Qhia rau Delta thiab Wye Transformer Kev Sib Txuas
May 08, 2026
Tso lus

1. Taw qhia
Peb-theem hluav taws xob faib hluav taws xob muaj kev vam khom ntau ntawm ob hom kev hloov pauv hloov pauv: Delta (Δ) thiab Wye (Y). Cov kev teeb tsa no txiav txim siab seb qhov hluav taws xob thiab qhov hluav taws xob xa mus li cas, kev thauj khoom tuaj yeem txuas nrog li cas, thiab qhov system teb li cas rau qhov tsis raug thiab qhov tsis sib xws. Kev nkag siabKev sib txuas ntawm Delta thiab WyeNws yog ib qho tseem ceeb rau cov kws tsim hluav taws xob, cov thawj coj hauv tsev, thiab cov kws tshaj lij uas tsim, ua haujlwm, lossis tswj cov tshuab hluav taws xob.
Phau ntawv qhia no suav nrog cov yam ntxwv, qhov zoo, kev txwv, thiab kev siv tswv yim ntawm txhua hom kev sib txuas, nrog rau kev sib xyaw ua ke feem ntau thiab cov qauv xaiv.
2. Nkag siab txog kev sib txuas ntawm Delta thiab Wye

2.1 Wye kev twb kev txuas
Hauv kev sib txuas ntawm Wye (lossis Hnub Qub), ib qho kawg ntawm txhua qhov ntawm peb qhov kev hloov pauv hloov pauv tau txuas nrog lub ntsiab lus tseem ceeb hu ua qhov nruab nrab. Lwm qhov kawg txuas mus rau peb theem kab, tsim cov duab zoo ib yam li tsab ntawv "Y". Qhov kev teeb tsa no tsim muaj plaub -kab kab hluav taws xob- peb theem conductors ntxiv rau tus neeg xyuas pib nruab nrab.
Lub ntsiab lus nruab nrab muaj ob qhov sib txawv voltage: kab - mus rau - kab hluav taws xob (feem ntau siab dua) thiab kab - rau - nruab nrab voltage (qis). Piv txwv li, 480Y / 277V wye system muab 480V ntawm theem rau peb -theem khoom thiab 277V los ntawm ib theem mus rau nruab nrab rau ib zaug -theem loads. Kev sib raug zoo lej yog qhia raws li
, txhais tau tias cov kab hluav taws xob yog kwv yees li 1.732 npaug ntawm theem voltage.
Wye kev sib txuas kuj tseem tso cai rau hauv av ntawm qhov nruab nrab ntawm qhov nruab nrab, uas tsim kom muaj kev siv hluav taws xob ruaj khov thiab tsim kom muaj -impedance rov qab txoj hauv kev rau qhov txhaum tam sim no. Qhov nruab nrab tuaj yeem ua kom muaj zog hauv av, hauv av los ntawm kev tiv thaiv, lossis sab laug ntab nyob ntawm qhov yuav tsum tau ua. Txawm li cas los xij, yog tias qhov nruab nrab tsis muaj qhov tsis sib xws los yog ua tsis raug, kev ua txhaum cai poob qis heev thiab qhov kev sib tw tsis tau xav txog yuav ua rau cov khoom puas.
2.2 Kev sib txuas ntawm Delta
Ib qho kev sib txuas ntawm Delta koom nrog txhua qhov kev hloov pauv winding kawg - mus rau - kawg los ua ib lub voj voos kaw. Txhua lub ces kaum ntawm daim duab peb sab ua qhov taw tes sib txuas rau ib theem kab. Tsis zoo li Wye system, Delta tsis muaj qhov nruab nrab - nws yog peb - xov hlau nrog tsuas yog peb theem conductors.

