Nkag siab txog Transformer Core Structure
Dec 16, 2025
Tso lus

Raws li cov cuab yeej tseem ceeb rau kev xa hluav taws xob thiab kev hloov hluav taws xob hauv cov tshuab hluav taws xob, kev ua haujlwm ntawm cov tshuab hluav taws xob ncaj qha cuam tshuam rau kev ua haujlwm ruaj khov thiab lub zog xa hluav taws xob ntawm cov hluav taws xob sib txuas. Kev ua tau zoo ntawm lub transformer feem ntau txiav txim siab los ntawm kev xaiv ntawm nws cov ntaub ntawv tseem ceeb thiab cov qauv tsim.
Los ntawm kev sib nqus hluav taws xob hloov hluav taws xob ntawm lub tshuab hluav taws xob sib nqus mus rau lub zog xa hluav taws xob ntawm lub voj voog, los ntawm kev ruaj ntseg lav ntawm lub rwb thaiv tsev rau kev ruaj ntseg ntawm cov khoom siv, kev siv ntawm txhua yam khoom siv thiab kev tsim ntawm txhua tus qauv xav tau cov haujlwm tshwj xeeb. Kab lus no systematically txheeb tawm cov ntaub ntawv tseem ceeb thiab cov yam ntxwv ntawm transformer lub ntsiab lub cev, pab kom nkag siab tag nrho cov khoom siv fais fab tseem ceeb no.
I. Cov ntaub ntawv tseem ceeb ntawm Transformer Lub Cev Lub Cev Loj: Kev xaiv meej coj los ntawm kev ua haujlwm
Kev xaiv cov khoom ntawm transformers ua raws li cov hauv paus ntsiab lus ntawm "kev ua haujlwm hloov pauv, qhov tseem ceeb ntawm kev ua haujlwm, thiab kev lag luam rationality". Cov khoom siv rau qhov sib txawv yuav tsum tau ua kom tau raws li ntau yam - qhov yuav tsum tau muaj xws li magnetic permeability, hluav taws xob conductivity, rwb thaiv tsev lub zog, thiab txhua yam muaj zog. Ntawm lawv, cov ntaub ntawv tseem ceeb tuaj yeem muab faib ua plaub pawg: cov khoom siv hluav taws xob sib nqus, cov khoom siv hluav taws xob, cov ntaub ntawv insulating, thiab cov khoom siv. Ntau yam ntaub ntawv ua hauj lwm ua ke los xyuas kom meej lub efficiency thiab ruaj khov ntawm transformers.
(I) Cov khoom siv hlau nplaum sib nqus: Cov Khoom Siv Hluav Taws Xob rau kev sib nqus zog hloov pauv
Lub magnetic Circuit Court yog txoj hauv kev tseem ceeb rau transformers kom paub txog electromagnetic induction. Nws lub luag haujlwm tseem ceeb yog coj thiab mloog zoo rau qhov chaw sib nqus thiab txo qis zog sib nqus. Yog li ntawd, cov khoom siv sib nqus hlau nplaum yuav tsum muaj cov yam ntxwv xws li siab sib nqus permeability, tsis muaj hlau tsis zoo, thiab zoo sib nqus ruaj khov. Tam sim no, cov khoom siv hluav taws xob sib nqus feem ntau siv hauv kev hloov pauv yog silicon steel nplooj ntawv thiab amorphous alloy cores.
Silicon steel los xij, tseem hu ua hluav taws xob steel ntawv, yog cov ntaub ntawv tseem ceeb rau transformer magnetic circuits. Los ntawm kev ntxiv silicon rau cov hlau ntshiab, qhov kev tiv thaiv ntawm cov khoom siv tau zoo tuaj, eddy tam sim no poob yog txo, thiab cov hlau nplaum permeability yog ho txhim khu kev qha, enabling ntau npaum kis tau tus mob ntawm magnetic teb zog. Raws li cov txheej txheem dov, silicon steel los xij tuaj yeem muab faib ua kub- dov thiab txias- dov hom. Ntawm lawv, cov ntawv txias-cov ntawv silicon steel ntawv muaj cov khoom sib nqus zoo dua vim lawv cov kev coj ua zoo dua qub, thiab tau siv dav hauv cov tshuab hloov pauv niaj hnub no. Silicon steel sheets feem ntau yog ua tiav rau hauv cov ntawv nyias (nrog thicknesses ntawm 0.35mm lossis 0.5mm) thiab coated nrog ib txheej insulating rau saum npoo kom txo qis interlaminar eddy tam sim no poob. Thaum siv, ntau daim ntawv yog stacked los ua ib tug tub ntxhais, tsim ib tug kaw magnetic Circuit Court.


