500 KVA IEC 60076 Distribution Transformer-22/0.415 KV|Australia 2025
Muaj peev xwm: 500 kVA
Qhov hluav taws xob: 11/0.415 kV
Nta: Tsawg-voltage txuas tooj liab busbar
Jiangshan Scotech Electrical Co., Ltd yog ib qho ntawm feem txhim khu kev qha manufacturers thiab lwm tus neeg ntawm 500 kva iec 60076 tis transformer-22/0.415 kv|Australia 2025 hauv Suav teb. Thov koj xav tias dawb mus yuav cov khoom lag luam zoo rau kev muag ntawm no thiab tau txais cov duab kos los ntawm peb lub hoobkas. Tiv tauj peb kom paub meej ntxiv.

Roj-immersed distribution transformer: roj-txias, pob zeb- khov kho - tiv thaiv txhua watt, txhua hnub.
01 General
1.1 Project Description
500 kVA IEC 60076faib transformertau xa mus rau Australia nyob rau xyoo 2025. Qhov ntsuas hluav taws xob ntawm IEC 60076 faib transformer yog 500 kVA nrog KNAN txias. Qhov siab voltage yog 22 kV nrog ± 2 * 2.5% tapping ntau (NLTC), qhov tsawg voltage yog 0.415 kV, lawv tsim ib tugpawg vectorntawm yN0.
Qhov no 500kVA, peb -theem, hermetically kaw tis transformer yog tsim los rau hnyav sab nraum zoov ib puag ncig, nws ua raws li IEC 60076 thiab AS/NZS cov qauv, muab kev ua haujlwm siab (Ntau dua lossis sib npaug rau 99.16%) thiab txhim khu kev lag luam nyob rau hauv huab cua txias (txog 50℃ambient).
Cov Ntsiab Lus Tseem Ceeb
- FR3 kua dej:Biodegradable, siab - hluav taws kub- taw tes ( Ntau dua lossis sib npaug li 300℃) ntuj ester, txhim kho hluav taws kev nyab xeeb thiab rwb thaiv tsev lub neej.
- HV Cable Box:IP56- ntsuas, kaw tag nrho, nrog rau hauv qab nkag thiab lub luj tshib plug-in txiav rau kev nyab xeeb, huab cua tiv thaiv kev sib txuas.
- LV Cable Box nrog Extended Copper Busbars:IP56-rated enclosure nrog rau txuas tooj liab busbars thiab kev txhawb nqa kom yooj yim, hloov tau LV cable txiav.
- Terminal Box nrog Anti-Condensation rhaub:IP56 davhlau ya nyob twg lub thawv haum nrog 230V AC qhov chaw tso cua sov kom tiv thaiv kom tsis txhob ya raws thiab ua kom ntev - lub sij hawm tswj Circuit Court ncaj ncees.
- Secondary (Control) Contacts:Muab WTI (110℃tswb / 130℃mus txawv tebchaws), roj kub, siab nyem, thiab qis roj qib tswb - tag nrho nrog 230V AC hu rau SCADA kev koom ua ke.
Lub tshuab hluav taws xob no sib txuas cov kev sib khi ruaj khov, eco- cov kua dej FR3 tus phooj ywg, thiab muaj kev tiv thaiv IP56, xa cov hluav taws xob muaj kev nyab xeeb thiab muaj kev ntseeg siab nyob rau hauv qhov chaw xav tau.
1.2 Technical Specification
500 kVA IEC 60076 Kev faib tawm transformer specifications hom thiab cov ntaub ntawv ntawv
|
Xa rau
Teb chaws USA
|
|
Xyoo
2025
|
|
Hom
Pad mounted transformer
|
|
Txuj
IEC60076
|
|
Rated zog
500 kVA ua
|
|
Ntau zaus
50 HZ
|
|
Theem
3
|
|
Hom cua txias
KNAN
|
|
Thawj Voltage
22kv ua
|
|
Secondary Voltage
0.415 kV
|
|
Cov khoom siv winding
Tooj
|
|
Vector Group
yNyj 0
|
|
Impedance
5.75%±7.5%
|
|
Kev ua tau zoo
Ntau dua lossis sib npaug li 99.16%
|
|
Coj mus rhaub Changer
NLTC
|
|
Tapping Range
±2*2.5%
|
|
Tsis Load Loss
Tsawg dua lossis sib npaug li 0.95 kW
|
|
Ntawm Load Loss
Tsawg dua lossis sib npaug li 5.8 kW
|
1.3 Cov duab kos
500 kVA IEC 60076 Kev faib tawm transformer daim duab kos duab thiab loj.
![]() |
![]() |
02 Kev tsim khoom
2.1 Core