Hauv kev teeb tsa Delta, cov kab hluav taws xob sib npaug sib npaug ntawm cov theem hluav taws xob thoob plaws txhua qhov cua, thaum cov kab tam sim no raug faib tawm xws li txhua theem winding yog kwv yees li 58% (
) ntawm kab tam sim no. Qhov kaw - lub voj voog tsim muaj zog tam sim no thiab kev ua haujlwm zoo heev hauv cov khoom hnyav. Txawm hais tias ib zaug xwb -theem chav nyob hauv Delta lub txhab nyiaj tsis ua haujlwm, ob qho ntxiv tuaj yeem xa peb mus ntxiv -theem fais fab ntawm kwv yees li 58% ntawm lub peev xwm qub- feem ntau hu ua "qhib-delta" ua haujlwm.
Qhov tsis muaj cov ntsiab lus nruab nrab ua kom yooj yim siab -faiv peb-theem xa tawm tab sis ua rau muaj kev txwv: Delta kev sib txuas tsis tuaj yeem muab ib qho -theem loads ncaj qha yam tsis muaj cov cuab yeej ntxiv, thiab hauv av yuav tsum muaj txoj hauv kev tshwj xeeb vim tias tsis muaj qhov nruab nrab nruab nrab.
3. Qhov txawv tseem ceeb ntawm ib saib
|
Feature |
Delta (Δ) |
Yog (Y) |
|
Kev teeb tsa |
Kaw daim duab peb sab voj |
Lub hnub qub zoo nrog nruab nrab nruab nrab |
|
Hlau |
3-xaim system (theem nkaus xwb) |
4-wire system (+ nruab nrab) |
|
Voltage kev sib raug zoo |
|
|
|
Neutral point |
Tsis muaj nyob |
Muaj (yuav tsum grounded) |
|
Tib -theem muaj peev xwm |
Tsis tuaj yeem muab ib qho -theem loads ncaj qha |
Dual voltage rau ib zaug -theem thiab peb-theem |
|
Harmonic mitigation |
Traps triplen harmonics sab hauv |
Muaj kev cuam tshuam ntau dua (yuav tsum tau txo qis) |
|
Ua txhaum cai |
Txuas ntxiv qhib -delta tom qab ib lub kauj tsis ua haujlwm |
Nyob ntawm nruab nrab grounding configuration |
|
Tej kev siv |
High -voltage kis tau tus mob, hnyav industrial motors |
Distribution systems, mix-siv vaj tse, chaw ua lag luam |
Cov lus qhia tau hais tias Delta tseem ceeb tshaj qhov muaj zog thiab ua haujlwm tau zoo rau peb qhov hnyav -theem loads, thaum Wye muaj ntau yam thiab muaj kev nyab xeeb rau hauv av rau cov tshuab nrog cov khoom sib xyaw.
4. Combined Transformer Configurations
Transformers tuaj yeem ua ke Delta thiab Wye ntawm lawv cov thawj thiab theem nrab windings nyob rau hauv plaub txoj kev. Thawj hom winding yog teev ua ntej (H sab, sab saud), ua raws li qhov thib ob winding hom (X sab, ntawv qis).
4.1 Delta-Wye (Δ-Y)
Qhov no yog qhov feem ntau siv peb -theem transformer kev twb kev txuas. Lub hauv paus yog Delta- teeb tsa, thaum lub thib ob siv Wye kev sib txuas, feem ntau nrog qhov nruab nrab hauv av.
Yog vim li cas Nws thiaj li nrov:Lub Delta thawj cais cov dej ntws los ntawm cov dej ntws qis thiab kev sib haum xeeb. Txhua qhov nruab nrab tam sim no tsim los ntawm qhov tsis sib npaug ntawm ib qho - theem loads ntawm lub thib ob sab circulate nyob rau hauv lub Delta winding es tsis rov qab mus rau lub hauv paus ntsiab lus. Qhov no tsim kom muaj hluav taws xob huv si ciam teb-sab sauv pom qhov sib npaug peb- cov kab hluav taws xob, thaum cov dej hauv qab tuaj yeem ua haujlwm sib xyaw ib zaug -theem thiab peb-theem loads nrog qhov nruab nrab ruaj khov.