Los ntawm qhov kev xav ntawm cov yam ntxwv tseem ceeb, muaj qhov sib txawv ntawm cov ntawv silicon steel thiab amorphous alloy cores. Qhov kev sib piv tshwj xeeb yog tshwm sim hauv cov hauv qab no:
|
Sib piv Dimension |
Silicon Steel Sheets |
Amorphous Alloy Cores |
|
Hlau Loss Performance |
Cov qib siab dua, cov qib ib txwm muaj siab dua tsis muaj -load poob |
Tsawg heev, tsuas yog 1/3 mus rau 1/5 ntawm silicon steel los xij, lub zog zoo heev -txuag nyhuv thaum tsis muaj -load |
|
Sib nqus Permeability |
Siab, haum rau nruab nrab thiab siab zaus magnetic teb |
Siab dua ntawm qhov tsawg zaus thiab tsis muaj zog magnetic teb, sai dua magnetic teb teb |
|
Kev ua & Mechanical Properties |
Zoo ductility, yooj yim rau txiav, xuas nrig ntaus thiab pawg, yoog rau cov txheej txheem nyuaj |
Siab brittleness, yooj yim rau tawg thaum lub sij hawm ua, yuav tsum tau tshwj xeeb tej khoom thiab lamination txheej txheem |
|
Nqi & Economy |
Mature technology, muaj peev xwm ntau lawm, ruaj khov thiab tus nqi qis |
Cov txheej txheem kev npaj ua haujlwm nyuaj, cov khoom siv siab yuav tsum tau ua, cov khoom siv tau zoo heev |
|
Daim ntawv thov Scenario |
Haum rau transformers ntawm tag nrho cov hwj chim theem, tshwj xeeb tshaj yog loj fais fab transformers thiab scenarios rhiab heev rau tus nqi thiab ua complexity |
Tsim nyog rau kev faib khoom transformers, tshiab zog txhawb transformers thiab lwm yam teb nrog nruj zog efficiency yuav tsum tau |
Amorphous alloy cores yog ib yam tshiab ntawm cov khoom siv hluav taws xob sib nqus tsim nyob rau xyoo tas los no. Lawv tau npaj los ntawm kev siv thev naus laus zis sai sai, thiab lawv qhov kev npaj atomic nthuav tawm cov qauv amorphous tsis zoo. Cov yam ntxwv no yog qhov laj thawj tseem ceeb vim li cas lawv cov hlau poob qis dua li ntawm silicon steel los xij. Ntxiv rau qhov tsis tshua muaj hlau tsis tshua muaj, amorphous alloy cores kuj muaj qhov zoo xws li cov hlau nplaum permeability siab thiab zoo corrosion kuj, ua rau lawv tsim nyog rau cov xwm txheej uas muaj zog heev. Txawm li cas los xij, cov ntaub ntawv amorphous alloy kuj muaj teeb meem xws li brittleness siab, ua haujlwm nyuaj, thiab tus nqi siab, uas txwv lawv qhov loj - nplai daim ntawv thov hauv qee qhov chaw. Nrog rau kev nce qib ntawm kev siv thev naus laus zis, kev tsim muaj peev xwm ntawm amorphous alloy cores tau maj mam txhim kho, thiab lawv daim ntawv thov kev faib ua feem nyob rau hauv lub tshav pob ntawm transformers yog tas li nthuav.
(II) Cov khoom siv hauv Circuit Court: Cov khoom siv tau zoo rau kev xa hluav taws xob
Lub Circuit Court yog channel rau transformers kom paub lub hwj chim input, conversion thiab tso zis. Nws cov ntsiab lus tseem ceeb yog qhov tsis muaj zog thiab kev ua haujlwm siab kom txo tau lub zog poob thaum lub sij hawm kis tau tus mob. Cov khoom tseem ceeb ntawm cov khoom siv rau transformer circuits yog tooj liab thiab txhuas. Txhua yam ntawm ob cov ntaub ntawv muaj nws qhov zoo thiab qhov tsis zoo, thiab kev xaiv tsim nyog yuav tsum tau ua raws li cov yam ntxwv xws li qib fais fab, daim ntawv thov scenario, thiab cov nqi siv nyiaj ntawm lub transformer.
