SCOTECH Cordially Caw Koj Mus Rau DTECH 2026 Ntawm Lub Rooj Muag Khoom UL200

Feb 04, 2026

Tso lus

Transformer chaw tsim tshuaj paus SCOTECH cordially caw koj tuaj koom peb ntawm DTECH 2026 hauv San Diego los tshawb nrhiav lub zog tshiab thiab txhim khu kev qha ua ke.

202602020404598371
Cov ntsiab lus ntawm qhov xwm txheej:

📌 Kev tshwm sim:TIAB SA 2026

📅Hnub tim:Lub Ob Hlis 2-5, 2026

📍 Qhov chaw:San Diego, California, USA

🎪SCOTECH Lub Rooj Muag Khoom:UL 200

Peb pab pawg yuav tos ntawmLub rooj muag zaub UL200los nthuav qhia peb cov khoom lag luam nthuav dav thiab sib tham txog cov kev daws teeb meem uas haum rau koj cov kev xav tau tshwj xeeb.

 

 

Ntawm qhov kev nthuav qhia, koj yuav pom SCOTECH tag nrho cov khoom lag luam tseem ceeb tsim los rau ntau hom kev siv:

2026

Ncej Mounted Transformer

  • Ib Theem Ncej Mounted Transformer: Lub teeb yuag thiab tus nqi- siv tau zoo tagnrho rau cov kab hluav taws xob nyob deb nroog thiab suburban.
  • Peb Theem Ncej Mounted Transformer: Muab kev ruaj khov thiab muaj txiaj ntsig nyiaj siv ua haujlwm rau kev lag luam thiab thaj chaw nyob.

 

Pad Mounted Transformer

  • Ib Theem Pad Mounted Transformer: Compact thiab nyab xeeb, dav siv nyob rau hauv cov neeg nyob ib puag ncig thiab kev faib hauv nroog.
  • Peb Theem Pad Mounted Transformer: Tag nrho cov qauv tsim muab kev ruaj ntseg sab nraum zoov ncoo -mounted lossis subsurface installation daws teeb meem.

 

Kev faib tawm Transformer

  • Unit Substation Transformer: Ua raws li cov khoom siv tseem ceeb hauv cov chaw ua haujlwm substations, ua kom muaj hluav taws xob hloov pauv thiab kev faib tawm.
  • Roj -Immered Distribution Transformer: Paub txog kev ua kom sov zoo dua thiab muaj kev ntseeg siab, haum rau ntau yam siab -load scenarios.
  • Compact substation: Integrated tsim txuag chaw thiab tso cai rau kev xa tawm sai thiab siv hluav taws xob zoo.

 

Fais fab Transformer

  • Me / Nruab Nrab / Loj Fais Fab Transformer: Npog txhua qib los ntawm cov kab sib faib hauv cheeb tsam mus rau siab -voltage transmissions networks, kom ntseeg tau tias muaj kev nyab xeeb thiab ruaj khov ntev - kis tau tus mob.

 

Qhuav hom Transformer

  • Cast Coil Dry Type Transformer: Hluav taws kub- tiv taus, ya raws- pov thawj, thiab yooj yim los tswj, ua rau nws zoo tagnrho rau kev siv sab hauv tsev xws li khw, tsev kho mob, thiab cov tsev siab - nce siab.
  • Vacuum Pressure Impregnated (VPI) Qhuav Hom Transformer: Nta zoo heev rwb thaiv tsev thiab rugged durability, haum rau xav tau kev lag luam ib puag ncig.

 

Tshwj xeeb Transformer

  • Rectifier transformer: Cov khoom siv tseem ceeb tshwj xeeb tsim los muab DC lub zog rau electrolysis, kev tsheb ciav hlau, thiab kev siv zoo sib xws.
  • Rauv Transformer: Muab cov tswv yim ruaj khov thiab kho tau lub zog rau siab - lub zog arc rauv hauv metallurgy, tshuaj, thiab lwm yam lag luam.
  • Earthing Transformer: Ua kom muaj txiaj ntsig zoo tsim qhov nruab nrab kom ntseeg tau tias kev ua haujlwm ruaj ntseg hauv daim phiaj xwm tsis raug.
  • Traction Transformer: Ua tau raws li cov kev xav tau tshwj xeeb ntawm cov khoom siv hluav taws xob ntawm cov hluav taws xob railways thiab cov tsheb ciav hlau hauv nroog.

 

Transformer Tank

Peb tshwj xeeb hauv kev tsim thiab tsim cov khoom siab - zoo transformer tanks. Tau tshaj peb cov roj tag nrho -immersed transformers, peb cov tso tsheb hlau luam kuj muaj raustandalone muag, catering rau koj kho, hloov, lossis kev cai qhov project xav tau.

 

Txawm hais tias koj tab tom nrhiav rau cov khoom lag luam lossis tshawb nrhiav kev sib koom tes ua haujlwm, peb tos ntsoov rau hauv - sib tham tob nrog koj ntawmLub rooj muag zaub UL200los tshawb nrhiav cov cib fim rau kev sib nrig sib loj hlob.

Peb zoo siab tau ntsib koj ntawm DTECH 2026!

202602040843461398177
202602040843471399177

 

Hais txog SCOTECH

SCOTECH yog lub tuam txhab ua haujlwm siab - thev naus laus zis tsom rau R&D, kev tsim khoom, thiab kev pabcuam ntawm transformers. Peb cov khoom, muaj npe nrov rau kev ntseeg tau zoo, kev ua tau zoo, thiab kev yoog raws, ua haujlwm rau lub ntiaj teb lub zog, kev lag luam, thiab lub zog tshiab. Peb tau cog lus los tsim kom muaj txiaj ntsig ntev -lub sijhawm rau peb cov neeg siv khoom los ntawm kev tsim kho tshiab tas li.

Peb qhov chaw nyob

Tsis yog . 21 Xiezuo Road, Qinghu Street, Jiangshan City, Zhejiang Province, Suav teb

Xov tooj

+86-13857027511

E -mail

info@scotech.com

202602021045001374177

 

Xa kev nug