Cov tub ntxhais transformer yog ua los ntawm txias-rolled grain-oriented silicon steel nrog ib kauj ruam ncej. Kev tsim hluav taws xob sib nqus tau ua tiav thiab ua tau raws li qhov project yuav tsum tau ua kom poob qis thiab siab permeability. Kev tsim thiab kev tsim khoom ua raws li IEC 60076. Kev ntsuas tsis muaj kev thauj khoom tsuas yog 0.785 kW (yuav tsum Tsawg dua lossis sib npaug li 0.95 kW), thiab tsis muaj qhov thauj khoom tam sim no yog 0.68% (yuav tsum Tsawg dua lossis sib npaug li 1.2%). Ob qhov ntsuas tseem ceeb yog qhov zoo dua li cov kev txwv ib txwm, ua pov thawj zoo heev ntawm kev tswj tsis tau. Rau kev ruaj ntseg zoo, core stacking siv cov cuab yeej ua haujlwm siab, txhua qhov sib koom ua ke yog tswj hwm nruj, thiab kev ua haujlwm sib nqus tau raug kuaj. Kev tsim cov ntsiab lus tseem ceeb: cov kauj ruam kauj ruam sib koom ua ke, tsis tshua muaj silicon steel, kev soj ntsuam kev ua haujlwm sib nqus tag nrho.
2.2 Cua txias
Lub winding siv electrolytic tooj liab nrog purity Ntau dua los yog sib npaug rau 99.9% thiab precision winding txheej txheem, ua tau raws li qhov project tus conductivity thiab thermal yuav tsum, thiab ua raws li IEC 60076 tus qauv rau kev tiv thaiv thiab kub nce. Ntsuas HV winding kub nce yog 58.69 K (yuav tsum Tsawg dua los yog sib npaug rau 60 K), LV winding kub nce yog 57.84 K (yuav tsum Tsawg dua los yog sib npaug rau 60 K), thiab qhov siab tshaj qhov tsis sib npaug tsuas yog 0.41%. Cov duab no qhia tau hais tias cov qauv winding tsis sib xws thiab zoo heev tshav kub dissipation. Kev ruaj ntseg zoo suav nrog cov tshuab winding tsis siv neeg nrog kev saib xyuas lub sijhawm tiag tiag thiab ntau txheej rwb thaiv tsev. Kev tsim khoom tseem ceeb: high-purity tooj liab conductors, tsis siv neeg winding + real-time kuj saib xyuas, multi-layer rwb thaiv tsev rau lub neej ntev.