Copper conductors yog dav siv nyob rau hauv transformer circuits vim lawv zoo heev hluav taws xob conductivity (thib ob rau nyiaj, nrog ib tug conductivity ntawm 58 × 10⁶ S / m ntawm 20 degree), zoo mechanical zog, thiab corrosion kuj. Tooj liab muaj tsawg resistivity. Nyob rau hauv tib lub load tam sim no, tooj liab conductors muaj me me poob thiab tsawg tshav kub tiam, uas yuav ua tau zoo txhim khu kev qha kev khiav hauj lwm efficiency thiab kev cia siab ntawm transformers. Nyob rau tib lub sijhawm, tooj liab muaj qhov zoo ductility thiab yooj yim rau kev ua cov xov hlau thiab windings ntawm ntau yam specifications, yoog raws tus qauv ntawm transformers nrog cov qauv sib txawv. Nyob rau hauv cov nqe lus ntawm cov yam ntxwv kev sib piv, tooj liab yog superior rau txhuas nyob rau hauv cov nqe lus ntawm conductivity efficiency, mechanical stability, thiab kev laus kuj, tab sis qhov tsis txaus ntawm cov khoom siv tooj liab ua rau nws tus nqi siab, uas yuav ua rau muaj txiaj ntsig zoo rau cov khoom tsim khoom hauv cov transformers loj lossis cov xwm txheej rhiab rau tus nqi.
Aluminium conductors muaj cov txiaj ntsig zoo ntawm cov nqi qis thiab cov peev txheej ntau. Lawv cov nqi tsuas yog kwv yees li 1/3 ntawm cov tooj liab, uas tuaj yeem txo cov nqi tsim khoom ntawm transformers. Qhov no kuj yog ib qho tseem ceeb rau lawv daim ntawv thov nyob rau hauv lub tshav pob ntawm nruab nrab thiab tsawg voltage transformers. Txawm hais tias cov conductivity ntawm txhuas yog qis dua cov tooj liab (nrog rau cov conductivity ntawm 37 × 10⁶ S / m ntawm 20 degree, tsuas yog li 64% ntawm tooj liab), qhov deficiency nyob rau hauv conductivity yuav raug them los ntawm kev nce tus ntoo khaub lig-sectional cheeb tsam ntawm tus neeg xyuas pib (feem ntau yog 1.6 npaug ntawm lub rooj sib tham ntawm cov khoom siv tooj liab). Txawm li cas los xij, aluminium conductors muaj qhov tsis txaus ntseeg: tsis tshua muaj zog txhua yam, tsuas yog ib nrab ntawm lub zog tensile ntawm tooj liab; Qhov saum npoo yog qhov yooj yim rau oxidation los ua ib qho siab - ua haujlwm oxide zaj duab xis, cuam tshuam rau kev ruaj ntseg; thiab electrochemical corrosion yog nquag tshwm sim thaum txuas nrog lwm yam hlau xws li tooj liab, ua rau kev sib cuag tsis zoo. Yog li ntawd, cov txheej txheem tshwj xeeb yuav tsum tau txais thaum lub sijhawm ua thiab kev teeb tsa, xws li siv tooj liab-aluminium hloov pauv cov pob qij txha thiab ua haujlwm los tiv thaiv- kev kho corrosion ntawm qhov txuas. Nyob rau hauv xyoo tas los no, nrog kev txhim kho ntawm aluminium alloy khoom siv technology, siab - lub zog aluminium alloy conductors ua los ntawm kev ntxiv magnesium, silicon thiab lwm yam khoom rau txhuas tau zoo heev txhim kho lawv cov neeg kho tshuab lub zog thiab corrosion kuj, kov yeej qhov tsis xws ntawm cov ntshiab aluminium conductors mus rau ib qho twg, thiab lawv daim ntawv thov ntau yog maj mam nthuav.


