5 MVA Traction Fais Fab Transformer-22/6.6 kV|South Africa 2025

5 MVA Traction Fais Fab Transformer-22/6.6 kV|South Africa 2025

Lub teb chaws: South Africa 2025
Muaj peev xwm: 5000 kVA
Lub Zog: 22/6.6kV
Feature: nrog kub-dip galvanized radiator
Xa kev nug

 

 

Traction Power Transformer

Ua kom koj lub tsheb ciav hlau ua tau zoo. Pib nrog Traction Transformer.

 

 

01 General

1.1 Project Description

5 MVA traction transformer tau xa mus rau Canada hauv 2025. Lub zog ntsuas ntawm lub transformer yog 5000 kVA nrog ONAN txias. Thawj qhov hluav taws xob yog 22 kV nrog ± 2 * 2.5% tapping ntau yam (NLTC), qhov nruab nrab voltage yog 6.6 kV, lawv tsim ib pawg vector ntawm Dyn11.

Hauv kev teb rau cov xwm txheej xob laim (12 hauv av flashes ib square km ib xyoos twg) thiab cov tshuaj ntsev hnyav thiab muaj kuab paug hauv South Africa, nws tsim tau txiav txim siab txog kev tiv thaiv kev tiv thaiv thiab kev tiv thaiv corrosion. Cov roj tank yog ua los ntawm cov hlau phaj nrog lub thickness ntawm ntau dua los yog sib npaug li 6 hli, thiab cov phaj hauv qab thickness ncav cuag 16 hli. Lub thickness ntawm txheej nyob rau hauv cov cheeb tsam uas muaj kuab heev yog 125 microns. Tsis tas li ntawd, cov roj tank thiab lub tshuab hluav taws xob tau txais kev sib tw vuam tsim los xyuas kom muaj lub zog thiab kev sib khi ua haujlwm.

Nyob rau hauv cov nqe lus ntawm lub ntsiab functional configuration, lub transformer yog nruab nrog ib tug NLTC tsis muaj -load kais-hloov, txhawb ib tug voltage kev cai ntau yam ntawm ± 2 × 2.5% thiab featuring padlockable functionality los xyuas kom meej qhov tseeb thiab kev ruaj ntseg voltage tswj. Qhov qis-voltage winding tuaj yeem tiv taus tag nrho qhov hluav taws xob sib xyaw ua ke ntawm txog 27%, hloov mus rau qhov chaw sib txuas hluav taws xob. Lub winding muaj lub zog txhua yam txaus los tiv thaiv qhov txhaum tam sim no, thiab qhov chaw nyob muaj qhov kev tshem tawm hauv av ntawm 3500mm, ua raws li cov qauv kev ua haujlwm siab -voltage. Lub caij no, cov cuab yeej tau nruab nrog ntau yam kev tiv thaiv, suav nrog ib qho - ntab roj relay (nrog lub tswb thiab cov neeg mus ncig ua si), cov khoom siv hluav taws xob ntau dhau (nrog rau qhov ntsuas kub ntawm qhov ntsuas kub, qhov ntsuas kub mus rau qhov kub ntawm 115 degree), dial - hom roj qhov ntsuas qhov ntsuas kub (kho qhov kev sib cuag teeb tsa ntawm 90 degree), thiab lub sijhawm ua haujlwm tsis zoo ntawm lub valve. sai sai.

 

 

 

1.2 Technical Specification

5000kVA traction transformer specifications hom thiab cov ntaub ntawv ntawv

Xa rau
South Africa
Xyoo
2025
Hom
traction transformer
Txuj
IEC60076
Rated zog
5000 kVA ua
Ntau zaus
50 HZ
Theem
3
Hom cua txias
ONAN
Thawj Voltage
22kv ua
Secondary Voltage
6,6kv ua
Cov khoom siv winding
Tooj
Angular tshem tawm
Dyn 11
Impedance
7%
Coj mus rhaub Changer
NLTC
Tapping Range
±2*2.5%
Tsis Load Loss
4.4 kWm 2
Ntawm Load Loss
35 kW

 

1.3 Cov duab kos

5000 kVA traction transformer daim duab kos duab thiab loj.

Traction Power Transformer diagram Traction Power Transformer nameplate

 

 

02 Kev tsim khoom

2.1 Core

Cov tub ntxhais transformer yog lub hauv paus sib nqus Circuit Court ntawm lub traction transformer. Tsim los ntawm siab -permeability silicon steel laminations, nws ua tau zoo raws alternating sib nqus flux nrog tsawg zog poob. Qhov no yog qhov tseem ceeb rau kev txhim kho lub zog hloov pauv thiab kev ua haujlwm ruaj khov raws li qhov xav tau ntawm kev thauj mus los ntawm kev tsheb ciav hlau.

traction transformer core

 

2.2 Cua txias

continuous disc winding

Lub nruam disc winding yog ib qho tseem ceeb coil hom hauv traction transformers. Nws yog tsim los ntawm winding rectangular conductors nyob rau hauv ib tug series ntawm radial discs tsis muaj soldered pob qij txha ntawm lem. Cov txheej txheem kho tshuab muaj zog no muab qhov tshwj xeeb luv luv - lub zog hluav taws xob thiab cov cua sov kom zoo, uas yog qhov tseem ceeb rau kev ua haujlwm txhim khu kev qha nyob rau hauv qhov kev hloov pauv tsis tu ncua.

