75 KVA Tuag Pem Hauv Ntej Transformer-22.86/0.48 KV|USA 2024

75 KVA Tuag Pem Hauv Ntej Transformer-22.86/0.48 KV|USA 2024

Lub Tebchaws xa tuaj: Tebchaws Asmeskas 2024
Peev xwm: 75kVA
Qhov hluav taws xob: 22.86GrdY / 13.2-0.48kV
Feature: Tsib - ceg ceg
Xa kev nug

 

75 kva pole mounted transformer-front-door-open

Tsib- ceg txheem tsim kom muaj kev ruaj ntseg zoo dua thiab ua haujlwm zoo - siab - kev ua tau zoo tuag pem hauv ntej transformer tsim rau kev nyab xeeb thiab txhim khu kev qha fais fab

 

 

01 General

1.1 Project Description

Cov no75 kVA peb-theem ncoo-mounted transformerstau tsim los ntawm Scotech. Lawv raug xa mus rau Tebchaws Meskas hauv 2024. Lawv ua tau raws li IEEE / ANSI cov qauv thiab ua haujlwm zoo nrog North American tis systems. Pem hauv ntej-compartment, tuag-pem hauv ntej tsim tshem tawm qhov chaw nyob thiab muab kev nyab xeeb siab. Nws yog ib qho yooj yim los xyuas thiab tswj, thiab tag nrho cov energized qhov chaw nyob twj ywm kaw thiab insulated.

Lub 75 kVA tuag pem hauv ntej transformer muaj tsib - ceg tub ntxhais ua los ntawm qib siab - qib txias- dov silicon steel los xij nrog cov kauj ruam - ceg tawv pob qij txha. Nws yog tsim los ua kom tau raws li lub zog- cov qauv siv tau zoo thiab muaj 99.03% kev ua haujlwm zoo. Kev txhim kho kev sib nqus hluav taws xob thiab qis- poob aluminium windings pab txo cov khoom siv hluav taws xob. Lawv kuj txuag nyiaj dhau sijhawm thiab tiv thaiv ib puag ncig.

Lub transformer yog tsim los rau 2400/4180Y los yog 13200/22860Y grounded wye systems, ua hauj lwm stably nyob rau hauv ib txwm kev pab cuam. Nws muab kev nyab xeeb thiab muaj txiaj ntsig xa hluav taws xob hauv nroog, kev lag luam, thiab kev lag luam xa tawm, txhawb nruab nrab - thiab qis -voltage voj tshuab thoob plaws North America.

 

 

1.2 Technical Specification

75 kVA tuag pem hauv ntej transformer specification thiab cov ntaub ntawv ntawv

Xa rau
Asmeskas
Xyoo
2024
Hom
Peb theem pad mount transformer
Txuj
IEEE Std C57.12.34
Rated zog
75 kWv
Ntau zaus
60 tzs
Pub
Loop
Pem hauv ntej
Tuag
Theem
Peb
Tus naj npawb ntawm cov ceg ceg
5
Hom cua txias
ONAN
Ua kua insulating
Mineral Roj
Thawj Voltage
22.86 TSI / 13.2 kV
Secondary Voltage
0.48 y/ 0.208 kV
Vector Group
yNyj 0
Cov khoom siv winding
Aluminium
Impedance
Ntau dua lossis sib npaug li 2.7%
Kev ua tau zoo
99.03%
Coj mus rhaub Changer
NLTC
Tapping Range
±2*2.5%
Tsis Load Loss
280 W
Ntawm Load Loss
1070 W
Khoom siv
Standard Configuration

 

1.3 Cov duab kos

75 kVA tuag pem hauv ntej transformer kos duab thiab npe daim ntawv.

