25 KVA Ib Theem Distribution Transformer-13.8*6.9/0.12*0.24 KV|Jamaica 2026
Peev xwm: 25kVA
Qhov hluav taws xob: 13.8 * 6.9-0.12 * 0.24V
Feature: nrog IFD
Jiangshan Scotech Electrical Co., Ltd yog ib qho ntawm feem txhim khu kev qha manufacturers thiab lwm tus neeg ntawm 25 kva ib theem faib transformer-13.8*6.9/0.12*0.24 kv|jamaica 2026 hauv Suav teb. Thov koj xav tias dawb mus yuav cov khoom lag luam zoo rau kev muag ntawm no thiab tau txais cov duab kos los ntawm peb lub hoobkas. Tiv tauj peb kom paub meej ntxiv.

25 kVA ib theem pad mount tis transformer engineered rau txhim khu kev qha underground hluav taws xob faib
01 General
1.1 Project Description
Ib tug neeg Jamaican tau xaj 16 ib-theem pad-mounted transformers, ua tiav rau lub Cuaj Hli 2026. Cov khoom siv suav nrog plaub qhov kev ntsuas: 25 kVA, 50 kVA, 100 kVA, thiab 167 kVA. Thawj qhov hluav taws xob yog 13.8 kV lossis 13.8 / 6.9 kV, nyob ntawm qhov ntsuas qhov ntsuas hluav taws xob. Tag nrho cov chav nyob muaj dual-voltage theem nrab ntawm 0.24 / 0.12 kV.
Lub 25 kVA ib-theem voj-feed ncoo-mounted transformer nta ib tug dual-voltage thawj tsim. Nws thawj voltage yog 13.8 / 6.9 kV, nrog rau theem nrab voltage ntawm 0.24 / 0.12 kV. Lub transformer yog tsim los rau underground utility faib. Nws siv cov polarity rho tawm thiab tooj liab windings rau txhim khu kev qha fais fab.
Lub ONAN txias system siv cov roj ntxhia ua cov kua insulating. Tsis muaj load poob yog 0.078 kW, thaum lub load poob yog 0.165 kW.
Ob lub 300 A loadbreak keyboards muab kev nyab xeeb hloov thiab kev sib cais. Bayonet thiab thaub qab tam sim no-limiting fuses muab kev sib koom tes tiv thaiv kev ua txhaum. Ib qho IFD muab kev tshawb nrhiav qhov txhaum sab hauv rau kev tiv thaiv ntxiv. Ib txoj hauj lwm tsib NLTC muab ± 2 × 2.5% tapping ntau rau kev hloov pauv voltage.
1.2 Technical Specification
25kVA Tib theem ncoo mounted transformer specification thiab cov ntaub ntawv ntawv
|
Xa rau
Jamaica
|
|
Xyoo
2026
|
|
Hom
Ib theem pad mount transformer
|
|
Txuj
IEEE Std C57.12.38-2014
|
|
Rated zog
25KVA
|
|
Ntau zaus
50HZ
|
|
Polarity
Kev rho tawm
|
|
Theem
Ib leeg
|
|
Hom cua txias
ONAN
|
|
Ua kua insulating
Mineral Roj
|
|
Thawj Voltage
24 GrdY/13.8*12GrdY/6.9 kV
|
|
Secondary Voltage
0.24 / 0.12 kV
|
|
Cov khoom siv winding
Tooj
|
|
Impedance
2.5%
|
|
Coj mus rhaub Changer
NLTC
|
|
Tapping Range
±2*2.5%
|
|
Tsis Load Loss
0.078 kW
|
|
Ntawm Load Loss
0.165 kW
|
|
Khoom siv
Standard Configuration
|
1.3 Cov duab kos
25kVA Ib theem ncoo mounted transformer kos duab thiab nameplate
![]() |
![]() |
02 Kev tsim khoom
2.1 Cua txias


Tag nrho cov transformers nyob rau hauv no batch siv tooj liab windings.
2.2 Tank
Cov roj tank yog ua los ntawm cov qib siab-cov pa roj carbon steel phaj, muaj peev xwm tiv taus lub siab sab hauv tsis pub tsawg tshaj 70 kPa yam tsis muaj dej. Cov txheej txheem vuam ntawm cov roj tank ua tau raws li AWS tus qauv. Uas yog hais tias, cov welds raug du thiab nruam, tsis muaj vuam deformation los yog ntse npoo.

2.3 Insulating kua
Cov roj insulating yog ib puag ncig tus phooj ywg insulating kua uas tsis muaj PCBs thiab ua tau raws li qhov yuav tsum tau muaj ntawm Ontario Hydro Specification M-104M-85. Tsis tas li ntawd, nyob rau hauv kev thauj mus los, nws lub zog dielectric tsis tsawg dua 40 kV thaum kuaj nrog 2 hli electrode sib nrug.
2.4 High-voltage bushings

Nruab nrog ob 200 A high-voltage bushing bases thiab pub-thru bushings. Lub high-voltage nruab nrab taw tes yuav tsum tau reliably txuas nrog rau hauv av clamping qauv los yog lub tank lub cev; Qhov kev sib txuas no yuav tsum tsis muaj kev ywj pheej ntawm lwm cov hluav taws xob txuas hluav taws xob.
2.5 Tsawg-Voltage Terminals
Qhov no batch ntawm ib-theem pad-mounted faib transformers siv tsawg-voltage tin-plated tooj liab spade-zoo li tus terminals, drilled rau NEMA qauv.
Nws tuaj yeem tiv taus qhov nruam ntsug ntawm lub zog ntawm 750 N ntawm lub qhov txuas sab nraud yam tsis muaj qhov to, puas, lossis deformation mus tas li. Nws yuav tsum tsim nyog rau ob qho tib si tooj liab thiab txhuas tus neeg xyuas pib sib txuas thiab ua tau raws li qhov kev hloov pauv ntawm qhov kev ua haujlwm puv sijhawm tam sim no.

2.6 Accessories


03 Kev Xeem
Kev xeem Standard



Cov qhabnias xeem


04 Ntim thiab thauj


05 Site thiab Summary
Tsim los rau kev txhim khu kev lag luam hauv av, qhov no 25 kVA ib theem pad mount tis transformer muab kev sib txuas ntawm lub voj voog, kev hloov pauv, kev tiv thaiv fuse, thiab cov kev xaiv hloov tau yooj yim. SCOTECH muaj kev tsim kho thiab cov khoom siv kom haum rau cov khoom siv sib txawv thiab cov kev xav tau ntawm qhov project.
Cim npe nrov: 25 kva ib theem faib transformer-13.8*6.9/0.12*0.24 kv|jamaica 2026, Tuam Tshoj 25 kva ib theem faib transformer-13.8*6.9/0.12*0.24 kv|jamaica 2026 manufacturers, lwm tus neeg, Hoobkas
You Might Also Like
50 kVA Pad Mounted Transformer-24.94/0.24*0.12 kV|Sa...
100 kVA Pad Mount Transformer-24/0.24 kV|Jamaica 2024
167 kVA Pad Mount Transformer-24 * 12/0.24 kV|Jamaic...
50 kVA Ib Phase Pad Mounted Distribution Transformer...
25 kVA Pad Mounted Transformer-24 * 12/0.24 kV|Jamai...
225 KVA Single Phase Transformer Pad-4.8/0.12/0.24 K...
Xa kev nug