Cov ncauj lus kom ntxaws kev sib piv ntawm tooj liab thiab txhuas conductors yog qhia nyob rau hauv cov lus hauv qab no:
|
Performance Indicator |
Copper conductors |
Aluminium Conductors |
|
Hluav taws xob conductivity (20 degree) |
Siab (58 × 10⁶ S / m), IACS 100% |
Nruab nrab (37 × 10⁶ S / m), IACS ~ 64% |
|
Kev kub siab (20 degree) |
Tsawg (1.68 × 10⁻⁸ Ω·m) |
Siab (2.82 × 10⁻⁸ Ω·m) |
|
Mechanical Strength |
Siab tensile zog, zoo qaug zog kuj |
Tsawg, yooj yim deform nyob rau hauv kev ntxhov siab |
|
Corrosion Resistance |
Zoo, tsis yooj yim rau oxidize |
Tsis zoo, nto oxide zaj duab xis cuam tshuam kev ua haujlwm |
|
Processing & Installation |
Zoo ductility, yooj yim rau txheej txheem thiab txuas |
Yuav tsum muaj cov txheej txheem tshwj xeeb (piv txwv li, kev hloov cov pob qij txha) |
|
Nqi |
Siab, tsis tshua muaj peev txheej |
Tsawg, nplua nuj |
|
Daim ntawv thov Scenario |
High -faiv fab transformers, siab - yuav tsum tau ua haujlwm zoo |
Nruab nrab thiab qis voltage transformers, nqi -sensitive tej yaam num |
(III) Cov Khoom Siv Hluav Taws Xob: Cov Teeb Meem Tseem Ceeb rau Kev Ua Haujlwm Zoo
Thaum lub sijhawm ua haujlwm ntawm transformers, muaj qhov sib txawv ntawm qhov sib txawv ntawm lub voj voog thiab cov khoom sib nqus, thiab ntawm cov khoom siv hluav taws xob thiab cov khoom siv. Kev ua haujlwm ntawm cov ntaub ntawv insulating yog cais cov kev sib txawv no, tiv thaiv kev ua txhaum xws li xau thiab luv luv, thiab xyuas kom muaj kev nyab xeeb thiab ruaj khov ntawm cov khoom siv. Cov ntaub ntawv rwb thaiv tsev yuav tsum muaj kev ua haujlwm zoo rwb thaiv tsev, kub tsis kam, tiv thaiv kev laus, thiab lub zog txhua yam. Raws li daim ntawv thov qhov chaw thiab kev ua haujlwm, lawv tuaj yeem muab faib ua peb pawg: cov khoom siv insulating, cov ntaub ntawv ua kua insulating, thiab cov khoom siv roj insulating.
Khoom siv insulatingyog cov tub ntxhais ntawm lub tshuab hluav taws xob rwb thaiv tsev, uas muaj qhov ruaj khov thiab ntev - kev ua haujlwm rwb thaiv tsev ntev. Lawv feem ntau suav nrog cov ntawv insulating, insulating cardboard, insulating cov kua roj vanish, epoxy iav daim ntaub board, spacers, lub kaum sab xis, thiab lwm yam. Insulating ntawv thiab insulating cardboard yog cov yooj yim cov ntaub ntawv insulating, uas yuav muab faib ua fiber ntau (xws li ntoo pulp) thiab hluavtaws fiber (xws li aramid fiber) raws li raw cov ntaub ntawv. Cog fiber ntau insulating ntawv muaj tus nqi qis thiab kev ua haujlwm zoo ntawm cov roj, thiab tuaj yeem tsim cov txheej txheem rwb thaiv tsev nrog cov roj insulating. Nws feem ntau yog siv rau inter-tig thiab inter- txheej rwb thaiv tsev ntawm windings thiab kev sib cais ntawm cores thiab windings; hluavtaws fiber ntau insulating ntawv (xws li Nomex ntawv) muaj qhov zoo ntawm qhov kub thiab txias tsis kam (ntev-lub sijhawm ua haujlwm kub txog 180 degree), kev laus ua haujlwm, thiab lub zog txhua yam, thiab tsim nyog rau qhov tseem ceeb ntawm rwb thaiv tsev ntawm qhuav -hom transformers lossis roj-immersed transformers nyob rau hauv siab - qhov kub thiab txias. Insulating varnish muab faib ua roj-raws li insulating kua roj vanish thiab resin insulating kua roj vanish. Roj-raws li cov kua roj vanish muaj tus nqi qis tab sis tsis zoo kub tsis kam, thiab feem ntau yog siv rau me me thiab qis-voltage transformers; resin kua roj vanish (xws li epoxy resin kua roj vanish, polyurethane kua roj vanish) muaj siab kub kuj thiab rwb thaiv tsev lub zog. Los ntawm impregnating lub windings, nws tuaj yeem sau qhov khoob ntawm cov windings thiab qhwv cov xov hlau los tsim cov txheej txheem rwb thaiv tsev txuas ntxiv, uas tsis tsuas yog txhim kho cov rwb thaiv tsev kev ua tau zoo tab sis kuj txhim kho kev ncaj ncees ntawm cov windings thiab tiv thaiv kev co thiab hnav. Epoxy iav ntaub board yog ua los ntawm iav ntaub impregnated nrog epoxy resin thiab kub- nias, uas muaj lub zog siab, kub tsis kam, thiab zoo heev rwb thaiv tsev zog. Nws feem ntau yog siv los ua cov txheej txheem rwb thaiv tsev xws li kev txhawb nqa, kev faib tawm, thiab lub davhlau ya nyob twg ntawm cov transformers; spacers thiab lub kaum sab xis rings feem ntau yog ua los ntawm cov duab los yog cov ntaub ntawv epoxy, uas yog siv rau sab hauv kev txhawb nqa ntawm windings thiab rwb thaiv tsev ntawm winding xaus raws li, kom ntseeg tau cov qauv ruaj khov ntawm windings thiab txaus rwb thaiv tsev nyob deb.