75 kVA dead front transformer drawing 75 kVA dead front transformer nameplate

 

 

02 Kev tsim khoom

2.1 Core

Lub 75 kVA ncoo-mounted transformer txais yuav tsib -limb core tsim los xyuas kom meej symmetrical magnetic flux paths, tsis tshua muaj suab nrov, thiab txo stray losses. Cov qauv no muab txoj hauv kev kaw rau xoom-flux nyob rau hauv Y-Y kev sib txuas, txhim kho luv luv- lub zog hluav taws xob, thiab tso cai rau lub tank zoo dua qub haum rau lub voj- pub tuag- pem hauv ntej teeb tsa feem ntau siv hauv North American tis network.

75 kva pole mounted transformer-five-limb-iron-core

 

2.2 Cua txias

75 kva pole mounted transformer-aluminum-winding

Lub HV thiab LV windings yog ua los ntawm high -conductivity aluminium conductors, kom muaj kev sib npaug ntawm kev ua haujlwm, nqi, thiab kev ua haujlwm thermal. Cov windings siv txheej txheej thiab helical winding txoj kev nrog nruj qhov ntev tolerances kom ua tau zoo heev dielectric zog thiab tsis tshua muaj to reactance. Peb cov kws tshaj lij cov kws ua haujlwm tau txais kev cob qhia los xyuas kom meej tias txhua qhov kev sib tw winding yog ib yam, kev ruaj ntseg, thiab tsis muaj deformation lossis rwb thaiv tsev puas.

 

2.3 Tank

Tag nrho cov hlau qhov chaw ntawm transformer tank thiab compartments yog huv si huv si thiab pretreated ua ntej pleev xim rau kom muaj zog adhesion thiab corrosion kuj. Rau kev tiv thaiv ntxiv -corrosion kev ua tau zoo, hauv qab 4 ntiv tes ntawm lub tank thiab cov khoom ntim yog coated nrog cov thee-tar epoxy lossis sib npaug hnyav-cov dej tiv thaiv txheej, kom ntseeg tau ntev- lub sij hawm tiv taus noo noo, av, thiab hnyav sab nraum zoov.

75 kva pole mounted-transformer-oil-tank

 

2.4 Kev sib dhos zaum kawg

75 kva pole mounted transformer-core and windings assembly
75 kva pole mounted transformer-activepart

 

Core thiab Windings Assembly
Ntxuav thiab tshuaj xyuas lub hauv paus. Nruab windings, ruaj ntseg clamps thiab rwb thaiv tsev txhawb nqa.

Transformer Tank Installation
Xyuas kom lub tank huv si thiab nqa lub transformer rau hauv qhov chaw. Teem txoj hauj lwm, kho shims thiab kev txhawb nqa, thiab clamp.

Transformer Accessories Installation
Txhim kho cov cuab yeej nqa, cov cuab yeej pab txo qis, ntsuas qib roj, cov khoom siv ntws tawm thiab cov qauv ntsuas, cov tes tuav, cov xauv, bolts, Bay-O-Net fuses, kais hloov pauv, thiab ntsuas qhov tsis raug sab hauv (IFD).

Roj Filling thiab Sealing
Lub tshuab nqus tsev- sau cov roj mus rau qib tus qauv thiab xyuas tag nrho cov ntsaws ruaj ruaj rau cov xau.

Kev sib txuas hluav taws xob thiab kev sim
Ua kom tiav siab- thiab qis-voltage kev sib txuas, txheeb xyuas qhov hloov pauv hloov pauv, thiab ua qhov ntsuas hluav taws xob, qhov hluav taws xob, hauv av, thiab kev ntsuas dej.

Sab nrauv thiab kev txheeb xyuas
Ntxuav lub tank thiab lub tshuab hluav taws xob, tshuaj xyuas cov xim thiab tiv thaiv- cov txheej txheem corrosion, thiab xyuas cov npe, cov cim ntawm lub davhlau ya nyob twg, thiab cov kab kos.
 

