1000 kVA Residential Pad Mounted Transformer-22.86/0.48 Kv| USA 2024

1000 kVA Residential Pad Mounted Transformer-22.86/0.48 Kv| USA 2024

Lub teb chaws: America 2024
Peev xwm: 1000KVA
Qhov hluav taws xob: 22.86 / 0.48kV
Feature: nrog surge arrester
Xa kev nug

 

 

mount transformer

Cov thev naus laus zis tshiab, lub zog zoo -- peb-theem pad-mounted transformer, tsav kev txhim kho kom ruaj khov!

 

01 General

1.1 Project Background

1000 kVA ncoo mounted transformer tau xa mus rau Asmeskas xyoo 2024. Lub zog ntsuas ntawm lub tshuab hloov pauv yog 1000 kVA nrog ONAN txias. Thawj qhov hluav taws xob yog 22.86GrdY / 13.2kV ​​nrog ± 2 * 2.5% tapping ntau yam (NLTC), qhov nruab nrab voltage yog 0.48 / 0.277kV, lawv tsim ib pawg vector ntawm YNyn0, thiab nws yog lub voj pub thiab tuag pem hauv ntej transformer.

Lub siab -voltage terminals ntawm no peb theem pad mounted transformer yog nruab nrog pub-thru insert, tsim los txuas lub luj tshib cable plugs los yog tag nrho cov insulated luj tshib surge arresters. Qhov kev tsim no ua tiav sealing qhov chaw nyob hauv cov khoom siv insulating, tsim kom muaj cov qauv insulated tag nrho. Lub davhlau ya nyob twg nto tseem tsis yog -kev coj ua (hauv av muaj peev xwm), ua kom cov neeg ua haujlwm nyab xeeb. Thaum muaj xwm txheej ceev, lub ntsaws cable tuaj yeem kub -swapped nyob rau hauv tag nrho transformer load, yog li pab raws li ib tug load hloov yog xav tau.

Tsis tas li ntawd, nyob - kab qhia lossis qhov ntsuas qhov yuam kev tuaj yeem ntsia tau rau ntawm cov kab txuas txuas raws li kev ua haujlwm yuav tsum tau saib xyuas qhov xwm txheej lossis nrhiav qhov tsis raug. Ntawm qhov siab -voltage pem hauv ntej chamber phab ntsa ntawm lub transformer, nyob ze ntawm lub high-voltage bushing, ib phab ntsa-mounted fixture yog welded kom ruaj ntseg xaiv sawv- tawm insulated bushing connectors. Thaum lub plug cable raug tshem tawm thaum muaj zog, nws tuaj yeem muab tso rau hauv qhov muag tam sim ntawd -tawm bushing connector los xyuas kom meej kev ruaj ntseg thiab kev ruaj ntseg system.

 

 

1.2 Technical Specification

1000 KVA transformer specifications hom thiab cov ntaub ntawv

Xa rau
Asmeskas
Xyoo
2024
Hom
Pad mounted transformer
Txuj
IEEE Std C57.12.34-2022
Rated zog
1000KVA ua
Ntau zaus
60 tzs
Theem
3
Pub
Loop
Pem hauv ntej
Tuag
Hom cua txias
ONAN
Thawj Voltage
22.86 GRDY/13.2 KV
Secondary Voltage
0.48/0.277 KV
Cov khoom siv winding
Aluminium
Angular tshem tawm
yNyj 0
Impedance
5.75%(±7.5%)
Coj mus rhaub Changer
NLTC
Tapping Range
±2*2.5%
Tsis Load Loss
1.095 kWm
Ntawm Load Loss
7, 855 kWm
Khoom siv
Standard Configuration

 

1.3 Cov duab kos

1000 KVA ncoo mounted transformer daim duab kos duab thiab loj.

three phase transformer diagram three phase transformer nameplate

 

 

02 pad mounted transformer Accessories

2.1 Bay-O-Net Fuse

Lub tshuab hloov pauv siv Bay-O-Ntev tshem tawm fuse ntawm sab xub ntiag, muab kev tiv thaiv overcurrent yooj yim uas haum zoo rau kev ua haujlwm niaj hnub. Nws tshem tawm cov kev ua txhaum cai hauv nws lub peev xwm thiab tso cai rau kev hloov pauv yooj yim thaum xav tau. Ua hauj lwm ua ke nrog rau sab hauv tam sim no - txwv fuse, nws tsim ib qho kev sib koom ua ke tiv thaiv teeb tsa uas tswj kev ua haujlwm ruaj khov nyob rau hauv ib txwm muaj thiab nruab nrab qhov ua txhaum loj.

