Nrog kev xav tau hluav taws xob loj zuj zus thiab kev tsim kho hauv nroog loj, qhov chaw tsawg hauv pem teb ntawm cov huab cua ib txwm muaj -insulated substations (AIS) tau dhau los ua lub hauv paus rau kev tsim kho hluav taws xob. GIS (gas-insulated substations) tau ntxim nyiam rau lawv cov qauv tsim thiab txhim khu kev qha: lawv ntim cov khoom siv hluav taws xob siab -voltage nyob rau hauv ib lub thawv hlau uas muaj SF6 insulating roj, txo qhov loj me thiab txhim kho kev ntseeg tau zoo.
GIS yog dab tsi?
Lub GIS yog ib lub chaw ua haujlwm puv nkaus. Cov cuab yeej tseem ceeb xws li cov kab hluav taws xob sib txuas, cov khoom sib txuas, thiab cov busbars yog nyob rau hauv cov khoom ntim hlau kaw.
SF6 gas ua haujlwm zoo heev li lub rwb thaiv tsev thiab nres hluav taws xob arcs. Nws yog kwv yees li 100 lub sij hawm zoo ntawm kev nres arcs dua li huab cua. Qhov no tso cai rau qhov chaw nyob tau muab tso ze ua ke, ua rau lub substation me me heev. Lub txee kaw tseem tiv thaiv cov cuab yeej los ntawm nag, plua plav, thiab cov khoom corrosive. GIS tuaj yeem ua haujlwm zoo hauv qhov chaw hnyav xws li thaj chaw ntug hiav txwv lossis thaj chaw muaj kuab paug.
GIS Txoj Cai Ua Haujlwm
Lub hauv paus ntawm GIS yog nws qhov chaw kaw uas muaj SF6 insulating roj. SF6 gas ua haujlwm ua ib qho insulator. Nws nres hluav taws xob los ntawm kev dhia ntawm qhov chaw nyob. Thaum muaj teeb meem tshwm sim, lub Circuit Court breaker nyob rau hauv GIS tua cov tam sim no. Qhov no tsim qhov siab -kub arc. Lub SF6 gas txias ceev thiab tso tawm lub arc. Nws ua kom lub cev muaj kev nyab xeeb.
GIS muaj cov sensors thiab cov cuab yeej tiv thaiv. Lawv xyuas cov roj siab, qhov kub thiab txias, thiab lwm yam cim tseem ceeb txhua lub sijhawm. Yog hais tias ib yam dab tsi mus tsis ncaj ncees lawm, lub tswb ceeb toom cov neeg ua haujlwm. Qhov no pab kom lub kaw lus ua haujlwm ruaj ntseg.

Cov Cheebtsam
GIS feem ntau muaj cov hlau casing, busbars, thiab ntau yam siab -voltage switchgear.
Cov hlau casing seals thiab tiv thaiv tag nrho cov kab ke.
Busbars (ua rods) xa cov high -voltage tam sim no nyob rau hauv lub SF6 roj.
Circuit Court breakers ntawm cov kab tseem ceeb yog cov cuab yeej tiv thaiv tub ntxhais, cuam tshuam sai sai.
Disconnectors cais cov khoom siv los ntawm kab sib chaws thaum kho.
Grounding keyboards muab kev nyab xeeb hauv av thaum tu.
GIS kuj tau nruab nrogtam sim no transformers(CTs) thiab voltage transformers (VTs) los muab cov ntaub ntawv ntsuas rau kev tiv thaiv relay thiab automation systems.
Nws txuas nrog rau sab nraud fais fab tuag ntawm bushings.
Lub kaw lus soj ntsuam xyuas cov roj siab, qhov ntsuas hluav taws xob, thiab lwm yam tsis muaj nyob hauv lub sijhawm, muab lub tswb nrov thiab ua haujlwm yog tias pom muaj qhov tsis txaus ntseeg, ua kom muaj kev nyab xeeb ntawm kev ua haujlwm.
Qhov tseem ceeb ntawm GIS