2.3 Tank

Covtankis a fully sealed corrugated steel structure with IP56 protection, no conservator and no nitrogen cushion, fully suitable for harsh outdoor environments, and designed according to IEC 60076 sealing and protection standards. Kev ntsuas cov pa xau ntawm 15 kPa rau 24 teev tsis pom qhov xau, thiab qhov ntsuas hluav taws xob siv hluav taws xob (HV sab 50 kV / 60 s) dhau yam tsis muaj teeb meem, lees paub qhov kev sib khi ruaj khov thiab muaj peev xwm tiv taus. Kev ruaj ntseg zoo: 100% tshuaj xyuas tag nrho cov welds, ua tiav kev ntsuas kev sib khi. Kev tsim cov ntsiab lus tseem ceeb: tag nrho ntim corrugated tsim, IP56 qib tiv thaiv qib siab, RAL7035 corrosion-resistant txheej.
2.4 Kev sib dhos zaum kawg
Lub rooj sib txoos zaum kawg ua ke nrog ntau yam tseem ceeb: FR3 ntuj ester roj (siab kub taw tes, biodegradable, environmentally friendly thiab nyab xeeb); HV sab nrog kaw IP56 HV cable box, hauv qab nkag, luj tshib plug-in connectors; LV sab nrog LV cable lub thawv ntxiv rau cov kab tooj liab txuas ntxiv thiab kev txhawb nqa rau kev xa xov yooj yim; terminal box nrog built-in anti-condensation qhov chaw rhaub (230V / 50W) los tiv thaiv ya raws; Ua tiav cov kab txuas txuas txuas ntxiv nrog rau qhov ntsuas qhov ntsuas kub ntawm qhov ntsuas, ntsuas roj kub, lub siab nyem valve, qis roj qib tswb, thiab lwm yam. Txhua yam khoom siv yog tsim raws li IEC 60076 cov qauv khoom siv. Kev ntsuas kev ntseeg tau: induced voltage withstand test ntawm 30.8 kV / 150 Hz rau 40 vib nas this - tsis muaj kev puas tsuaj; xob laim impulse kuaj ntawm 125 kV tag nrho nthwv dej - dhau. Qhov no ua pov thawj ua tiav rwb thaiv tsev system kev ncaj ncees thiab txhim khu kev qha accessory muaj nuj nqi. Kev lees paub zoo: 100% kev sim ua haujlwm ntawm tag nrho cov khoom siv ua ntej sib dhos, kev txheeb xyuas ib-rau-ib qho ntawm cov kab hluav taws xob tiv thaiv cov khoom siv tiag tiag, tag nrho simulation khiav ua ntej xa. Kev tsim cov ntsiab lus tseem ceeb: kev sib xyaw HV / LV cable thawv, tiv thaiv condensation rhuab davhlau ya nyob twg lub thawv, pre-installed full-function thib ob thaiv kev tiv tauj.

03 Kev Xeem
Lub transformer tau dhau los ua tiav cov txheej txheem niaj hnub thiab hom kev xeem, nruj me ntsis raws li IEC 60076-1/2/3/10, nrog rau tag nrho cov khoom dhau los thiab ntau qhov ntsuas tau zoo dua li qhov yuav tsum tau ua. Cov txiaj ntsig tseem ceeb: tsis muaj kev thauj khoom poob 0.785 kW (zoo dua Tsawg dua lossis sib npaug li 0.95 kW), thauj khoom poob 5.764 kW (zoo dua Tsawg dua lossis sib npaug 5.8 kW), luv-circuit impedance 5.90% (nyob rau hauv kam rau ua), HV 4 winding kub 9.6 ℃ siab (zoo dua Less tshaj lossis sib npaug li 60 K thiab Tsawg dua lossis sib npaug li 55 K raws), qhov ntsuas dej xau 24h - tsis xau, xob laim puv nthwv dej impulse 125 kV - dhau, thov voltage 50 kV / 60 s - dhau, suab siab theem tsuas yog 47.3 dB (A) (5 deb tshaj li A Less) Kev ruaj ntseg zoo: tag nrho cov cuab yeej ntsuas ntsuas tsis tu ncua, cov neeg ua haujlwm xeem ntawv pov thawj, peb-theem tshuaj xyuas cov ntawv xeem. Manufacturing highlights: tag nrho-txheej txheem xeem kev pab them nqi, traceable cov ntaub ntawv, ua raws li thoob ntiaj teb cov qauv.