Cov ntaub ntawv ua kua insulating, tseem hu ua roj insulating, feem ntau yog siv hauv cov roj -immersed transformers thiab muaj peb lub luag haujlwm tseem ceeb: rwb thaiv tsev, cua txias, thiab arc extinction. Lawv tuaj yeem txhim kho lub peev xwm thiab kev pabcuam lub neej ntawm transformers. Feem ntau siv cov roj insulating feem ntau muab faib ua peb pawg: cov roj ntxhia insulating roj, cov roj hluavtaws hluavtaws, thiab cov roj zaub insulating. Mineral insulating roj yog refined los ntawm roj av, nrog rau qhov zoo xws li rwb thaiv tsev kev ua tau zoo (txog voltage mus txog 40kV los yog ntau tshaj), high heat dissipation efficiency, zoo fluidity, thiab tus nqi qis. Nws yog sib xws nrog cov khoom siv insulating thiab tuaj yeem ua tiav cov ntawv insulating los tsim cov txheej txheem rwb thaiv tsev sib xyaw. Tam sim no nws yog cov khoom siv hluav taws xob ntau tshaj plaws hauv cov roj-immersed transformers thoob ntiaj teb. Synthetic insulating roj yog cov roj insulating uas npaj los ntawm cov txheej txheem tshuaj synthesis, xws li polyalphaolefin thiab silicone roj. Nws cov yam ntxwv loj tshaj plaws yog qhov taw tes siab siab (feem ntau siab dua 300 degree), muaj zog tiv thaiv kev laus, thiab zoo qis -kub fluidity. Nws yog siv dav hauv cov xwm txheej uas yuav tsum muaj kev tiv thaiv hluav taws kub siab (xws li cov tsev siab - nce siab, cov chaw hauv av), tab sis nws tus nqi siab txwv nws qhov loj - nplai nrov. Zaub insulating roj yog ib puag ncig tus phooj ywg insulating roj refined los ntawm zaub roj xws li soybean roj thiab rapeseed roj. Nws muaj qhov zoo ntawm biodegradability zoo, siab flash point, thiab cov khoom siv txuas ntxiv dua tshiab, uas yog nyob rau hauv txoj kab nrog kev txhim kho ntawm kev tiv thaiv ib puag ncig ntsuab. Txawm li cas los xij, nws qhov kev laus tsis kam thiab qis -kub fluidity tseem yuav tsum tau txhim kho, thiab tam sim no nws tseem yog tus tsav- siv rau hauv cov khoom me me xws li cov khoom siv hluav taws xob.
Gas insulating cov ntaub ntawvmuaj cov yam ntxwv ntawm kev cuam tshuam me ntsis los ntawm ib puag ncig, tsis sib xws thaum tshav kub kub dissipation, thiab tsis muaj kev pheej hmoo to. Lawv feem ntau yog siv rau kev pab cuam rwb thaiv tsev ntawm cov pa roj-insulated transformers (GIT) thiab qhuav- hom transformers. Cov pa roj siv feem ntau suav nrog sulfur hexafluoride (SF₆), nitrogen (N₂), thiab cua qhuav. Sulfur hexafluoride yog ib qho ntawm cov khoom siv roj insulating nrog cov rwb thaiv tsev zoo tshaj plaws tam sim no. Nws lub zog tawg yog ntau tshaj peb npaug ntawm huab cua, thiab nws muaj qhov zoo tshaj plaws arc - tua kev ua tau zoo, ruaj khov khoom, thiab tsis yooj yim rau hnub nyoog. Yog li ntawd, nws yog dav siv nyob rau hauv roj-insulated transformers thiab roj-insulated switchgear. Txawm li cas los xij, sulfur hexafluoride yog lub tsev cog khoom muaj zog nrog lub ntiaj teb ua kom sov siab heev (GWP) thiab lub sijhawm khaws cia ntev hauv huab cua. Nrog rau txoj cai tiv thaiv ib puag ncig nruj zuj zus, nws daim ntawv thov yuav raug txwv ntau thiab ntau dua. Tam sim no, kev siv thev naus laus zis feem ntau yog siv los txo qis emissions. Nitrogen, raws li cov roj inert, muaj qhov zoo ntawm qhov chaw dav, tus nqi qis, kev tiv thaiv ib puag ncig, thiab tsis muaj kuab paug. Txawm hais tias nws qhov kev ua haujlwm rwb thaiv tsev qis dua li ntawm sulfur hexafluoride, nws tuaj yeem ua tau raws li qhov yuav tsum tau ua ntawm rwb thaiv tsev ntawm transformers los ntawm kev ua kom cov roj siab (feem ntau 0.3-0.5MPa). Nws feem ntau yog siv rau nitrogen- puv tiv thaiv qhuav- hom transformers thiab lwm yam roj rau roj-insulated transformers. Cov huab cua qhuav yog dehumidified cua, nrog rwb thaiv tsev ua haujlwm zoo ib yam li nitrogen thiab tus nqi qis dua. Nws yog tsuas yog siv rau rwb thaiv tsev thiab cua txias ntawm me me qhuav-hom transformers, tab sis nws cov rwb thaiv tsev kev ua tau zoo heev cuam tshuam los ntawm cov av noo, yog li cov dej cov ntsiab lus yuav tsum nruj me ntsis tswj.