 

03 Kev Xeem

Kev xeem Standard

IEEE C57.12.00-2021

IEEE Standard Requirements General Requirements for Liquid-Immersed Distribution, Fais Fab, thiab Regulating Transformers

IEEE Std C57.12.34-2022

IEEE Standard Requirements for Pad-Mounted, Compartmental-Type, Self-

Txias, Peb -Phase Distribution Transformers, 10 MVA thiab me; High-Voltage, 34.5 kV Nominal System Voltage thiab hauv qab; Tsawg-V, 15 kV

Nominal System Voltage thiab hauv qab

IEEE C57.12.90-2021

IEEE Standard Test Code rau Liquid-Immersed Distribution, Fais Fab, thiab Regulating Transformer

 

Routine Test

1. Kev ntsuas ntsuas
2. Kev ntsuas qhov sib piv
3. Phase Relation Test
4. Tsis muaj Load Losses thiab Tsis Muaj Load Tam Sim No
5. Load Losses Impedance Voltage thiab efficiency
6. Applied Voltage Test
7. Induced Voltage Withstand Test
8. Kev ntsuas dej nrog lub siab rau cov kua Immersed Transformers
9. Kev ntsuas kev tiv thaiv rwb thaiv tsev
10. Roj Dielectric xeem

75 kva pole mounted transformer-ratio-tests

 

75 kva pole mounted transformer-routine-test
75 kva pole mounted transformer-factory-test

 

04 Packing thiab Shipping

4.1 Ntim

75 kVA pad-mounted transformer packing
75 kVA pad-mounted transformer foil bag


 

4.2 Shipping

Ua ntej thauj khoom, ntsuas lub transformer qhov loj thiab qhov hnyav, thiab npaj ib txoj hauv kev uas tsis txhob muaj qhov siab, qhov dav, thiab qhov hnyav. Siv cov- txaj qis lossis cov tsheb thauj khoom tshwj xeeb uas muaj peev xwm txaus.
Teem lub transformer qhov chaw ntawm lub ntiajteb txawj nqus nrog lub tsheb. Siv cov hlau channel thiab cov txheej txheem fastening kom ruaj rau lub hauv paus rau lub tsheb, yog tias tso cai. Ruaj ntseg lub transformer nrog slings los yog chains los ntawm lub tsheb thauj cov qhov, tsis txhob fragile Cheebtsam xws li radiators thiab bushings. Xauv cov khoom sab hauv thiab kaw txhua qhov rooj.
Khaws ceev Tsawg dua lossis sib npaug li 60 km / h thiab qaij Tsawg dua lossis sib npaug li 15℃thaum thauj. Tsis txhob txav tam sim ntawd thiab muaj zog vibrations. Muab cov escorts los xyuas kev khi thiab nres tsheb thaum huab cua hnyav.
Thaum lifting, khaws cov kaum sab xis tsawg dua lossis sib npaug li 60 degree. Siv cov kab kis kab mob yog tias xav tau. Ib txwm nqa upright, thiab rau cov chav uas tsis muaj lub hau sab saum toj, siv cov pas tuav hauv qab.

75 kva pole mounted transformer-shipping

 

 

05 Site thiab Summary

75 kva pole mounted transformer-front-view

Qhov no75 kVA peb-phase ncoo-mounted transformerlos ntawm Scotech tau xa mus rau Tebchaws Meskas hauv xyoo 2024. Nws muaj kev ua haujlwm siab, kev ua haujlwm zoo, thiab kev tsim qauv ruaj khov. Cov tub ntxhais thiab aluminium windings txo lub zog poob. Kev nyab xeeb, compact tsim ua rau installation thiab txij nkawm yooj yim. Nws ua haujlwm zoo rau kev faib hluav taws xob hauv nroog thiab kev lag luam thiab muab sijhawm ntev - tus nqi thiab kev pabcuam txhim khu kev qha.

 

Cim npe nrov: tuag pem hauv ntej transformer, chaw tsim tshuaj paus, tsum, nqe, nqi

Xa kev nug