Cov ntawv thov raug:Cov khoom siv hluav taws xob qis qis qis qis qis (13.8 kV, 34.5 kV) mus rau theem faib (208Y / 120V, 480Y / 277V); cov tsev lag luam uas xav tau ob qho tib si peb -theem lub cev muaj zog thiab 120V teeb pom kev zoo; cov nroj tsuag muaj kev noj qab haus huv theem nrab faib panels; thiab cov chaw khaws ntaub ntawv xav tau kev nkag mus rau nruab nrab ruaj khov rau cov khoom siv IT. Ib qho 208Y / 120V theem nrab yog ze li ntawm txhua qhov chaw hauv North American chaw lag luam.
Qhov zoo:
- Muab lub hauv paus nruab nrab rau kev nyab xeeb ib zaug -theem loading
- Cais lub hauv paus system los ntawm theem nrab harmonics (triplen harmonics daig hauv Delta)
- Tuav cov loads tsis sib npaug zoo yam tsis muaj qhov cuam tshuam loj heev
- Ua kom muaj txiaj ntsig cov kauj ruam -down voltage transformation
Kev txwv:Qhia txog 30-degree theem hloov ntawm thawj thiab theem nrab voltages (sib tham hauv qab no), uas yuav tsum tau txiav txim siab thaum uas tig mus transformers. Tsis tas li ntawd, Delta primaries tsis tuaj yeem muab qhov nruab nrab rau cov kab dej ntws.

4.2 Wye-Delta (Y-Δ)
Nrog rau Wye thawj thiab Delta theem nrab, qhov kev teeb tsa no feem ntau yog siv hauv kauj ruam -cov ntawv sau cia uas thawj xav tau kev sib txuas nruab nrab, lossis hauv kauj ruam - nce daim ntawv thov thaum thim rov qab lub transformer.
Daim ntawv thov:Qhov no tuaj yeem pom nyob rau hauv loj - kauj ruam piv - down transformer xwm txheej los pub muaj lub cev muaj zog loads los yog nyob rau hauv lub cev muaj zog oob khab circuits rau loj motors. Hauv daim ntawv thov pib lub cev muaj zog, cov squirrel loj- lub tawb lub cev muaj zog qee zaum txuas nrog Wye rau kev pib (txo qis tam sim no mus rau kwv yees li ib- feem peb ntawm ib txwm) thiab tom qab ntawd hloov mus rau Delta rau kev khiav, uas feem ntau hu ua "Wye-Delta lossis Hnub Qub-Delta starter".
Qhov zoo:
- Primary Wye muab qhov nruab nrab nruab nrab rau cov av pem hauv ntej yog tias xav tau
- Thib ob Delta muab cov txiaj ntsig zoo ib yam li Delta- muaj zog peb- theem tso tawm, ua txhaum kev zam nrog qhib -delta muaj peev xwm, thiab triplen harmonic cais
- Zoo rau cov ntawv thov uas xav tau siab pib lub zog los yog ntxuav peb -theem fais fab tsis muaj qhov nruab nrab
Kev txwv:Qhov thib ob Delta tsis tuaj yeem muab ib qho - theem thauj khoom ncaj qha yam tsis muaj khoom siv ntxiv. Sib npaug cov loads ntawm thawj qhov nruab nrab thaum pub mis rau Delta theem nrab tuaj yeem nyuaj.