Ib qho ntawm qhov zoo tshaj plaws ntawm GIS yog, yooj yim heev, nws qhov loj me. Txhua yam-txhua qhov siab- qhov hluav taws xob- yog kaw nruj rau hauv cov khoom hlau. Qhov ntawd txhais tau tias tag nrho cov teeb tsa yuav siv qhov chaw tsawg dua qhov qhib - huab cua substation. Rau cov neeg coob coob hauv nroog lossis cov chaw sab hauv tsev uas txhua qhov chaw hauv pem teb tseem ceeb, qhov ntawd yog qhov yeej tiag.
Tab sis compactness tsis yog tib yam GIS tau mus rau nws. Lub kaw lus tsim ua kom tsis txhob nag, plua plav, thiab muaj kuab paug- tej yam uas feem ntau ua rau muaj teeb meem hauv cov chaw nres tsheb ib txwm muaj. Vim li ntawd, kev rwb thaiv tsev tsis zoo yog tsawg, thiab kev txiav hluav taws xob tsis tshua muaj tshwm sim. Kev nyab xeeb tau txais kev txhawb nqa ib yam nkaus: cov neeg ua haujlwm tsis txhob kov qhov chaw nyob, yog li qhov kev pheej hmoo ntawm hluav taws xob poob qis dua.
Kev tu? Kuj ceeb tias yooj yim. Tsis zoo li AIS, uas xav tau kev tu thiab tshuaj xyuas tsis tu ncua, GIS tuaj yeem khiav tau ntau xyoo nrog yuav luag tsis muaj kev ntxhov siab. Lub Hoobkas- cov khoom tsim tau tuaj yeem npaj mus- yooj yim txuas, nrawm rau kev sim, thiab ceev kom muaj zog. Kev teeb tsa txav tau yooj yim yam tsis muaj kev hloov pauv tsis kawg ntawm qhov chaw.
Yog tias koj xav paub txog yuav ua li cas ob lub tshuab sib dhos, saib pebKev sib piv ntawm AIS thiab GIS-nws rhuav tshem lawv cov qauv, kev ua tau zoo, thiab qhov twg txhua qhov ci.
Kev Sib Tw thiab Cov Lus Teb
Txawm hais tias GIS thev naus laus zis muab cov txiaj ntsig meej, nws tseem ntsib qee qhov teeb meem tiag tiag.
Ib qho ntawm cov teeb meem tseem ceeb yog tus nqi. Vim tias nws siv cov ntaub thaiv hlau tuab thiab xav tau siab - kev tsim khoom muaj tseeb, GIS chav tsev tuaj yeem raug nqi ib nrab ntxiv ntau npaum li kev teeb tsa AIS zoo sib xws. Tus nqi siab dua no feem ntau ua rau cov neeg yuav khoom hnyav ntev - lub sij hawm cia siab rau luv luv - pob nyiaj siv.
Lwm qhov kev txhawj xeeb yog ib puag ncig ntawm tej yam. Cov roj insulating SF₆, uas ua rau GIS yog li compact thiab txhim khu kev qha, kuj muaj lub peev xwm ua kom sov lub ntiaj teb siab heev. Txawm hais tias cov txheej txheem niaj hnub no tau tsim los tiv thaiv cov dej xau, cov roj yuav tsum tau ua tib zoo saib xyuas thoob plaws hauv nws lub neej - thaum lub sijhawm teeb tsa, tu, thiab rov ua dua tshiab.
Txhawm rau hais txog qhov no, cov tuam ntxhab thiab cov khoom siv hluav taws xob tam sim no sim cov roj av "eco-tus phooj ywg" tshiab uas tuaj yeem hloov lossis txo kev siv SF₆. Qee qhov ntawm cov kev xaiv no, xws li g³ thiab lwm yam qis -GWP sib tov, cog lus tias yuav ua kom muaj hluav taws xob zoo tib yam thaum txiav kev cuam tshuam ib puag ncig ntau dua 99%. Cov kev txhim kho no qhia tau tias GIS tsis yog tshooj kaw - nws txuas ntxiv hloov mus rau kev siv tshuab huv thiab ruaj khov dua.
Cov xov xwm insulating tshiab xws li g³ thiab Novec tau siv hauv GIS, txo lawv cov peev txheej hauv tsev cog khoom thiab muab txoj hauv kev tshiab rau kev txhim kho kom ruaj khov. Lwm qhov kev sib tw yog qhov nyuaj ntawm kev saib xyuas siab: yog tias muaj kev cuam tshuam sab hauv, kev kho yuav tsum muaj cov cuab yeej tshwj xeeb thiab cov khoom siv roj rov qab, uas yuav ua rau muaj kev tu ncua ntev. Thaum kawg, vim nws cov qauv compact, GIS yog nyob ntawm qhov chaw layout, ua loj -scale expansion lossis renovation ntau complex.
Main Application Scenarios
GIS ua tau zoo hauv ntau qhov chaw txwv thiab tshwj xeeb.
Hauv thaj av- txwv tsis pub hauv nroog lossis cov tsev nyob sab hauv, GIS ua kom qhov chaw siv ntau tshaj plaws.
Nws qhov kev ruaj ntseg siab yog qhov tsim nyog rau cov chaw ua lag luam thiab cov chaw khaws ntaub ntawv, qhov twg cov khoom siv hluav taws xob muaj kev ntseeg siab yog qhov tseem ceeb.
Nyob rau hauv qhov chaw - txwv tsis pub ua liaj ua teb cua los yog cov platforms, GIS tuaj yeem ua tiav lub zog hloov pauv thiab tiv thaiv marine corrosion.
Hauv thaj chaw roob thiab qhov chaw huab cua, GIS yooj yim rau kev thauj mus los thiab teeb tsa, ua rau nws tsis tshua muaj kev cuam tshuam rau huab cua phem.
Tej yaam num nyob rau hauv hav zoov hav zoov thiab roob toj siab ib puag ncig, xws li hydropower chaw nres tsheb, muaj peev xwm nruab GIS sab hauv tsev los yog nyob rau hauv tunnels los tiv thaiv cov cuab yeej los ntawm sab nraum zoov ya raws, dej khov, thiab daus.




Kev ua haujlwm thiab kev tu
Thaum GIS ua haujlwm tau ntseeg tau thiab muaj kev saib xyuas ntev, kev tshuaj xyuas tsis tu ncua tseem yuav tsum tau ua.
Cov neeg ua haujlwm yuav tsum saib xyuas SF6 roj siab hauv lub sijhawm thiab siv cov khoom xau los txheeb xyuas qhov ua tau me me.
SF6 cov khoom siv roj rov qab thiab cov khoom siv ntxiv yuav tsum tau teeb tsa kom muaj kev nyab xeeb rov qab cov roj thaum tu.
Kev saib xyuas niaj hnub suav nrog kev tshuaj xyuas cov cuab yeej siv lub tshuab thiab cov ntsaws ruaj ruaj rau kev puas tsuaj thiab ntsuas qhov ntsuas hluav taws xob los ntawm kev ntsuas hluav taws xob xws li kev sim tawm ib nrab.
Cov kev saib xyuas no ua kom ntev - lub sijhawm ua haujlwm ruaj khov.