04 Packing thiab Shipping
4.1 Ntim

Lub transformer yog ntim rau hauv lub siab-lub zog shockproof ntoo rooj plaub los yog steel ncej. Sab nraud qhov ntev yog tswj tsis pub dhau 2000 × 1400 × 1800 mm, tag nrho qhov hnyav tsis tshaj 3200 kg, ntsib qhov chaw thiab thauj khoom rau ntau lub thawv thiab thauj khoom loj. Kev ntim khoom tsim ua raws li cov qauv xa tawm thoob ntiaj teb (xws li ISPM 15 cov kev cai kho cua sov). Ua ntej packing, tag nrho chav tsev yog noo-kho. Lub transformer muaj kev ruaj ntseg nyob rau hauv rooj plaub nrog multi-point fastening thiab cushioning cov ntaub ntawv los tiv thaiv kev thauj mus los kev puas tsuaj. Ib qho kev xaiv qhov taw qhia kev poob siab tuaj yeem ntsia tau los saib xyuas cov kev cuam tshuam thaum caij tsheb npav. Kev ruaj ntseg zoo: qhov kawg ntawm kev pom thiab ua haujlwm ua ntej packing, kev saib xyuas tag nrho thiab cov ntaub ntawv yees duab ntawm cov txheej txheem thauj khoom. Kev tsim cov ntsiab lus tseem ceeb: lub zog loj export-qib ntim cov ntaub ntawv, ua ke cov dej noo thiab kev tiv thaiv kev poob siab, qhov taw qhia kev poob siab.
4.2 Shipping
Kev xa khoom yog los ntawm hiav txwv mus rau Fremantle Chaw nres nkoj, Australia, raws li CIF cov lus, nrog rau hnub xa khoom ntawm lub Peb Hlis 15, 2026. Ib qho kev xaiv tau tsim nyob rau hauv kev saib xyuas kev thauj mus los tuaj yeem sau lub sijhawm kub, av noo, poob siab, thiab cov ntaub ntawv qhov chaw, kom ntseeg tau tag nrho traceability. Cov txheej txheem thauj khoom ua raws li IEC 60076 cov cai rau kev thauj mus los. Ua ntej xa tawm, lub transformer tau ua tiav tag nrho cov kev ntsuam xyuas thiab tag nrho cov khoom txav tau raug kaw. Kev ntseeg tau: kev thauj mus los kev vibration tsom xam yog siv los txhim kho cov txheej txheem kho, thiab kev kuaj xyuas kev thauj mus los tau ua tiav ua ntej xa khoom xa tuaj. Kev tuav pov hwm zoo suav nrog kev xaiv cov chaw muab kev thauj mus los uas muaj kev paub txog kev thauj khoom siv hluav taws xob, kev kos npe zaum kawg los ntawm tus neeg soj ntsuam zoo ua ntej xa khoom, thiab kev pov hwm kev thauj mus los. Kev tsim cov ntsiab lus tseem ceeb: kev xaiv lub sijhawm thauj mus los ntawm lub sijhawm saib xyuas qhov system, tag nrho cov logistics tuaj yeem ua tiav, nruj ua raws li hnub xa khoom.

05 Cov ntsiab lus
Hauv cov ntsiab lus, qhov no 500 kVA / 22 kV / 0.415 kV roj-immersed tis transformer ua tau zoo heev hauv cov tub ntxhais, winding, tank, kawg sib dhos, kuaj, ntim thiab xa khoom. Kev ntsuas cov ntaub ntawv qhia tias tsis muaj load poob 0.785 kW, load poob 5.764 kW, HV winding kub nce 58.69 K, cov roj saum toj kawg nkaus kub nce 49.53 K, luv-circuit impedance 5.90%, kev ntsuam xyuas 24h tsis to, xob laim impulse 125 kV suab dhau voltage 0. 47.3 dB(A) - tag nrho cov ntsuas tau dhau los thiab ntau qhov zoo dua li qhov yuav tsum tau ua. Cov txheej txheem tsim khoom nrog kev tswj hwm nruj thiab kev sim ua tiav kom ntseeg tau cov khoom sib xws thiab kev ntseeg siab. Cov ntsiab lus tseem ceeb muaj xws li: qis-tsawg stepped-lap core, high-purity tooj liab windings, tag nrho ntim IP56 corrugated tank, FR3 ib puag ncig tus phooj ywg siab-hluav taws-point roj, HV cable box, LV cable box nrog txuas tooj liab tuav, anti-condensation davhlau ya nyob twg lub thawv, thiab ua kom tiav cov kev sib txuas txuas txuas ntxiv. Qhov no transformer yog haum rau qhov hnyav sab nraum zoov ib puag ncig, ua tau raws li qhov xav tau ntawm kev ua haujlwm siab, kev saib xyuas qis, thiab kev nyab xeeb siab.

Cim npe nrov: IEC 60076 transformer, chaw tsim tshuaj paus, tsum, nqe, nqi
You Might Also Like
2000 kVA Fais Fab Fais Fais Fais Distribution Transf...
2250 kVA Pad Mounted Transformer-12.47/0.6 kV|USA ...
75 kVA 3 Phase Distribution Transformer-0.22/0.415 k...
2000 KVA Distribution Transformer-11/0.433 KV|Malays...
750 KVA Fais Fais Fais Fais Distribution Transformer...
500 KVA Distribution Transformer-11/0.415 KV|Austral...
Xa kev nug