Bay-O-Net Fuse

 

2.2 Tam sim no txwv fuse

Current Limit Fuse

 

Ib qho tam sim no sab hauv- txwv fuse raug teeb tsa los daws qhov siab - lub zog thawj qhov ua txhaum uas tshaj qhov cuam tshuam ntawm Bay -O-Net fuse. Nws teb sai, txwv tsis pub tam sim no thiab txo cov thermal stress ntawm windings. Los ntawm kev khiav hauj lwm nyob rau hauv series nrog lub fuse expulsion, lub CL fuse muab ib tug thib ob tiv thaiv txheej, kom ntseeg tau tias lub transformer muaj peev xwm tiv taus tej yam kev txhaum loj heev thaum tswj kev ruaj ntseg system thiab ntev - lub sij hawm durability.

 

2.3 25 kV Lub luj tshib Arrester

Lub transformer yog nruab nrog lub luj tshib 25 kV - hom surge arrester txuas los ntawm lub loadbreak interface. Nws muab kev tiv thaiv tsis tu ncua tiv thaiv xob laim surges thiab hloov pauv hloov pauv uas yuav tshwm sim ntawm thawj kab. Tus neeg ntes pab ua kom lub rwb thaiv tsev nyob hauv qhov txwv tsis pub muaj kev nyab xeeb, txhawb kev ua haujlwm ruaj khov nyob rau hauv ib puag ncig kev faib khoom, thiab tswj xyuas qhov kev ntseeg tag nrho uas xav tau los ntawm cov neeg tuag- pem hauv ntej ncoo- cov khoom siv.

25 KV Elbow Arrester
 

 

03 Kev Xeem

Tsis muaj.

Cov khoom kuaj

1

Kev ntsuas ntsuas

2

Kev ntsuas ntsuas

3

theem- kev xeem sib txheeb

4 Tsis muaj -load poob thiab excitation tam sim no
5 Load poob impedance voltage thiab efficiency
6 Applied Voltage Test
7 Induced Voltage Withstand Test
8 Kev Xeem Leakage
9 Rwb thaiv tsev Resistance Measurement
10 Roj Xeem

 

Applied Voltage Test of transformer
Induced Voltage Withstand Test of transformer

 

 

04 Packing thiab Shipping

 

packing of mount transformer
mount transformer transportation

 

05 Site thiab Summary

Hauv kev xaus, peb peb -theem ncoo-mounted transformers sawv ntawm lub hauv ntej ntawm kev txhim khu kev qha thiab muaj txiaj ntsig kev faib hluav taws xob daws teeb meem. Tsim los nrog cov thev naus laus zis siab tshaj thiab kev ua haujlwm zoo tshaj plaws, cov tshuab hloov pauv no muab kev ua haujlwm tsis sib xws thiab kev nyab xeeb rau ntau yam kev siv. Txawm hais tias kev lag luam, kev lag luam, lossis kev siv hluav taws xob xav tau, peb cov transformers kom ruaj khov xa hluav taws xob, txhim khu kev ua haujlwm, thiab txhawb kev ruaj khov. Cia siab rau peb txoj kev cog lus rau kev ua tau zoo thiab kev tsim kho tshiab los txhawb koj lub neej yav tom ntej kom zoo. Tiv tauj peb hnub no kom paub ntau ntxiv txog yuav ua li cas peb peb -theem pad-mounted transformers tuaj yeem ua tau raws li koj cov kev xav tau ntawm lub zog!

power distribution solutions

 

Cim npe nrov: nyob hauv ncoo mounted transformer, chaw tsim tshuaj paus, tsum, nqe, nqi