2000 KVA Distribution Transformer-11/0.433 KV|Malaysia 2024

2000 KVA Distribution Transformer-11/0.433 KV|Malaysia 2024

Lub Tebchaws: Malaysia 2024
Peev xwm: 2000kVA
Qhov hluav taws xob: 2000kVA 11/0.433kV
Feature: LV sab nrog 4 tooj liab busbars rau 16 × 630 mm² cables
Xa kev nug

 

2000 kVA distribution transformer

2000 kVA transformer rau qhov ruaj khov thiab ua haujlwm tau zoo hauv cov roj regenerated ua cov nroj tsuag

 

 

01 General

1.1 Project Description

Qhov no transformer yog xa mus rau America nyob rau hauv 2024 thiab tsim raws li tus txheej txheem thoob ntiaj teb IEC 60076-1:2011. Nws yog 2 MVA kua-immersed transformer nrog high / low voltage ntsuam xyuas ntawm 11 kV / 0.433 kV thiab ib pab pawg Dyn11 vector, kom ntseeg tau tias muaj kev lag luam hluav taws xob faib hluav taws xob thiab kev ua haujlwm zoo ntawm theem siab thiab qis voltage sab.

Qhov no transformer yog tsim los rau ib tug regenerated roj ua cov nroj tsuag, tuav pov tseg roj. Nws muab lub zog ruaj khov thiab txhim khu kev qha rau cov khoom siv txuas ntxiv xws li twj tso kua mis, cua sov, thiab compressors. Nrog 2 MVA muaj peev xwm thiab NLTC ± 2 × 2.5% voltage hloov, nws ua kom ruaj khov tso zis hluav taws xob txawm tias nyob rau hauv cov khoom hloov pauv.

Ua ntej, lub tshuab hluav taws xob faib hluav taws xob tuaj yeem muab ob qho tib si -theem thiab peb-theem khoom. Kev sib txuas Dyn11 muab peb-theem plaub- xaim tawm. Ib zaug -theem loads ua haujlwm yam tsis ua rau muaj qhov tsis sib xws. Peb -theem tshuab tau txais lub zog txaus.

Thib ob, kev teeb tsa cov nroj tsuag xav tau lub peev xwm tam sim no thiab hloov tau yooj yim cable txuas. Peb cov qauv tsim suav nrog lub siab-voltage cable box muaj peev xwm ua tau raws li 16 × 1C 630 mm² XLPE / PVC tooj liab cables thiab qis-voltage tooj liab busbars rau cov ceg sib txuas, ua kom yooj yim installation thiab yav tom ntej nthuav dav.

Thaum kawg, kev lag luam kev lag luam yuav tsum tau ua kom txias txias thiab tsis muaj zog poob. Lub transformer's ONAN cua txias, tooj liab windings, thiab kua rwb thaiv tsev ua kom ntseeg tau kev ua haujlwm nyob rau hauv ib puag ncig kub ntawm -25℃txog 40℃. Nrog rau qhov tsis muaj load poob ntawm 1.94 kW, load poob ntawm 18.3 kW, thiab 5% impedance, transformer ua tiav qhov sib npaug ntawm kev ua tau zoo, kev nyab xeeb, thiab kev ua haujlwm thermal tsim nyog rau kev lag luam txuas ntxiv.

 

 

1.2 Technical Specification

2000 kVA transformer specification thiab cov ntaub ntawv

Xa rau
Asmeskas
Xyoo
2024
Hom
Kua-Immersed Type Transformer
Daim ntawv thov
Fais fab kis
Ambient kub
-25 rau 40 degree
Qhov siab
Tsawg dua los yog sib npaug li 1000m
Txuj
IEC 60076-1: 2011
Rated zog
2000KVA ua
Ntau zaus
50 HZ
Theem
peb
Hom cua txias
ONAN
Thawj Voltage
11kv ua
Secondary Voltage
0 ,433kv
Vector Group
Dyn 11
Cov khoom siv winding
Tooj
Impedance
5%
Coj mus rhaub Changer
NLTC
Tapping Range
±2*2.5%
Tsis Load Loss
1,94kv :ua
Ntawm Load Loss
18.3 kV 18
Khoom siv
Standard Configuration

 

1.3 Cov duab kos

2000 kVA transformer qhov ntev thiab cov ntsiab lus hnyav

2000 kVA distribution transformer drawing 2000 kVA distribution transformer nameplate

