25 kVA Transformer Light Ncej-13.8/0.24 kV|Guyane 2025

25 kVA Transformer Light Ncej-13.8/0.24 kV|Guyane 2025

Lub Tebchaws xa khoom: Guyana 2025
Peev xwm: 25kVA
Lub hwj chim: 13.8kV-240/120V
Xa kev nug

 

 

image001

Kev ntseeg tau thiab ua tau zoo lub teeb ncej transformers yog tsim los rau kev siv hluav taws xob nyob deb nroog thiab kev faib tawm rau pej xeem!
 

01 General

1.1 Project Background

Xyoo 2025, peb cov neeg siv khoom ntev ntev hauv Guyana tau tso lwm qhov kev txiav txim ntau, suav nrog 50 units ntawm 25 kVA ib zaug -theem ncej- mounted transformers, nrog rau 50 kVA thiab 100 kVA qauv. Qhov kev yuav khoom rov qab no qhia txog lawv txoj kev ntseeg txuas ntxiv hauv qhov zoo thiab kev ua tau zoo ntawm peb cov khoom. Nrog rau kev thov kom muaj hluav taws xob nyob deb nroog, kev hloov kho vaj tse, thiab kev siv hluav taws xob tsis zoo, cov 25 kVA transformers yog qhov tshwj xeeb tshaj yog rau cov cheeb tsam qis uas muaj kev ruaj ntseg, kev cia siab, thiab kev ua haujlwm tseem ceeb.

Cov transformers no ua raws li IEEE & ANSI C57.12.00 tus qauv, muaj 13.8 kV thawj qhov hluav taws xob thiab 120/240 V dual cov zis tawm, ua nrog tooj liab windings, 2% impedance, thiab ± 2 × 2.5% tsis muaj -load tap changer. Nrog rau txoj kev ua kom txias ntawm ONAN, lawv muab kev lag luam txhim khu kev qha ntawm 60 Hz, tsis muaj -load poob ntawm 98 W thiab thauj khoom poob ntawm 289 W, ua rau lawv muaj zog- kev daws teeb meem zoo rau cov khoom siv hluav taws xob hauv thaj chaw deb. Lawv tuaj yeem ua haujlwm raws li lub teeb ncej transformers hauv cov teeb pom kev zoo rau pej xeem, chaw nres tsheb, lossis txoj kev- theem kev faib tawm, qhov loj me me thiab kev ua tau zoo yog qhov tseem ceeb.

Nrog rau ntau xyoo ntawm kev paub hauv kev tsim khoom siv hluav taws xob, peb tshwj xeeb hauv kev tsim thiab tsim ib qho -theem ncej- mounted transformers, muab cov kev daws teeb meem zoo heev kom tau raws li ntau hom kev thov. Peb cov khoom siv dav siv thoob plaws North thiab South America, txhawb nqa los ntawm kev ua raws li cov qauv thoob ntiaj teb, kev tswj xyuas zoo, thiab kev pabcuam teb.

 

 

1.2 Technical Specification

25kVA ib theem ncej mounted transformer specification thiab cov ntaub ntawv ntawv

Xa rau
Guyane
Xyoo
2025
Hom
Ib theem ncej mounted transformer
Txuj
IEEE & ANSI C57.12.00 Nws
Rated zog
25 kVA
Ntau zaus
60 tzs
Polarity
Kev rho tawm
Vector pawg
Ib 0
Thawj Voltage
13800 V
Secondary Voltage
120/240 V
Cov khoom siv winding
tooj liab
Impedance
2%
Txoj kev txias
ONAN
Coj mus rhaub Changer
NLTC
Tapping Range
± 2X2.5% (tag nrho ntau yam =10%)
Tsis Load Loss
98 W
Ntawm Load Loss
289 W
Khoom siv
Standard Configuration

 

1.3 Cov duab kos

25kVA ib theem ncej mounted transformer qhov ntev thiab cov ntsiab lus hnyav

image003

 

 

02 Kev tsim khoom

2.1 Core

Txhawm rau txhim kho kev ua haujlwm ntawm lub zog thiab kev cia siab rau kev ua haujlwm, cov koob no siv lub zog-txuag lub qhov txhab uas paub txog kev poob qis, tsis muaj suab nrov, thiab ua haujlwm ntev. Lub hauv paus tseem ceeb yog coated rau kev tiv thaiv - noo noo thiab tiv thaiv - kev tiv thaiv corrosion, ua kom muaj kev ruaj ntseg hauv qhov chaw sab nraum zoov.

image005

 

2.2 Cua txias

image007

Featuring ob lub HV bushings thiab peb LV bushings, no transformer siv tooj liab ntawv ci rau lub siab-voltage winding thiab tooj liab conductor hlau rau qhov tsawg-voltage sab. Tag nrho cov coils tau siv lub tshuab nqus tsev kom qhuav thiab rwb thaiv tsev kho mob kom ntseeg tau tias lub zog dielectric thiab kev ua haujlwm ruaj khov hauv cov huab cua sab nraum zoov.