4.3 Delta -Delta (Δ-Δ)
Nrog rau ob qho tib si thawj thiab theem nrab hauv Delta, qhov kev teeb tsa no muaj kev ua tau zoo peb -theem kev ua tau zoo thiab muaj peev xwm ua haujlwm txuas ntxiv hauv qhib -delta hom ntawm kev txo qis yog tias ib lub kauj tsis ua haujlwm. Nws yog qhov zoo- haum rau qis-voltage, siab- daim ntawv thov tam sim no qhov twg peb -theem loads dominate thiab qhov xav tau rau qhov nruab nrab yog tsawg, xws li cov khoom siv lub cev muaj zog thiab cov khoom siv vuam. Txawm li cas los xij, nws tsis muaj kev sib txuas nruab nrab ntawm ob sab thiab yog li tsis tuaj yeem ua haujlwm ncaj qha rau ib leeg -theem kab- rau- nruab nrab loads.

4.4 Wye-Wye (Y-Y)
Wye-Wye yog qhov kev teeb tsa kev lag luam tshaj plaws, muab cov ntsiab lus nruab nrab ntawm ob sab thiab tsis muaj theem hloov ntawm qhov nruab nrab thiab theem nrab voltages, uas yooj yim rau kev sib piv ntau lub tshuab hloov pauv. Nws ua haujlwm zoo rau cov khoom sib npaug thiab cov tshuab uas xav tau nruab nrab ntawm cov dej ntws thiab cov dej ntws. Txawm li cas los xij, Wye-Wye transformers muaj kev cuam tshuam ntau dua rau cov teeb meem sib haum xeeb tshwj tsis yog cov thawj nruab nrab yog cov hauv paus ruaj khov lossis ib qho tertiary Delta winding ntxiv. Ua tib zoo ntsuas qhov ntsuas yuav tsum tau tiv thaiv kom tsis txhob muaj overloading los ntawm qhov tsis sib npaug ntawm ib qho -theem loads.


5. Voltage thiab tam sim no kev sib raug zoo
Cov lem piv xam txawv nyob ntawm qhov configuration:
Delta-Wye (Δ-Y):Rau ib kauj ruam -down delta-wye transformer nrog ib tug lem ratio ntawm N (primary mus rau theem nrab ib coil), lub thib ob kab voltage yog
. Hloov pauv, kev suav suav nrog a
yam vim yog kev hloov pauv ntawm Delta kab voltage mus rau Wye kab - mus rau - nruab nrab voltage.
Wye-Delta (Y-Δ):Rau wye-delta transformer, cov kab hluav taws xob theem nrab cuam tshuam rau thawj theem voltage los ntawm qhov sib piv, tab sis ntxiv
kev sib raug zoo siv nyob ntawm seb koj tab tom nqis los yog nce qib.
Delta-Delta (Δ-Δ) thiab Wye-Wye (Y-Y):Rau tib yam -kev sib txuas configurations, qhov voltage transformation ua raws li qhov yooj yim lem piv:
, nrog kab voltages scaling ncaj qha.
6. Kev txiav txim siab hauv av
Grounding yog qhov sib cav tseem ceeb tshaj plaws thaum xaiv ntawm Delta thiab Wye.
Wye Grounding Options:Thaum muaj Wye nruab nrab, tuaj yeem yog:
- Solidly grounded:Txuas ncaj qha rau lub ntiaj teb (feem ntau yog rau cov voltages hauv qab 600V). Qhov no muab qhov qis tshaj impedance txhaum rov qab txoj kev.
- Resistance grounded:Nruab nrab txuas rau hauv av los ntawm ib qho kev tiv thaiv uas txwv cov av txhaum tam sim no rau tus nqi predetermined, feem ntau 5-400 amperes. Qhov no txo cov kev puas tsuaj thaum lub sij hawm faults thaum tseem muab relaying rhiab heev.
- Ungrounded los yog reactance grounded:Qhov nruab nrab tseem raug cais tawm hauv av los yog txuas nrog lub reactor. Tsis tshua muaj nyob hauv cov tsev nyob niaj hnub lossis kev lag luam niaj hnub tab sis pom muaj nyob hauv qee qhov chaw ua lag luam lossis siab -kev tiv thaiv hauv av.
