Hom Qhuav Hom Transformer

Mar 05, 2026

Tso lus

Taw qhia

 

Nrog rau kev thov loj hlob ntawm kev lag luam thiab kev lag luam hluav taws xob, qhuav- hom transformers tau siv dav hauv ntau lub zog xa hluav taws xob vim lawv txoj kev nyab xeeb, kev nyab xeeb ib puag ncig, thiab kev ua haujlwm zoo. Kev nkag siab txog ntau hom kev hloov pauv qhuav pab cov lag luam xaiv cov kev daws teeb meem zoo tshaj plaws rau lawv cov kev xav tau tshwj xeeb. Phau ntawv qhia no yuav taug kev koj los ntawm lub ntsiab hom qhuav hom transformers.

 

 

Dab tsi yog Dry Type Transformer?

 

Lub tshuab hluav taws xob qhuav yog ib qho hluav taws xob hloov hluav taws xob uas siv cua lossis epoxy resin ua qhov nruab nrab insulating, tsis muaj kev cia siab rau cov roj kom txias. Muab piv rau cov roj ib txwm siv- cov tshuab hloov pauv, cov tshuab ziab khaub ncaws qhuav muaj kev nyab xeeb dua, nyiam ib puag ncig zoo dua, thiab tshwj xeeb tshaj yog haum rau cov chaw sab hauv tsev lossis cov neeg nyob ze. Lawv yog cov tsawg-kev tu, txhim khu kev qha, thiab dav siv nyob rau hauv ntau qhov chaw uas yuav tsum tau muaj kev nyab xeeb thiab ruaj khov fais fab faib, xws li:

• Cov nroj tsuag muaj kev lag luam
• High-cov tsev siab
• Tsev kho mob thiab tsev kawm ntawv
• Metro chaw nres tsheb, tshav dav hlau, thiab lwm yam kev tsim kho pej xeem
• Cov chaw khaws ntaub ntawv thiab chaw ua si siv tshuab

image

 

 

Lub ntsiab hom ntawm qhuav hom Transformers

 

Qhuav hom transformers tuaj yeem muab faib ua hom hauv qab no raws li cov qauv winding, rwb thaiv tsev tshuab, thiab txoj kev txias:

 

1. Qhib Qhov txhab / Ventilated Qhuav Hom Transformer

Lub windings ntawm hom transformer no raug thiab txias los ntawm ntuj los yog yuam airflow. Lawv feem ntau yog siv nyob rau hauv huv si, tswj, thiab qhuav nyob rau hauv tsev ib puag ncig nrog tsawg loads.


2. Lub tshuab nqus tsev siab Encapsulated (VPE) Transformer

VPE transformers muaj windings impregnated nyob rau hauv lub tshuab nqus tsev siab thiab encapsulated nrog epoxy resin, muab zoo heev rwb thaiv tsev thiab tiv thaiv ya raws, plua plav, thiab corrosion. Lawv tsim nyog rau cov chaw tsim khoom thiab ib puag ncig uas yuav tsum muaj kev ntseeg siab thiab ua haujlwm ntev.


3. Cast Resin Dry Type Transformer (CRT)

Cam khwb cia resin transformers muaj windings tag nrho encapsulated nyob rau hauv epoxy resin, yuav tsum tau ib tug tsawg kawg nkaus tu. Lawv muab kev tiv thaiv hluav taws, tiv thaiv dej noo, thiab ua haujlwm tsis muaj suab nrov, ua rau lawv zoo tagnrho rau cov chaw uas muaj zog ruaj khov thiab kev nyab xeeb yog qhov tseem ceeb.


4. Vacuum Pressure Impregnated (VPI) Transformer

VPI transformersmuaj windings impregnated nrog cov kua roj vanish nyob rau hauv lub tshuab nqus tsev thiab siab, muab zoo heev rwb thaiv tsev. Muab piv rau cov cam khwb cia resin transformers, lawv sib dua, tus nqi ntau dua - zoo, thiab kho yooj yim dua, ua rau lawv haum rau ntau yam kev siv sab hauv tsev thiab kev lag luam.

