50 KVA Transformer Ntawm Utility Ncej-4.16 / 0.6 KV|Canada 2026
Muaj peev xwm: 50kVA
Qhov hluav taws xob: 4.16-0.6Y / 0.347 kV
Feature: nrog lub siab nyem valve
Jiangshan Scotech Electrical Co., Ltd yog ib qho ntawm feem txhim khu kev qha manufacturers thiab lwm tus neeg ntawm 50 kva transformer ntawm hluav taws xob ncej-4.16/0.6 kv|canada 2026 hauv Suav teb. Thov koj xav tias dawb mus yuav cov khoom lag luam raug nqi muag ntawm no thiab tau txais daim duab kos los ntawm peb lub hoobkas. Tiv tauj peb kom paub meej ntxiv.

Lub zog tsis ua haujlwm, ua haujlwm siab - ncej mounted transformer.
01 General
1.1 Project Description
Xyoo 2026, Canadian hluav taws xob faib hluav taws xob tau mus txog rau SCOTECH nrog ib qho kev xav tau tshwj xeeb: kev ua haujlwm siab, kev ua haujlwm siab ib theem ncej mounted transformer uas yuav ua tau raws li CSA C2.2 06 cov qauv thiab ua kom ntseeg tau thoob plaws Canada cov huab cua sib txawv. Lawv cov phiaj xwm nthuav dav hauv lub network xav tau lub tshuab hloov pauv nrog cov pov thawj ua raws, kev tswj hwm qhov hloov pauv tau yooj yim, thiab cov nqi ua haujlwm qis hauv lub neej.
Tom qab kev tshuaj xyuas tag nrho, lawv xaiv peb 50 kVA ib theem ncej mounted transformer, engineered thiab sim rau CSA C 2.2 06 (tus qauv tseem ceeb rau Canadian tis transformers). Chav tsev muaj qhov tseem ceeb ntawm qhov hluav taws xob ntawm 4.16 kV nrog qhov tawm ntawm qhov hluav taws xob hloov hluav taws xob muab ± 2 × 2.5% kev hloov kho, thiab qhov hluav taws xob thib ob ntawm 0.6Y / 0.347 kV (vector pab pawg Ii6), zoo kawg nkaus kev koom ua ke rau hauv lawv 60 Hz system. Nrog ONAN txias, aluminium windings, tag nrho ntim me me steel tank, thiab ntxhia roj rwb thaiv tsev, lub transformer ua kom muaj kev saib xyuas tsawg thiab ruaj khov txawm tias nyob hauv qhov chaw txias sab nraum zoov.
Kev siv hluav taws xob tau zoo siab tshwj xeeb los ntawm nws qhov kev ua tau zoo ntawm 98.84% thiab qis impedance ntawm 2%, uas txhais ua kev txuag hluav taws xob tseem ceeb tshaj li kaum xyoo ntawm kev pabcuam. Txhua qhov kev ntsuam xyuas niaj hnub- piv, polarity, tsis muaj qhov poob, impedance, thiab induced voltage- tau ua raws li CSA cov cai, thiab xaiv hom kev xeem (kub nce, impulse, luv luv Circuit Court) kuj muaj raws li qhov kev thov. Lub compact, lub teeb yuag tsim (249 kg tag nrho qhov hnyav, 72 L roj) yooj yim ceev, nqi zoo ncej mounting, txo lub sij hawm installation thiab nqi zog.
Qhov kev xa khoom tiav no qhia txog SCOTECH lub peev xwm xa CSA tau ntawv pov thawj, kev cai hloov pauv hloov pauv uas ua tau raws li qhov xav tau nruj ntawm Canadian cov khoom siv hluav taws xob. Peb tseem yog ib tus neeg koom tes txhim khu kev qha rau cov phiaj xwm kev faib khoom thoob plaws tebchaws Canada, ua kom muaj kev ua raws cai, ua haujlwm ntev, thiab kev ua haujlwm ntawm ntug dej hiav txwv mus rau ntug dej hiav txwv.
1.2 Technical Specification
50 kVA ncej mounted transformer specifications hom thiab cov ntaub ntawv ntawv
|
Xa rau
Canada
|
|
Xyoo
2026
|
|
Hom
Ncej mounted transformer
|
|
Txuj
CSA C2.2-06
|
|
Rated zog
50 kVA
|
|
Ntau zaus
60 tzs
|
|
Theem
1
|
|
Polarity
Ntxiv
|
|
Hom cua txias
ONAN
|
|
Thawj Voltage
4.16 kv
|
|
Secondary Voltage
0.6Y/0.347 kV
|
|
Cov khoom siv winding
Aluminium
|
|
Angular tshem tawm
Ib 6
|
|
Impedance
2%
|
|
Kev ua tau zoo
98.84%
|
|
Coj mus rhaub Changer
±2*2.5%
|
|
Tsis Load Loss
0.145 kWm
|
|
Ntawm Load Loss
0, 657 kWm
|
1.3 Cov duab kos
50 kVA ncej mounted transformer daim duab kos duab thiab loj.
![]() |
![]() |
02 Kev tsim khoom
2.1 Core