Daim kab xev nplaum

Crinkled ntawv

DMD

Ntawv insulated hlau

Polyester zaj duab xis

Prepreg ntaub

Epoxy resin cam khwb cia coil

Enameled Hlau

FR3 yog '
Kev sib piv ntawm cov yam ntxwv tseem ceeb ntawm ntau yam ntaub ntawv insulating yog qhia nyob rau hauv cov lus hauv qab no:
|
Hom rwb thaiv tsev |
Cov ntaub ntawv tshwj xeeb |
Cov yam ntxwv tseem ceeb |
Daim ntawv thov Scenario |
|
Khoom rwb thaiv tsev |
Insulating ntawv (cov nroj tsuag / hluavtaws fiber), insulating kua roj vanish, epoxy iav ntaub board |
Cov duab ruaj khov, ntev - rwb thaiv tsev kav ntev, qhov sib txawv ntawm qhov kub thiab txias |
Winding rwb thaiv tsev, structural rwb thaiv tsev qhov chaw |
|
Liquid rwb thaiv tsev |
Mineral insulating roj, hluavtaws insulating roj, zaub insulating roj |
Rwb thaiv tsev + txias + arc extinction, fluidity zoo |
Roj-immersed transformers, siab- khoom siv fais fab |
|
Gas rwb thaiv tsev |
Sulfur hexafluoride (SF₆), nitrogen (N₂), cua qhuav |
Tsis muaj teeb meem to, uniform heat dissipation |
Gas-insulated transformers, qhuav-hom transformers |
(IV) Cov khoom siv thiab cov khoom siv: Cov khoom tseem ceeb rau kev txhawb nqa thiab kev tiv thaiv
Cov khoom siv thiab cov khoom siv yog cov khoom siv tseem ceeb ntawm cov khoom siv hluav taws xob uas paub txog kev txhawb nqa kev siv tshuab, kev txhim kho cov qauv, kev saib xyuas kev ua haujlwm, thiab kev tiv thaiv kev nyab xeeb. Lawv tsim thiab xaiv cov khoom siv ncaj qha cuam tshuam rau cov neeg kho tshuab kev ruaj ntseg, kev cia siab rau kev ua haujlwm, thiab kev pabcuam lub neej ntawm transformers.
Cov khoom siv hauv cov khoom siv feem ntau ua haujlwm ntawm kev txhawb nqa transformer, sib nqus Circuit Court thiab kev siv hluav taws xob, thiab insulating kua encapsulation. Cov khoom tseem ceeb muaj xws li clamps, roj tso tsheb hlau luam, radiators, roj conservators, thiab lwm yam. Clamps feem ntau yog ua los ntawm cov hlau thiab siv los kho cov tub ntxhais thiab windings, ua kom muaj kev ruaj ntseg ntawm cov hlau nplaum thiab cov qauv hauv Circuit Court thiab tiv thaiv kev vibration thiab txav ntawm lub transformer vim lub zog electromagnetic thaum ua haujlwm; cov roj tank yog cov tseem ceeb encapsulation tivthaiv ntawm cov roj-immersed transformers, welded nrog steel daim hlau, siv kom haum insulating roj thiab lub ntsiab qauv ntawm lub transformer, thiab nyob rau tib lub sij hawm plays lub luag hauj lwm ntawm sealing, tiv thaiv corrosion, thiab mechanical tiv thaiv; radiators tau muab faib ua ntau hom xws li finned thiab tubular hom, uas hloov cov cua sov tsim los ntawm lub transformer thaum lub sij hawm ua hauj lwm rau huab cua los ntawm kev ua kom sov dissipation cheeb tsam kom ua tiav cov khoom cua txias; cov roj conservator txuas nrog rau sab saum toj ntawm cov roj tank, siv los them rau qhov ntim nthuav dav thiab kev cog lus ntawm cov roj insulating vim qhov kub thiab txias, thiab tib lub sijhawm txo qhov chaw sib cuag ntawm cov roj insulating thiab huab cua kom ncua roj aging.