 

2.3 Tank

Lub tank ua hauj lwm raws li kev tiv thaiv enclosure thiab ib qho tseem ceeb txias system rau lub traction transformer. Nws yog mechanically robust tiv thaiv kev vibrations thiab cuam tshuam, thaum nws tsim optimizes tshav kub dissipation los xyuas kom meej cov tub ntxhais thiab windings ua hauj lwm nyob rau hauv kev nyab xeeb kub, guaranteeing kev ntseeg tau raws li xav tau kev pab cuam.

image011

 

2.4 Lub Rooj Sib Tham Kawg

railway transformer assembled

Kev sib dhos zaum kawg yog cov txheej txheem tseem ceeb ntawm kev sib koom ua ke ntawm cov tub ntxhais, windings, thiab lub tank rau hauv qhov ua tiav thiab txhim khu kev qha traction transformer. Nws ua kom muaj kev sib raug zoo ntawm cov neeg kho tshuab, kev ncaj ncees, thiab cov roj- nruj sealing, uas ua rau lub zog muaj peev xwm ntawm kev xa cov kev ua tau zoo raws li qhov xav tau ntawm kev ua haujlwm railway.

 

 

03 Kev Xeem

Lub tshuab hluav taws xob traction no tau dhau los ua cov txheej txheem niaj hnub, hom thiab kev sim tshwj xeeb kom paub tseeb tias nws cov hluav taws xob ncaj ncees, kev ua haujlwm tau zoo, thiab kev ntseeg siab ntev ntev. Cov txheej txheem kev sim nruj, suav nrog lub zog dielectric, qhov poob, qhov sib piv, rwb thaiv tsev, thiab roj- hauv - roj tshuaj ntsuam xyuas, lees paub lub tsev tag nrho ua raws li kev ua tau zoo thiab nws qhov kev npaj rau kev thov kev pabcuam kev tsheb ciav hlau.

railway transformer test
Traction Power Transformer test

 

 

04 Packing thiab Shipping

4.1 Ntim

Lub ntim ntawm lub traction transformer yog engineered rau siab tshaj plaws kev tiv thaiv thaum lub sij hawm thauj mus los thiab cia. Siv lub hauv paus ruaj khov, huab cua tsis zoo nrog kev kho kom haum, nws ua kom muaj kev ncaj ncees ntawm lub tsev tiv thaiv kev sib tsoo, kev vibrations, thiab ib puag ncig, lav kev nyab xeeb tuaj txog ntawm qhov chaw teeb tsa.

 safe arrival

 

4.2 Shipping

international sea transit

Kev xa khoom ntawm lub tshuab hluav taws xob traction no tau ua tiav raws li CIF (Cov Nqi, Kev Pov Hwm, thiab Kev Xa Khoom) cov lus, muab qhov chaw nres nkoj dav - rau - chaw nres nkoj kev daws teeb meem. Peb lub luag haujlwm suav nrog tag nrho cov txheej txheem ntawm kev xa cov chav nyob nyab xeeb mus rau Port of Durban, South Africa. Qhov no suav nrog kev tswj hwm kev lis kev cai xa tawm, kev ruaj ntseg cov kev pabcuam hauv hiav txwv freight, thiab npaj tag nrho cov ntawv pov hwm thauj khoom, nrog rau tag nrho cov nqi cuam tshuam. Txoj hauv kev no muab cov neeg siv khoom muaj txiaj ntsig zoo thiab txo qis kev pheej hmoo, kom ntseeg tau tias cov cuab yeej tseem ceeb tau tswj hwm los ntawm peb thoob ntiaj teb kev hla hiav txwv mus txog thaum nws tawm ntawm qhov chaw nres nkoj.

 

 

05 Site thiab Summary

Ntawm lub hauv paus ntawm lub ntiaj teb lub hwj chim, kev ruaj ntseg thiab kev ua tau zoo yog kev mus mus ib txhis. Peb cov traction transformers tsis yog tsuas yog cov khoom siv meej uas hloov hluav taws xob rau hauv lub zog muaj zog, tab sis kuj yog lub hauv paus pob zeb uas muaj kev nyab xeeb, sijhawm sijhawm thiab kev ntseeg siab. Los ntawm lub tswv yim tsim thawj zaug mus rau qhov kev sim nruj kawg, peb qhov kev ua tiav tsis tu ncua ntawm kev ua tau zoo hauv txhua qhov kev nthuav dav tsuas yog los xyuas kom meej tias hauv txhua qhov pib- nce thiab txhua txoj kev, peb tuaj yeem muab kev txhawb nqa ntsiag to tsis tau muaj zog.

Kev xaiv peb cov khoom txhais tau tias koj tau xaiv ib tus neeg koom tes ntev ntev -. Peb cog lus tias yuav tsav lub neej yav tom ntej ntawm kev thauj mus los niaj hnub ua ke nrog koj los ntawm kev siv thev naus laus zis, txhim khu kev qha zoo thiab tag nrho - cov kev pabcuam ib puag ncig, ua rau txhua qhov kev sib txuas muaj zog.

traction transformers

 

Cim npe nrov: traction fais fab transformer, chaw tsim tshuaj paus, tsum, nqe, nqi

Xa kev nug