Lub transformer siv lub siab permeability grain oriented silicon steel qhov txhab core, uas muab ib tug nruam sib nqus flux txoj kev thiab ho txo tsis muaj load poob. Ntsuas ntawm 100% qhov ntsuas hluav taws xob, qhov poob ntawm qhov tseem ceeb tsuas yog 0.108 kW nrog rau qhov kev tawm dag zog tam sim no ntawm 0.29% - ob qho tib si zoo hauv qab CSA qhov siab tshaj plaws txwv. Qhov kev tsim cov tub ntxhais kawm qib siab no ncaj qha ua rau lub tsev ua haujlwm tau zoo thiab ruaj khov voltage tswj.
2.2 Cua txias
Aluminium windings yog teem nyob rau hauv ib tug concentric configuration, nrog rau qhov tsawg voltage (LV) winding muab tso rau ib sab ntawm cov tub ntxhais thiab lub high voltage (HV) winding qhov txhab nyob rau hauv nws, kom ntseeg tau zoo flux coupling thiab tsis tshua muaj to reactance. HV winding suav nrog cov kais dej rau ± 2 × 2.5% tawm ntawm kev hloov hluav taws xob hloov hluav taws xob. Tus qauv tsim ua tiav qhov impedance ntawm 2.29% thiab tswj qhov kub thiab txias (nruab nrab Tsawg dua lossis sib npaug rau 65 degree, qhov kub tshaj plaws tsawg dua lossis sib npaug li 80 degree) zoo hauv CSA cov cai.

2.3 Tank

Lub transformer yog nyob rau hauv ib tug tag nrho kaw me me steel tank nrog lub teeb grey corrosion resistant txheej (Munsell 5BG7.0 / 0.4, ANSI 70), muab kev tiv thaiv huab cua zoo rau Canada cov huab cua sib txawv. Kev tsim vaj tse kaw tshem tawm qhov xav tau ntawm cov roj sampling ib ntus lossis sau rau hauv cov xwm txheej ib txwm muaj. Ob lub welded lifting lugs yog muab rau kev ruaj ntseg tuav, thiab lub tank yog xau kuaj los lav kev ruaj ntseg sealing. Tag nrho qhov hnyav yog 249 kg nrog roj ntim ntawm 72 L.
2.4 Siab Relief Valve
Lub nplhaib rub hom siab nyem valve yog mounted ntawm lub tank npog raws li tus qauv. Nws cia li qhib thaum lub siab sab hauv mus txog qib preset (feem ntau 0.03 MPa lossis 0.06 MPa, customizable) thiab kaw thaum lub siab poob qis dua qhov pib. Phau ntawv rub lub nplhaib tso cai rau cov neeg ua haujlwm kom muaj kev nyab xeeb ntawm qhov cua thaum xav tau. Cov cuab yeej no ua kom muaj kev tiv thaiv overpressure sai, txhim kho ob qho tib si transformer thiab cov neeg ua haujlwm kev nyab xeeb.

2.5 Tsis Muaj Load Kais Changer

Lub transformer yog nruab nrog ib tug de energized (tawm Circuit Court) kais changer nyob rau hauv lub tank cover, muab ib tug kev cai ntau yam ntawm ± 2 × 2.5% ntawm HV winding. Tag nrho cov kais hloov pauv yuav tsum tau ua nrog lub transformer de energized, ua kom muaj kev nyab xeeb thiab txhim khu kev qha. Lub kais hloov pauv tau haum nrog lub npog los nag rau sab nraum zoov kom ruaj khov thiab raug txheeb xyuas thaum lub sijhawm ua haujlwm niaj hnub, nrog qhov sib txawv ntawm qhov sib txawv nyob rau hauv ± 0.5% ntawm tus thawj coj tapping.
2.6 Grounding Terminal
Ib qho kev qhia hauv av muaj xws li ob qho tib si hauv av thiab lub tank grounding. Lub rooj sib txoos hauv av muaj xws li stainless hlau ib lub qhov spade hom lug ( tooj dag forging), Φ11 eyebolt (aluminium bronze), thiab stainless hlau hardware (ANSI 304). Qhov kev npaj no yog ntsuas kom nqa tag nrho cov luv luv tam sim no rau 4 vib nas this tsis muaj cua sov ua rau mob, ua kom muaj kev nyab xeeb tam sim no dissipation thiab lub sij hawm ntev corrosion kuj nyob rau hauv ib puag ncig sab nraum zoov.