Tank

radiator

roj conservator
Transformer accessories txawv raws li hom transformer (qhuav-hom lossis roj-immersed) thiab feem ntau ua haujlwm saib xyuas thiab tiv thaiv kev ua haujlwm. Cov khoom siv tseem ceeb ntawm qhuav- hom transformers suav nrog cov tswj kub, kiv cua, ntsuas ntsuas, thiab lwm yam: lub ntsuas kub yog siv los saib xyuas qhov ntsuas kub ntawm windings thiab cores hauv lub sijhawm tiag tiag thiab teeb tsa lub tswb thaum kub tshaj qhov pib; lub kiv cua txuas nrog lub ntsuas kub thiab pib pib thaum qhov kub thiab txias los txhim kho cov cua sov dissipation nyhuv; lub ntsuas ntsuas transformer yog siv los ntsuas qhov voltage thiab tam sim no ntawm lub transformer thiab muab cov ntaub ntawv kev txhawb nqa rau kev ntsuas thiab kev tiv thaiv ntawm lub hwj chim system. Ntxiv rau qhov ntsuas kub, cov khoom siv ntawm cov roj-immersed transformers kuj muaj xws li roj relays, siab nyem li qub, kais hloov pauv, thiab lwm yam.: cov roj relay yog cov tseem ceeb tiv thaiv cov roj -immersed transformers. Thaum muaj teeb meem tshwm sim nyob rau hauv lub transformer los tsim cov roj los yog tus nqi ntawm cov roj insulating yog txawv txav, lub sij hawm teeb meem lub tswb ceeb toom los yog txiav tawm lub hwj chim mov; lub siab nyem valve yog siv los txiav txim siab tso tawm thaum lub siab nyob rau hauv lub tank roj nce mus rau ib qho nqi vim muaj kev txhaum los tiv thaiv cov roj tank los ntawm tawg; tus kais hloov pauv yog siv los kho tus naj npawb ntawm winding lem ntawm lub transformer kom paub qhov kev hloov ntawm cov zis voltage kom hloov mus rau qhov hloov pauv ntawm lub zog hluav taws xob hluav taws xob.