 

image 1

5. Cast Coil Qhuav Hom Transformer
Cam khwb cia coil transformerssiv precast epoxy resin coils, muab cov qauv kev ntseeg siab thiab muaj peev xwm tiv taus lub zog luv luv -circuit force thiab mechanical stress. Lawv feem ntau yog siv rau hauv kev lag luam tshwj xeeb lossis siab -load puag ncig uas muaj zog rwb thaiv tsev siab thiab kev ntseeg siab yog qhov tseem ceeb.

 

image 2

 

 

Xaiv Cov Tswv Yim rau Qhuav Hom Transformers

 

Thaum xaiv lub tshuab hluav taws xob qhuav, nws yog ib qho tseem ceeb uas yuav tsum xav txog qhov chaw teeb tsa, qhov yuav tsum tau ua, thiab kev saib xyuas. Cov hauv qab no tseem ceeb tshwj xeeb:

 

 

Installation Ib puag ncig

Rau siab -kub, siab- av av, los yog tshwj xeeb kev lag luam ib puag ncig, VPE, cam khwb cia resin, los yog cam khwb cia coil transformers yuav tsum tau ua qhov tseem ceeb los xyuas kom meej rwb thaiv tsev kev ua tau zoo thiab kev nyab xeeb kev ua hauj lwm. Rau cov txheej txheem sab hauv tsev, qhov cua / qhib- cov tshuab hloov pauv feem ntau haum.

 
 

Load Requirements

Xaiv lub transformer nrog lub peev xwm tsim nyog raws li lub zog thiab kev ua haujlwm ntawm cov khoom siv. Rau cov khoom hnyav lossis nquag pib- nres kev ua haujlwm, transformers nrog luv luv -circuit tiv taus lub peev xwm thiab cov qauv zoo, xws li cam khwb cia coil lossis VPE qhuav hom transformers, raug pom zoo.

 
 

Kev Kho Kom Zoo

Qhib- qhov txhab lossis qhov cua hloov pauv yog tus nqi- siv tau thiab yooj yim hauv cov qauv, tab sis lawv yuav tsum tau kuaj xyuas thiab tu tsis tu ncua. Cam khwb cia resin, VPE, los yog cam khwb cia coil hom yuav tsum tau kuj tsis tshua muaj txij nkawm, ua rau lawv ntau haum rau daim ntaub ntawv uas muaj kev ntseeg siab xav tau.

 
 

Kev siv nyiaj thiab tus nqi -Kev ua tau zoo

Thaum xaiv lub tshuab ziab khaub ncaws qhuav, xav txog tag nrho cov nqi, suav nrog cov nqi khoom siv, kev teeb tsa, thiab kev ua haujlwm ntev - lub sijhawm ua haujlwm thiab tu. VPI transformers muaj qhov sib npaug zoo ntawm tus nqi thiab kev ua tau zoo, ua rau lawv tus nqi - xaiv tau zoo hauv ntau qhov xwm txheej.

 

 

 

Xaus

 

Ntau hom qhuav hom transformers yog haum rau kev siv sib txawv. Los ntawm kev xaiv txoj cai hloov pauv raws li ib puag ncig, kev thauj khoom, thiab kev saib xyuas, koj tuaj yeem ua kom muaj kev ua tau zoo tshaj plaws, txuas ntxiv kev pab cuam lub neej, thiab ua kom muaj kev nyab xeeb thiab muaj txiaj ntsig zoo.

Yog xav paub ntxiv txog hom qhuav hom transformer lossis kom tau txais kev qhia kev xaiv,hu rau SCOTECH. Peb cov kws tshaj lij yuav muab cov kev daws teeb meem kom tau raws li koj cov kev xav tau tshwj xeeb.

 