03 Kev Xeem
Txhua lub tshuab hloov pauv tau dhau los ua qhov kev sim ua txhua hnub raws li CSA C2.2 06 thiab CSA C802.1 13. Cov txheej txheem sim ua ntu suav nrog:
• Kev ntsuas ntsuas - DC winding tsis kam ntawm txhua tus kais dej
• Kev Ntsuas Qhov Ntsuas - qhov ntsuas qhov ntsuas qhov ntsuas ntawm txhua qhov kais dej, qhov sib txawv tsawg dua lossis sib npaug li ± 0.5%
• Polarity Test – paub meej txog cov polarity ntxiv
• Tsis muaj Load Losses thiab Excitation Tam sim no – ntsuas ntawm 100% thiab 105% rated voltage
• Load Losses thiab impedance Voltage - kho rau 85 degree, kam rau ua ± 15%
• Applied Voltage Test – HV 19 kV / LV 10 kV rau 60 s
• Induced Voltage Withstand Test – 2Ur, 150 Hz, 48 s
• Kev ntsuas kev tiv thaiv rwb thaiv tsev
• Kev Xeem Leak - 20 kPa rau 12 h, tsis muaj dej xau
• Roj Test – dielectric zog, noo noo cov ntsiab lus, dissipation yam, thiab roj chromatography
Kev xaiv hom kev xeem (kub nce, impulse, luv luv Circuit Court, thiab lwm yam) muaj nyob rau ntawm kev thov. Tag nrho cov ntaub ntawv ntsuam xyuas yog serialized thiab tag nrho traceable.


04 Packing thiab Shipping
4.1 Ntim

Txhua lub tshuab hloov pauv tau ruaj khov rau lub luag haujlwm hnyav ntoo hlais lossis pallet, nrog rau tag nrho cov bushings thiab terminals tiv thaiv los ntawm lub kaus mom lossis npog. Lub tank yog ntim nrog cov roj ntxhia thiab kaw ua ntej xa khoom xa tuaj. Cov npe ntim khoom thiab cov ntaub ntawv xa khoom tau suav nrog, thiab cov ntawv xaiv bar coding ib qho ANSI/IEEE C57.12.35 tuaj yeem muab tau raws li kev thov.
4.2 Shipping
Transformers raug xa tawm los ntawm peb lub chaw nyob hauv Jiangshan, Tuam Tshoj, nyob rau hauv txoj hauj lwm ncaj ncees los tiv thaiv cov roj to thiab sab hauv. Lub compact tsim (249 kg tag nrho qhov hnyav) txo cov nqi thauj khoom thiab ua kom yooj yim tuav. Tag nrho cov khoom xa tuaj yog nrog los ntawm cov ntaub ntawv ua tiav, suav nrog cov ntaub ntawv xeem thiab cov lus qhia kev teeb tsa. SCOTECH tswj xyuas kev thauj mus los kom ntseeg tau tias xa khoom raws sijhawm rau Canadian cov chaw nres nkoj nrog lub sijhawm sib tw.

05 Site thiab Summary
SCOTECH 50 kVA ib theem ncej mounted transformer (CSA certified) - zoo tagnrho rau kev faib tes hauj lwm, hluav taws xob nyob deb nroog, subdivisions, ua liaj ua teb irrigation, thiab lub teeb coj mus muag chaw. Peb muab kev tsim qauv tsim, kev txhawb nqa, thiab txhim khu kev qha tom qab muag kev pabcuam. Tiv tauj peb los tham txog koj cov kev xav tau. Lub hwj chim Canada lub neej yav tom ntej - ntseeg tau, ua tau zoo, thiab ruaj khov.

Cim npe nrov: 50 kva transformer ntawm hluav taws xob ncej-4.16/0.6 kv|canada 2026, Tuam Tshoj 50 kva transformer ntawm hluav taws xob ncej-4.16/0.6 kv|canada 2026 manufacturers, lwm tus neeg, Hoobkas
You Might Also Like
100 kVA Ncej Mounted Transformer-7.97/0.12*0.24 kV|C...
167 kVA Ncej Mounted Distribution Transformer-24.94/...
25 KVA Hluav Taws Xob Ncej Transformer-7.2/0.12*0.24...
25 KVA Transformer Ntawm Ib Ncej-44/0.347 KV|Canada ...
50 KVA Transformer Fais Fab Ncej-13.8/0.24/0.12 KV|G...
100 KVA Transformers Ntawm Lub Hwj Chim-13.8 / 0.347...
Xa kev nug