 

2.3 Tank

Lub tank yog tsim los ntawm siab - zoo me me hlau thiab coated nrog epoxy xim rau superior corrosion kuj. Nws nta lub kaw lus tsim uas dhau qhov kev ntsuam xyuas airtightness, ua kom muaj kev sib khi zoo heev los tiv thaiv cov roj xau thiab ya raws. Ntsuas 885mm nyob rau hauv qhov siab, 660mm nyob rau hauv dav, thiab 580mm nyob rau hauv ntev, nws txhawb ONAN txias kom ruaj khov transformer ua hauj lwm thiab npaum kub dissipation.

image009

 

2.4 Kev sib dhos zaum kawg
image011

Thaum lub sij hawm sib dhos, lub siab -voltage bushings yog mounted rau saum thiab siv lub qhov muag ntsia liaj qhov rooj hom ntsuas ntawm 18 kV nrog ib tug xob laim impulse withstand voltage ntawm 125 kV, muab zoo heev creepage nrug thiab hluav taws xob rwb thaiv tsev. Qhov qis-voltage bushings yog sab-mounted, ntsuas ntawm 250 A. Lub siab nyem valve tseem raug teeb tsa, nrog rau kev tso tawm ntau ntawm 0.03 ± 0.01 MPa, ua kom muaj kev nyab xeeb nyob rau hauv qhov kub thiab txias lossis txawv txav sab hauv.

03 Ncej Transformer Parts

HV Bushing
LV Bushing
Tap Changer
Support Lugs
Pressure relief device
Grounding Terminal

 

04 Kev Xeem

Kev xeem Standard
• IEEE C57.12.20-2017
IEEE Standard for Overhead-Type Distribution Transformers 500 kVA thiab Me; High Voltage, 34500 V thiab hauv qab; Tsawg Voltage, 7970/13 800YV thiab hauv qab
• IEEE C57.12.90-2021
IEEE Standard Test Code rau Liquid-Immersed Distribution, Power, thiab Regulating Transformers
• CSA C802.1-13 (R2022)
Yam tsawg kawg nkaus Efficiency rau kua-Fulled Distribution Transformers

 

Cov txiaj ntsig Kev Xeem Ntawm Ib Ncej Hloov Hloov Los Ntawm 50-unit Batch

Tsis muaj.

Cov khoom kuaj

1

Kev ntsuas ntsuas

2

Kev ntsuas ntsuas

3

Kev ntsuam xyuas polarity

4 Tsis muaj -load poob thiab excitation tam sim no
5 Load poob, impedance voltage, tag nrho poob thiab efficiency
6 Applied Voltage Test
7 Induced Voltage Withstand Test
8 Rwb thaiv tsev Resistance Measurement
9 Kev Xeem Leakage
10 Roj Dielectric Test
image013
image015
 

05 Packing thiab Shipping

image017
image019
 

06 Site thiab Summary

Qhov no 25 kVA ib qho -theem ncej- mounted transformer yog ib feem ntawm kev txiav txim rov qab los ntawm ib tug ntev -cov neeg siv khoom nyob rau hauv Guyana, qhia txog peb cov khoom ua tau zoo ib yam thiab kev lag luam kev ntseeg siab. Tshwj xeeb yog tsim los rau kev faib hluav taws xob hauv zej zog thiab nyob deb nroog, nws yog qhov zoo tshaj plaws rau cov cheeb tsam uas xav tau kev ruaj ntseg, muaj txiaj ntsig, thiab cov kev daws teeb meem rau cov khoom siv qis qis xws li cov khoom siv hauv tsev, thaj chaw ua liaj ua teb, lub teeb ncej transformers, thiab tawm hauv - kab sib chaws hauv zej zog.

Ua kom tau raws li cov qauv thoob ntiaj teb, lub tshuab hloov hluav taws xob tau tsim kho rau qhov chaw sab nraum zoov hnyav, nrog kev txhim kho rwb thaiv tsev, corrosion- tiv thaiv kev tsim kho, thiab kev ua kom txias. Nws lub tank kaw tsim thiab ua tau zoo- cov khoom siv kuaj xyuas kom muaj kev nyab xeeb thiab ruaj khov nyob rau hauv cov xwm txheej nyuaj xws li cov av noo thiab kub hloov pauv.

Nrog kev loj hlob ntawm kev tsim kho vaj tse hauv Latin America thiab nce kev thov rau cov khoom siv hluav taws xob hauv cheeb tsam, lub tshuab hloov pauv no sawv cev rau qhov ua tau zoo, lub zog - kev xaiv zoo rau kev nthuav dav thiab txhim kho kev sib txuas hauv thaj chaw deb lossis tsis tau txais kev pab.

25 kVA transformer light pole

 

 