Thaum muas ncoo-mounted transformers, tuag pem hauv ntej thiab nyob pem hauv ntej yog ob txoj kev xaiv. Txhua qhov muab cov txiaj ntsig tshwj xeeb thiab ua kom haum rau ntau hom kev thov. Kab lus no yuav tsom mus rau qhov sib txawv tseem ceeb ntawm ob, pab koj txiav txim siab ntau dua thiab ua tau zoo.

Dab tsi yog Dead Front Pad Mounted Transformer?
Ib tug tuag pem hauv ntej ncoo mounted transformer yog tsim los nrog tag nrho cov energized Cheebtsam tag nrho cov rwb thaiv tsev thiab kaw, tiv thaiv kev sib cuag ncaj qha nrog nyob qhov chaw. Nyob rau hauv qhov tsim no, siab -voltage cables feem ntau yog txuas nrog insulated plug- nyob rau hauv connectors, xws li lub luj tshib connectors, tso cai rau installation thiab ua hauj lwm yam tsis muaj energized Cheebtsam. Qhov no ua rau muaj kev nyab xeeb zoo, tshwj xeeb tshaj yog nyob rau thaj chaw uas muaj kev nkag mus rau pej xeem.
Nyob ntawm daim ntawv thov yuav tsum tau, tuag pem hauv ntej ncoo mounted transformers feem ntau muaj nyob rau hauv cov nram qab no configurations:
• Ib Theem Ib:Haum rau kev siv hauv tsev thiab lub teeb lag luam
• Peb Theem:Zoo tagnrho rau cov chaw ua lag luam thiab kev lag luam loj
• Loop Feed:Txhawb nqa looped tis systems, txhim kho cov khoom siv hluav taws xob kev ntseeg siab, feem ntau siv hauv cov phiaj xwm hauv nroog
• Radial Feed:Cov qauv tsim yooj yim dua, feem ntau yog siv hauv ib qho - qhov chaw faib khoom nrog tus nqi qis
Dab tsi yog Live Front Pad Mounted Transformer?
Lub qhov nyob hauv pem hauv ntej mounted transformer muaj siab -voltage terminals uas feem ntau raug rau hauv lub compartment. Thaum lub hau npog qhib, cov khoom siv hluav taws xob no tuaj yeem siv ncaj qha, ua rau muaj kev pheej hmoo ntawm kev sib cuag. Vim li no, nyob pem hauv ntej transformers feem ntau xav tau kev teeb tsa thiab kev ua haujlwm los ntawm cov kws tshaj lij. Lawv cov qauv tsim yog qhov yooj yim thiab tus nqi- ua haujlwm tau zoo, ua rau lawv tsim nyog rau kev tswj hwm ib puag ncig xws li cov chaw tsim khoom, chaw nres tsheb, lossis lwm qhov chaw txwv rau cov neeg ua haujlwm tsim nyog.
Tuag Front vs Live Front: Qhov txawv tseem ceeb
Cov lus hauv qab no qhia txog qhov sib txawv tseem ceeb ntawm Tuag Pem Hauv Ntej thiab Live Front ncoo mounted transformers rau kev sib piv yooj yim.
|
Kev sib piv |
Tuag pem hauv ntej Pad Mounted Transformer |
Nyob pem hauv ntej Pad Mounted Transformer |
|
Kev nyab xeeb |
Siab: Tag Nrho Cov Khoom Siv Hluav Taws Xob, cov khoom siv hluav taws xob tsis siv tau |
Nruab Nrab: High- voltage terminals raug nthuav tawm, xav tau cov neeg ua haujlwm cob qhia |
|
Tsim & Txuas |
Insulated plug-nyob rau hauv connectors (lub luj tshib connectors) |
Exposed bolted terminals |
|
Installation & Kho |
Kev nyab xeeb rau kev khiav lag luam, kev saib xyuas tus qauv |
Yooj yim rau kev khiav lag luam, tab sis yuav tsum tau ua los ntawm cov neeg ua haujlwm raug cob qhia |
|
Nqi |
Kev nqis peev ntau dua |
Yooj yim tsim, tus nqi qis dua |
|
Tej kev siv |
Cov chaw nyob, cov tsev lag luam, tsev kawm ntawv - qhov chaw uas yuav tsum muaj kev nyab xeeb siab |
Cov chaw muaj chaw, substations, los yog tswj ib puag ncig |
Yuav Ua Li Cas Xaiv Ntawm Cov Tuag Pem Hauv Ntej thiab Nyob Hauv Pem Hauv Ntej Pad Mounted Transformers
Thaum xaiv ntawm Dead Front thiab Live Front ncoo mounted transformers, qhov kev txiav txim siab feem ntau yog nyob ntawm qhov yuav tsum tau muaj kev nyab xeeb, qhov chaw teeb tsa, thiab kev siv nyiaj txiag.
• Tuag Front feem ntau pom zoo:Nrog tag nrho cov txheej txheem insulated, Tuag Front transformers muaj kev nyab xeeb dua thiab txo qhov kev pheej hmoo ntawm hluav taws xob poob siab. Lawv yog cov kev xaiv zoo tshaj plaws rau thaj chaw nyob, cov tsev lag luam, lossis ib puag ncig uas tib neeg tuaj yeem tuaj yeem ntsib.
• Live Front apps:Rau qhov laj thawj kev nyab xeeb, Live Front transformers tam sim no tsis tshua siv nyob rau hauv pej xeem lossis cov chaw muag khoom hnyav. Txawm li cas los xij, lawv tseem tuaj yeem txiav txim siab hauv cov chaw ua haujlwm nyob deb nroog, cov chaw ua haujlwm substations, lossis cov chaw tswj hwm uas tsuas yog cov neeg ua haujlwm tau kawm ua haujlwm. Cov qauv tsim nyob pem hauv ntej yog yooj yim dua thiab raug nqi ntau dua - siv tau hauv cov xwm txheej no.

Xaus
Dead Front transformers muaj kev nyab xeeb dua thiab zoo tagnrho rau ib puag ncig nrog cov pej xeem lossis cov neeg ua haujlwm sib cuag, ua rau lawv xaiv rau feem ntau cov haujlwm. Nyob rau pem hauv ntej transformers feature ib tug yooj yim tsim thiab tus nqi qis tab sis tsuas yog tsim nyog rau kev tswj ib puag ncig ua los ntawm cov neeg ua hauj lwm kawm. Thaum xaiv ntawm ob, xav txog kev nyab xeeb, ib puag ncig kev teeb tsa, thiab kev siv nyiaj kom ntseeg tau tias lub tshuab hluav taws xob ua tau raws li qhov xav tau ntawm qhov project thaum tus nqi seem - zoo.