaum tswj kev ua haujlwm zoo ib yam hauv kev ua haujlwm sab nraum zoov.
1.3 Technical Specification
50kVA hluav taws xob transformer ntawm ncej specification thiab cov ntaub ntawv ntawv
|
Xa rau
Canada
|
|
Xyoo
2025
|
|
Hom
Ncej mounted transformer
|
|
Txuj
CSA C2.2-06
|
|
Rated zog
50 KVA ua
|
|
Ntau zaus
60 tzs
|
|
Theem
Ib leeg
|
|
Hom cua txias
ONAN
|
|
Ua kua insulating
Mineral Roj
|
|
Thawj Voltage
2.4 * 7.2-0.12 / 0.24kV 2.4 hli
|
|
Secondary Voltage
120 / 240 V
|
|
Polarity
Ntxiv
|
|
Vector Group
Ib 6
|
|
Cov khoom siv winding
Aluminium
|
|
Impedance
2.85%(±10%)
|
|
Kev ua tau zoo
Ntau dua lossis sib npaug li 98.83%
|
|
Coj mus rhaub Changer
NLTC
|
|
Tsis Load Loss
139 W
|
|
Ntawm Load Loss
693 W
|
|
Khoom siv
Dual{0}}voltage transformer nrog IFD
|
1.4 Cov khoom zoo
Cov ncej no-mounted hluav taws xob transformer muab kev sib xyaw ua ke ntawm kev yoog raws, kev nyab xeeb, thiab kev siv hluav taws xob los ntawm cov txiaj ntsig hauv qab no:
• Dual -voltage thawj configuration
Txo ntawm - qhov yuav tsum tau hloov qhov chaw thiab ua kom yooj yim rau kev tswj cov khoom muag.
• Integrated Internal Fuse Device (IFD)
Muab kev tiv thaiv kev tiv thaiv sab hauv, txhim kho kev nyab xeeb kev ua haujlwm thiab txo kev pheej hmoo rau cov khoom siv nyob ib puag ncig.
• Siab zog efficiency
Kev ua tau zoo ntawm Ntau dua lossis sib npaug rau 98.83% pab txo qis dua - lub sijhawm ua haujlwm cov nqi.
• Optimized qis -tsim poob
Tsis muaj -load poob: 139 W
Load poob: 693 W
Ua kom ruaj khov thermal ua haujlwm thiab txhim khu kev qha ntev - lub sijhawm ua haujlwm.
Ua ke nrog ONAN cua txias thiab tus ncej ruaj khov- tsim qauv tsim, qhov kev daws teeb meem no ua tau raws li qhov xav tau ntawm Canadian nyiaj siv ua haujlwm faib khoom siv.
1.5 Cov duab kos
50kVA hluav taws xob transformer ntawm tus ncej kos duab thiab daim ntawv teev npe
![]() |
![]() |
02 Transformer Core Cheebtsam
2.1 Cua txias

Coil teeb: LV ntawv ci, HV hlau, sib tov ntawm tooj liab thiab txhuas. Ntawv ci kis tam sim no, sheds tshav kub. Hlau khoov, nyob twj ywm insulated. Copper-Aluminium blends hits efficiency thiab raug nqi. Durable. Ua haujlwm hauv nroog txoj kev, kab nyob deb nroog, txawm tias hnub twg cuam tshuam rau nws. Txhim khu kev ntseeg, ruaj khov, ua nws txoj haujlwm tsis muaj fuss.
2.2 9kV HV Arrester
Lub 9kV high voltage ntes yog ntsia los tiv thaiv lub transformer los ntawm xob laim surges thiab transient overvoltage xwm txheej tshwm sim nyob rau hauv overhead faib systems. Los ntawm kev txwv qhov hluav taws xob hluav taws xob ua ntej nws mus txog qhov rwb thaiv tsev sab hauv, tus ntes txo cov hluav taws xob kev ntxhov siab ntawm cov khoom tseem ceeb thiab txhim kho tag nrho cov khoom siv hluav taws xob ua haujlwm nyob rau hauv cov kev siv hauv zej zog.

2.3 Internal Fuse Device (IFD)

Internal Fuse Device (IFD) yog tsim los txiav tawm lub transformer sab hauv thaum muaj xwm txheej loj. Cov txheej txheem tiv thaiv no txo qhov kev pheej hmoo ntawm lub tank rupture, txwv tsis pub cuam tshuam, thiab txhim kho cov neeg ua haujlwm thiab kev nyab xeeb. Kev sib koom ua ke IFD ua raws cov kev cai siv hluav taws xob kev nyab xeeb rau ncej-mounted transformers hauv Canadian tis network.
2.4 Kev sib dhos zaum kawg
Nyob rau theem kawg ntawm kev sib dhos, cov khoom siv hluav taws xob hloov pauv tau ua tiav tag nrho, nrog rau cov tub ntxhais thiab cov windings ruaj ntseg sib sau ua ke thiab tag nrho cov khoom siv sab hauv tau raug welded thiab txuas nrog. Switching Cheebtsam yog ntsia thiab tsau nyob rau hauv txoj hauj lwm, tsim ib tug tiav transformer core los ua ke.

03 FAQ – Cov lus nug nquag nug
Q: Yuav ua li cas yog qhov dual -voltage thawj configuration xaiv los yog hloov?
A: Lub transformer yog nruab nrog dual -voltage thawj tsim, tso cai xaiv voltage los ntawm predefined kev sib txuas nrog rau thaum lub installation los yog commissioning.
Q: Puas yog qhov hloov pauv no haum rau cov kab noj zaub mov ntev nyob deb nroog?
A: Yog. Nrog optimized impedance (2.85% ± 10%) thiab kev ua haujlwm siab, lub transformer ua tau zoo ntawm cov kab hluav taws xob nyob deb nroog ntev.
Q: Lub tshuab hluav taws xob puas tuaj yeem hloov kho rau kev siv hluav taws xob tshwj xeeb?
A: Yog. Ib theem ncej mounted Transformer tuaj yeem hloov kho kom ua raws li IEC, ANSI / IEEE, CSA, RUS, thiab NEMA cov qauv, nrog cov kev xaiv yooj yim rau kev ntsuam xyuas, voltage, zaus, cua txias txoj kev, impedance, vector pawg, tank khoom, thiab accessories xws li xob laim ntes thiab IFD.
04 Ntim thiab thauj
4.1 Ntim


4.2 Shipping


Cim npe nrov: hluav taws xob transformer ntawm ncej, chaw tsim tshuaj paus, tsum, nqe, nqi
You Might Also Like
50 kVA Transformer Electric Ncej-13.8/0.347 kV|Canad...
37.5 kVA Transformers Ntawm Xov Tooj Ncej-34.5/0.12*...
25 kVA Transformer Light Ncej-13.8/0.24 kV|Guyane 2025
100 kVA Residential Transformer-13.8/0.12*0.24 kV|Gu...
167 kVA Ncej Mounted Distribution Transformer-24.94/...
25 KVA Ib Phase Ncej Transformer-25/0.347 KV|Canada ...
Xa kev nug