roj qhov ntsuas kub nrog kev sib cuag

cua txias kiv cua

CT

BUCHHOLZ relay

Cov cuab yeej siv siab

OLTC
II. Synergistic yam ntxwv ntawm Transformer Main Lub Cev Structure
Lub ntsiab qauv ntawm lub transformer yog cov organic ua ke ntawm ntau yam ntaub ntawv, tsim ib tug synergistic system integrating "magnetic circuit - circuit - rwb thaiv tsev - qauv". Cov tub ntxhais, raws li cov tub ntxhais ntawm cov hlau nplaum sib nqus, yog tsau rau ntawm cov roj tank (roj-immersed transformer) lossis bracket (qhuav-hom transformer) los ntawm clamps. Cov windings yog qhov txhab ntawm cov tub ntxhais kab, tsim cov tub ntxhais chav tsev ntawm electromagnetic induction; cov khoom siv insulating yog siv los cais ntawm cov windings thiab cov tub ntxhais, thiab nruab nrab ntawm cov windings thiab cov windings. Nyob rau hauv cov roj-immersed transformers, insulating roj puv qhov khoob ntawm ntau yam khoom kom ua tiav rwb thaiv tsev thiab txias tib lub sijhawm; Cov khoom siv xws li cov roj tso tsheb hlau luam thiab cov clamps muab cov cuab yeej txhawb nqa rau cov khoom tseem ceeb, thiab cov khoom siv tiag tiag -lub sijhawm saib xyuas cov khoom siv ua haujlwm thiab pib cov txheej txheem tiv thaiv thaum muaj teeb meem.
Qhov kev tsim qauv no tsis tsuas yog ua kom muaj txiaj ntsig zoo ntawm electromagnetic induction tab sis kuj ua kom muaj kev nyab xeeb ntawm kev ua haujlwm los ntawm kev rwb thaiv tsev thiab cov khoom siv tiv thaiv. Nyob rau tib lub sijhawm, nrog kev txhawb nqa ntawm cov khoom siv thiab lub luag haujlwm ntawm cov khoom siv hluav taws xob, lub neej kev pabcuam ntawm cov khoom siv txuas ntxiv. Hauv cov xwm txheej sib txawv, cov qauv ntawm lub transformer yuav raug kho raws li qhov xav tau. Piv txwv li, qhuav- hom transformers tshem tawm cov roj tank thiab cov roj insulating, txais yuav cov cua txias thiab cov khoom rwb thaiv tsev, thiab tsim nyog rau sab hauv ntawm cov tsev uas muaj kev tiv thaiv hluav taws kub; roj-immersed transformers, nrog rau lawv cov kev ua tau zoo ntawm cov cua kub dissipation, yog haum rau sab nraum zoov loj -scale fais fab kis scenarios.
III. Xaus
Kev xaiv cov khoom siv thiab cov qauv tsim ntawm transformer lub cev tseem ceeb yog lub hauv paus rau nws qhov kev ua tiav ntawm cov haujlwm tseem ceeb. Lub siab sib nqus permeability ntawm cov khoom siv hluav taws xob sib nqus, tsis tshua muaj kev tiv thaiv ntawm cov khoom siv hluav taws xob, kev sib cais muaj zog ntawm cov ntaub ntawv insulating, thiab kev txhawb nqa thiab kev tiv thaiv lub luag haujlwm ntawm cov khoom siv thiab cov khoom siv ua ke tsim cov khoom siv hluav taws xob zoo, nyab xeeb, thiab txhim khu kev qha. Nrog rau kev txhim kho txuas ntxiv ntawm cov tshuab hluav taws xob cov kev xav tau rau kev siv hluav taws xob thiab kev ntseeg tau, cov khoom siv hluav taws xob kuj tseem txhim kho lub zog ntau dua -txuag thiab ruaj khov. Piv txwv li, daim ntawv thov ntawm amorphous alloy cores thiab tshiab composite insulating cov ntaub ntawv yog maj nrov. Tus qauv tsim tau dhau los ua neeg txawj ntse. Los ntawm kev sib koom ua ke sensing thev naus laus zis thiab Internet ntawm Tej yam thev naus laus zis, kev saib xyuas meej thiab kev ua haujlwm ntse thiab kev saib xyuas ntawm kev ua haujlwm ntawm lub tshuab hluav taws xob tau paub. Kev nkag siab tob txog ntawm cov ntaub ntawv thiab cov qauv ntawm lub cev hloov pauv tseem ceeb yog qhov tseem ceeb tshaj plaws rau kev tsim, tsim khoom, kev ua haujlwm thiab kev saib xyuas, thiab kev kho dua tshiab ntawm cov cuab yeej siv, thiab tseem muab kev lav zoo rau kev ua haujlwm ruaj khov ntawm lub zog hluav taws xob.
Kuv tau ua tiav cov lus Askiv version ntawm tsab xov xwm nrog peb lub rooj sib piv. Koj puas xav kom kuv kho cov hom ntawv (xws li font, kab lus sib nrug) kom ua raws li cov lus qhia tshwj xeeb, lossis hloov cov ntsiab lus ntawm ib feem? Kuv kuj tseem tuaj yeem pab koj xa cov ntsiab lus raws li cov ntaub ntawv hauv Lo Lus formatted rau kev siv ncaj qha.