Hauv kev hloov ua qauv, qhov kev txiav txim siab rau qhov nruab nrab ntawm Wye kev sib txuas ncaj qha cuam tshuam rau kev xaiv ntawm cov khoom siv hluav taws xob, cov neeg tua hluav taws, cov bushings, thiab lwm yam. Rau hauv av Wye systems, cov khoom raug xaiv raws theem - mus rau - av voltage. Rau cov tshuab tsis muaj av, cov khoom siv yuav tsum raug ntsuas rau theem - mus rau - theem voltage.
Delta Grounding Challenges:Yog tsis muaj lub ntsiab lus nruab nrab, Delta systems tsis tuaj yeem nyob hauv ib yam li Wye systems. Hloov chaw:
- Pob zeb grounding:Ib theem tus neeg xyuas pib yog txhob txwm txuas rau hauv av- txoj kev yooj yim tshaj plaws tab sis tsim cov hluav taws xob siab ntawm ob theem piv rau hauv av.
- Center-tapping grounding:Hauv qee qhov Delta thib ob, qhov nruab nrab ntawm ib qho winding tuaj yeem yog qhov nruab nrab -tapping thiab hauv av los muab kev txwv ib zaug xwb -theem muaj peev xwm, xws li hauv 240/120V peb-theem plaub-wire delta systems (tseem hu ua "high-ceg delta").
- Grounding transformers: A Zig-zaglos yog Wye-Delta grounding transformer tuaj yeem muab ntxiv los tsim ib qho khoom nruab nrab rau hauv av uas twb muaj lawm Delta system uas twb muaj lawm.

Daim ntawv ceeb toom kev nyab xeeb:Lub hauv paus ruaj khov Wye nruab nrab muab qhov qis -impedance txoj hauv kev rau hauv av txhaum tam sim no, tso cai rau lub Circuit Court breakers thiab fuses kom tshem tau qhov txhaum sai. Qhov no yog qhov laj thawj tseem ceeb ntawm Wye cov tsev kawm ntawv qib siab tau nyiam rau cov tsev lag luam, chaw kho mob, thiab lwm qhov chaw uas muaj kev ua txhaum cai thiab kev nyab xeeb ntawm cov neeg ua haujlwm yog qhov tseem ceeb.
7. Phase Shift hauv Delta-Wye thiab Wye-Delta Transformers
Ib qho tseem ceeb ntawm kev ua haujlwm tsis zoo: hauv Delta-Wye thiab Wye-Delta transformers, thawj thiab theem nrab voltages ib txwm hloov los ntawm 30 degrees. Qhov kev hloov theem no tshwm sim tsis nyob rau hauv windings lawv tus kheej tab sis vim li cas cov windings yog interconnected. Tshwj xeeb, txoj kab - mus rau - kab hluav taws xob ntawm Wye sab yog hloov 30 degrees piv rau kab - mus rau - kab hluav taws xob ntawm Delta sab.
Clock Notation (Vector Groups):Cov kev sib txuas ntawm Transformer feem ntau sau npe siv cov cim moos los qhia txog theem hloov pauv -piv txwv li, "Dy11" txhais tau tias yog Delta thawj (D), Wye theem nrab (y), nrog rau theem hloov mus rau 11 teev ntawm lub moos, lossis 330 degrees (sib npaug rau -30 degrees). "Yd1" txhais tau hais tias theem nrab lags thawj los ntawm 30 degrees.
Vim li cas Phase Shift Matters:Lub 30-degree theem hloov tsis yog ib qho teeb meem nyob rau hauv feem ntau installation, tab sis nws yuav ua ib qho tseem ceeb thaum uas tig mus transformers. Yog hais tias ob lub transformers nrog ntau pawg vector txuas nrog nyob rau hauv parallel, loj circulating currents yuav tshwm sim. Thaum txuas cov transformers nyob rau hauv parallel, pawg vector yuav tsum sib phim lossis raug them kom raug. Piv txwv li, Dy11 qee zaum tuaj yeem ua ke nrog Yd1 yog tias qhov kev hloov pauv hloov tau tsim nyog.