 

 

02 Kev tsim khoom

2.1 Core

2000 kVA distribution transformer iron core

Cov tub ntxhais laminations tau ua tib zoo xaiv hauv cov tuab kom sib npaug ntawm kev ua tau zoo thiab tus nqi, nrog cov kauj ruam - cov pob qij txha thiab cov mitered ces kaum kom txo tau qhov sib txawv ntawm huab cua thiab sib nqus tsis kam. Grain-oriented steel aligns magnetic domains rau qhov poob qis, thaum lub stacking meej ua kom txhua yam ruaj khov thiab kev vibration tsawg. Cov qauv tsim no txhawb kev txhim khu kev qha, hloov hluav taws xob zoo rau nruab nrab thiab siab -voltage transformers.

 

2.2 Cua txias

Lub tshuab hluav taws xob faib hluav taws xob muaj peb -theem tooj liab windings tsim los rau kev hloov hluav taws xob txhim khu kev qha thiab tsis muaj hluav taws xob poob. Cov windings tau raug npaj thiab insulated los tiv thaiv thermal thiab mechanical kev nyuaj siab, txhawb kev ua haujlwm tas mus li nyob rau hauv ib puag ncig kub ntawm -25℃txog 40℃. Nrog rwb thaiv tsev chav kawm A thiab Dyn11 vector pawg, cov coils ua kom ruaj khov voltage, ua haujlwm siab, thiab ua haujlwm ntev ntev hauv kev siv hluav taws xob faib hluav taws xob.

2000 kVA distribution transformer  winding

 

2.3 Tank

2000 kVA distribution transformer oil tank

Cov bushings yog nyob rau sab saum toj ntawm lub tank thiab them nrog lub thawv cable rau kev tiv thaiv. Lub thawv khaws cov bushings thiab keyboards kom tsis txhob puas thiab nag. Lub tank yog kaw thiab ntim nrog huv transformer roj. Cov roj muab rwb thaiv tsev thiab tshem tawm cov cua sov. Qhov kev tsim no ua kom lub tshuab hloov pauv muaj kev nyab xeeb, txhim khu kev qha, thiab ntev - siv tau ntev hauv kev lag luam.

 

2.4 Terminal Txee

Lub hwj chim faib transformer nta cais cov thawv rau sab siab thiab tsis tshua muaj hluav taws xob, nrog cov bushings txuas ntawm lub tank mus rau lub thawv cable kom yooj yim cable txuas. Lub siab- lub thawv hluav taws xob muaj txog li 16 × 1C 630 mm² XLPE / PVC tooj liab cables, thaum qis -voltage sab suav nrog 4 tooj liab busbars rau yav tom ntej ceg txuas. Ob lub thawv kom muaj kev nyab xeeb, txhim khu kev qha, thiab txhim khu kev qha hluav taws xob.

2000 kVA distribution transformer cable boxes

 

2.5 Kev sib dhos zaum kawg

2000 kVA distribution transformer active part

1. Winding los ua ke: Raws li kev tsim qauv, windings ntawm qhov ntau thiab tsawg tau raug mob rau hauv cov tub ntxhais transformer, nrog rau ob qho tib si thawj thiab theem nrab windings. Cov txheej rwb thaiv tsev yog muab tso rau nruab nrab ntawm cov coils.

2. Kev kho rwb thaiv tsev: Cov windings tau kho nrog cov kua roj vanish thiab ci kom ntseeg tau tias kev ua haujlwm zoo ntawm rwb thaiv tsev.

3. Kev teeb tsa ntawm lwm yam khoom siv: Roj ntsuas kub ntsuas (OTI), siab nyem valve, Buchholz relay, roj qib ntsuas, tsis muaj load kais hloov pauv, lub thawv cable, lub davhlau ya nyob twg, thiab lwm yam.

4. Cov roj filling: Sau lub tank transformer nrog cov roj insulating kom txog thaum qhov chaw sab hauv puv puv thiab cov roj qib raws li tus qauv xav tau.