Phase hloov yog tsis muajhauv Delta-Delta thiab Wye-Wye kev sib txuas, uas yooj yim rau kev sib piv.
8. Kev xav txog kev sib raug zoo
Delta windings ua lub luag haujlwm tseem ceeb hauv kev tswj hwm kev sib haum xeeb. Triplen harmonics (thib peb, cuaj, kaum tsib, thiab lwm yam) yog ib txwm raug daig thiab ncig hauv Delta windings es tsis yog propagating rau cov khoom siv. Cov yam ntxwv no ua rau Delta-Delta thiab Delta-Wye configurations tshwj xeeb tshaj yog muaj txiaj ntsig zoo ntawm kev tiv thaiv kev sib haum xeeb ntawm cov khoom tsis sib xws los ntawm kev cuam tshuam rau cov kab nruab nrab.
Wye-Wye transformers muaj kev cuam tshuam ntau dua kom dhau lub suab nrov ntawm qhov chaw thiab thauj khoom. Vim li no, thaum Wye-Wye kev twb kev txuas yog xav tau rau lwm yam laj thawj, tertiary Delta winding qee zaum ntxiv los muab cov kev sib raug zoo triplen ib txoj hauv kev mus ncig.
9. Yuav ua li cas xaiv txoj cai Configuration
Xaiv qhov zoo tshaj plaws transformer configuration rau ib daim ntawv thov yuav tsum balancing ob peb yam:
9.1 Load Hom thiab Diversity
Ntshiab peb -theem loads (cov motors loj, cov khoom siv hnyav, cov khoom siv vuam) ua haujlwm zoo nrog txhua qhov kev teeb tsa, tab sis Delta-Delta muab kev ua txhaum cai thiab muaj peev xwm ua haujlwm txuas ntxiv hauv qhib -delta tom qab ua tsis tiav. Cov khoom sib xyaw uas xav tau ob qho tib si peb -theem thiab ib zaug-theem fais fab yog qhov zoo tshaj plaws los ntawm Delta-Wye configuration, uas muab lub hauv paus nruab nrab rau ib zaug -theem faib thaum cais cov thawj los ntawm qhov tsis sib xws.
9.2 Cov kev cai hauv av
Yog tias qhov nruab nrab hauv nruab nrab yog qhov tseem ceeb rau kev tiv thaiv kev tiv thaiv thiab kev tshem tawm qhov txhaum, ib qho Wye thib ob yog qhov tsim nyog. Delta-Wye yog qhov kev xaiv ntuj tsim rau kev faib khoom uas xav tau qhov chaw ruaj khov, hauv av nruab nrab ntawm sab load. Yog tias lub kaw lus tsis xav tau qhov nruab nrab thiab tuaj yeem ua haujlwm tsis muaj av lossis nrog lub kaum sab xis, Delta-Delta yuav tsim nyog.
9.3 Cov ntsiab lus Harmonic
Cov kab ke uas muaj kev sib haum xeeb tseem ceeb - ua cov khoom thauj (variable zaus tsav, hloov cov khoom siv fais fab, LED teeb pom kev zoo,data centercov khoom siv) tau txais txiaj ntsig los ntawm kev sib haum xeeb - muaj peev xwm ntawm kev sib tsoo ntawm Delta winding. Delta-Wye lossis Delta-Delta configurations raug pom zoo nyob rau hauv cov xwm txheej zoo li no.
9.4 Pib Yuav Tsum Tau Rau Cov Tsav Tsheb Loj
Cov motors loj uas yuav tsum tau txo qis -voltage pib yuav haum Wye-Delta pib kev npaj, qhov twg lub cev muaj zog pib hauv Wye kom txwv tsis pub dhau tam sim no thiab tom qab ntawd hloov mus rau Delta khiav.
9.5 Qhov System Voltage Levels thiab Kauj Ruam -Up vs. Kauj Ruam -Down
Delta-Wye feem ntau yog siv rau kauj ruam- nqes kev siv los ntawm nruab nrab-voltage tis mus rau qis- siv hluav taws xob. Wye-Delta feem ntau siv rau cov kauj ruam- nqes ib yam nkaus, tab sis qhov kev xaiv ntawm lawv tuaj yeem nqes mus seb puas xav tau qhov nruab nrab ntawm thawj lossis theem nrab.
9.6 Yav Tom Ntej Expandability thiab Redundancy
Delta-Delta configurations tso cai rau qhib-delta thaub qab- yog tias ib qho kev hloov pauv hauv lub txhab nyiaj tsis ua haujlwm, ob qho ntxiv tuaj yeem xa tawm kwv yees li 58% ntawm qhov ntsuas peb -theem peev. Qhov no tuaj yeem yog qhov tseem ceeb rau cov chaw tseem ceeb.
10. Cov ntsiab lus
Kev sib txuas ntawm Delta thiab Wye txhua tus ua haujlwm sib txawv hauv peb -theem fais fab kev faib tawm, thiab lawv cov Delta sib xyaw ua ke-Wye configuration yog kev lag luam ua haujlwm rau kev nce qib kev sib kis mus rau qib uas siv tau qhov chaw ruaj khov thiab cov khoom sib xyaw. Delta excels qhov twg muaj zog peb -theem xa hluav taws xob thiab kev ua txhaum cai yog qhov tseem ceeb, kaw- lub voj tsim muab kev sib koom ua ke zoo heev, thiab qhov tsis muaj qhov nruab nrab tsis yog qhov txwv. Wye ua tau zoo tshaj qhov uas muaj ntau yam, kev ua haujlwm hauv av, thiab sib xyaw ib zaug -theem ntxiv rau peb-theem loads yuav tsum tau, muab cov peev xwm dual voltage thiab siv nruab nrab ruaj khov.
Lub ntsiab lus sib ntsib tshaj plaws ntawm ob lub ntiaj teb no yog Delta -Wye transformer: Delta thawj cais cov dej ntws los ntawm cov dej ntws tsis sib xws thiab kev sib haum xeeb, thaum Wye theem nrab muab lub hauv paus, ruaj khov nruab nrab rau tiag tiag - lub ntiaj teb loads uas tsis tshua muaj kev sib npaug. Kev nkag siab thaum twg thiab vim li cas thiaj siv txhua qhov kev teeb tsa tso cai rau cov kws ua haujlwm ua haujlwm kom zoo dua qub, tswj hwm ntau hom kev thauj khoom zoo, thiab tswj cov nqi tsim khoom. Thaum muaj kev tsis ntseeg, tag nrho -ib puag ncig daim duab rau kev nqis qis zog rau kev sib xyaw- siv cov chaw feem ntau yog Delta-Wye, vim nws muaj qhov sib npaug zoo tshaj plaws ntawm kev siv ntau yam, kev nyab xeeb, thiab kev ua haujlwm.
11. Ib lo lus ntawm kev nyab xeeb
Ib txwm ua raws li tag nrho cov cai siv hluav taws xob thiab cov qauv kev nyab xeeb thaum ua haujlwm nrog transformers. Tsis txhob xav tias qhov system yog de-energized yam tsis muaj kev sim kom raug. Kev tiv thaiv overcurrent thiab grounding kom raug yog qhov tseem ceeb rau kev ua haujlwm nyab xeeb. Yog tias koj tsis paub meej txog txhua yam ntawm kev xaiv transformer lossis kev teeb tsa, sab laj nrog tus kws tshaj lij hluav taws xob muaj ntawv tso cai lossis tus kws tshaj lij.