 

 

03 Kev Xeem

Test Standard thiab Routine Test

IEC 60076-1-2011 Kev lees paub

Fais fab Transformers-Part 1: General

IEC60076-3-2013

Fais fab Transformers-Part 3: Rwb thaiv tsev qib, kev sim dielectric thiab kev tshem tawm sab nraud hauv huab cua

IEC 60076-7-2018

Fais fab transformers- Ntu 7 Chaw thau khoom qhia rau cov ntxhia- roj-immersed fais fab mov transformers

 

2000 kVA distribution transformer Test-1
2000 kVA distribution transformer Test-2

1. Kev ntsuas qhov sib piv ntawm qhov ntsuas hluav taws xob thiab xyuas cov theem hloov pauv
2. Kev ntsuas ntawm winding kuj
3. Txheeb xyuas cov tub ntxhais thiab thav duab rwb thaiv tsev rau cov kua immersed transformers nrog core lossis thav duab rwb thaiv tsev
4. Kev ntsuas ntawm dc rwb thaiv tsev tsis kam ntawm txhua qhov winding rau lub ntiaj teb thiab nruab nrab ntawm windings
5. Applied voltage test (av)
6. Kev ntsuas tsis muaj -load poob thiab tam sim no
7. Induced voltage withstand test (ivw)
8. Kev ntsuas luv luv -circuit impedance thiab load poob
9. Kev ntsuam xyuas cov dej ntws nrog lub siab rau cov kua -immersed transformers (tightness test)
 

 

04 Packing thiab Shipping

4.1 Ntim

Tom qab lub Hoobkas kuaj, ntws cov roj feem ntau, qhuav rau sab hauv, thiab sau nrog cua qhuav lossis nitrogen nyob rau hauv me ntsis zoo siab. Nruab ib lub ntsuas ntsuas siab thiab nyem valve kom tiv thaiv overpressure.

Tshem cov radiators, roj conservator, roj relay, thiab roj kav; ntim nyias. Flanges tag nrho cov flanges nrog bolts los tiv thaiv kev xau thaum thauj. Ntxiv cov khoom tiv thaiv kaum (ua npuas dej, yas, lossis duab los qhia) thiab qhwv lub tsev nrog zaj duab xis tiv thaiv.

Ntim lub transformer rau hauv steel -thav duab ntoo crate. Txuas cov ntsuas kev poob siab yog tias xav tau, thiab khij lub crate nrog cov cim forklift thiab nruab nrab - ntawm - ntsuas qhov ntsuas. Npog lub crate sab saum toj nrog cov dej noo- pov thawj tarp.

image021

 

4.2 Shipping

image023

Xyuas lub transformer qhov loj thiab qhov hnyav, thiab npaj ib txoj hauv kev kom tsis txhob muaj qhov siab, dav, thiab qhov hnyav. Siv tsawg- txaj lossis tsheb thauj khoom tshwj xeeb uas muaj peev xwm txaus. Kho qhov nruab nrab ntawm lub ntiajteb txawj nqus thiab ruaj lub hauv paus nrog fasteners kom raug. Siv cov hlua khi los yog cov hlua khi los ntawm qhov uas tau xaiv, zam qhov tsis muaj zog. Xauv cov khoom sab hauv thiab kaw txhua qhov rooj.

Thaum thauj, ceev ceev Tsawg dua lossis sib npaug li 60 km / h thiab qaij Tsawg dua lossis sib npaug li 15℃. Tsis txhob txav tam sim ntawd thiab vibrations. Muab cov escorts saib xyuas lub nra thiab nres thaum huab cua hnyav.
Thaum nqa, khaws cov hlua khi tsawg dua lossis sib npaug li 60 degree, siv cov kab sib kis yog tias xav tau, nqa ncaj nraim, thiab rau cov chav uas tsis muaj cov hlua sab saum toj, siv cov hlua nqa hauv qab.

 

 

05 Site thiab Summary

Qhov no 2 MVA roj-immersed transformer tau xa mus rau Asmeskas xyoo 2024. Nws yog siv rau hauv cov khoom siv roj regenerated. Nws muab lub zog ruaj khov rau cov twj tso kua mis, lub tshuab cua sov, thiab lwm yam khoom siv. Nws muaj tooj liab windings, ONAN txias, thiab Dyn11 kev twb kev txuas. Nws ua haujlwm nrog kev poob qis, kev ua haujlwm siab, thiab lub neej ntev. Nws yog tsim rau kev nyab xeeb thiab ruaj khov siv hauv kev ua haujlwm.

 